SECTION 4.

LOCAL AMENDMENTS TO THE 2024 INTERNATIONAL BUILDING CODE. The following provisions of the 2024 International Building Code are hereby amended as follows:

A. Section [A] 101.1 – Title. These regulations shall be known as the Building Code of the City of Ocean Springs, hereinafter referred to as “this code.”

B. Section [A] 103.1 – Creation of Enforcement Agency. The Ocean Springs Building Department is hereby created and the official in charge thereof shall be known as the building official. The function of the agency shall be the implementation, administration, and enforcement of the provisions of this code.

C. Section [A] 105.2 – Work Exempt from Permit. Omit under the section entitled “Building” Item Nos. 1, 2, 4, 5, 6, and 10 completely as listed. Permits shall be required for these previously exempted items. Omit under the section entitled “Mechanical” Item No. 4 completely as listed. A permit shall be required for the previously exempted item.

D. Section [A] 114.4 – Violation Penalties. Any person who violates a provision of this code or fails to comply with any requirement thereof, or who erects, constructs, alters, or repairs a building or structure in violation of approved construction documents, directives of the building official, or permits or certificates issued under the provisions of this code, shall be subject to fines of up to five (5) times the normal permit fee.

E. Section 420.4 – Automatic Sprinkler Systems in Group R Units. See amendments to Chapter 9 for fire sprinkler requirements for Group R occupancies.

F. Section 903.2.1.2 Exception No. 2 – Fire Sprinklers Required for Group A-5. Change occupant load from 100 to 300.

G. Section 903.2.1.5 – Fire Sprinklers Required for Group A-5. Change 1,000 square feet to 5,000 square feet.

H. Section 903.2.1.6 – Fire Sprinklers Required for Assembly Occupancies on Roofs. Change occupant load from 100 to 300 for Group A-2 occupancies.

I. Section 903.2.8 – Fire Sprinklers in Group R. Add the following exceptions:

1. Fire sprinklers are not required in R-2 apartment buildings containing four (4) or fewer units and two (2) stories or less in height if a one-hour fire partition in accordance with Section 708 is provided between all dwelling units.

2. Fire sprinklers are not required in R-3 one- and two-family dwellings.

J. Section 903.2.9.4 – Fire Sprinklers Required for Group S-1 Used for Storage of Upholstered Furniture or Mattresses. Change to: used primarily for the storage of upholstered furniture or mattresses and change 2,500 square feet to 5,000 square feet.

K. Section 1015.1 – Guards. Change 72 inches to 20 feet.

L. Section 1015.2 – Required Guard Locations. Remove “equipment platforms.”

M. Section 1015.6 – Guard for Mechanical Equipment Service. Change 10 feet to 4 feet provided the walking surface is less than 20 feet above the surface below. Change 30 inches to 72 inches.

N. Section 1015.7 – Roof Access. Change 10 feet to 4 feet provided the walking surface is less than 20 feet above the surface below. Change 30 inches to 72 inches.

O. Section 1015.8 – Window Openings. Change 36 inches to 24 inches.