For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-42 — Specific standards

Code of Ordinances, City of Meridian, Mississippi (Supp. No. 55: codified through Ordinance No. 4604, enacted October 21, 2025) · Meridian Code of Ordinances § 10-42

Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/302033d9-76b6-4f8e-b014-16bf1b411e9a

Sec. 10-42. - Specific standards.

In all areas of special flood hazard where base flood elevation data have been provided, as set forth in section 10-7, or section 10-27(9), the following provisions are required: (1) Residential construction. New construction or substantial improvement of any residential structure shall have the lowest floor, including basement, elevated one (1) foot above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of subsection (3) below. (2) Nonresidential construction. New construction or substantial improvement of any commercial, industrial, or nonresidential structure shall have the lowest floor, including basement, elevated one (1) foot above the base flood elevation. Structures located in all A-zones may be floodproofed in lieu of being elevated provided that all areas of the structure below the required elevation are watertight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamics loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the official as set forth in section 10-28(2). (3) Elevated buildings. New construction or substantial improvements of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria: 1. Provide a minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding. 2. The bottom of all openings shall be no higher than one (1) foot above grade; and 3. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwaters in both directions. b. Electrical, plumbing, and other utility connections are prohibited below the base flood elevation, unless they are designed so as to prevent water from entering or accumulating within the equipment components (floodproofed). c. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); and d. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. (4) Floodways. Located within areas of special flood hazard established in section 10-7, are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters which carry debris, potential projectiles and has erosion potential, the following provisions shall apply: a. Prohibit encroachments, including fill, new construction, substantial improvements and other developments unless certification with supporting technical data by a registered professional engineer is provided demonstrating that encroachments shall not result in any increase in flood levels during occurrence of the base flood discharge; b. If subsection (a) above is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of sections 10-41—10-44. c. Prohibit the placement of manufactured homes (mobile homes), except in an existing manufactured homes (mobile homes) park or subdivision. A replacement manufactured home may be placed on a lot in an existing manufactured home park or subdivision provided the anchoring standards of section 10-41(2) and the elevation standards of section 10-42(1) are met.

(Ord. No. 3963, § 8B, 12-7-93; Ord. No. 4569, 1-17-23)

Ask a question about Meridian law

Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.