§ 4 — Local amendments to the 2024 International Fire Code

Ocean Springs Selected Ordinances; partial (Adopted June 4, 2026; effective July 4, 2026) · Ocean Springs, Miss., Ord. No. 2026-011, § 4 · Effective

Corpus is an independent public-information project, not the official City of Ocean Springs website. Stable reference: corpuslaw.us/code/1cea2f78-3aeb-4494-a984-409837aaab87

SECTION 4.

LOCAL AMENDMENTS TO THE 2024 INTERNATIONAL FIRE CODE. The following provisions of the 2024 Edition of the International Fire Code including Appendix Chapters as published by the International Code Council are hereby amended as follows:

A. 101.1 Title. These regulations shall be known as the Fire Code of the City of Ocean Springs hereinafter referred to as “this code.”

B. 103.1 Creation of agency. The Ocean Springs Fire Department is hereby created and the official in charge thereof shall be known as the fire code official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code.

C. 113.4 Violation penalties. Persons who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair or do work in violation of the approved construction documents or directive of the fire code official, or of a permit or certificate used under provisions of this code, shall be guilty of a misdemeanor and shall be punishable as such. Each day that a violation continues after due notice has been served shall be deemed a separate offense.

D. 114.4 Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be liable to a fine of not less than $100.00 or more than $1,000.00.

E. 1015.8 Window openings. Windows in Group R-2 and R-3 buildings including dwelling units, where the bottom of the clear opening of an operable window is located less than 24 inches (610 mm) above the finished floor and more than 72 inches (1829 mm) above the finished grade or other surface below on the exterior of the building, shall comply with one of the following:

1. Where the bottom of the clear opening of the window is located more than 72 inches (1829 mm) and less than 75 feet (22 860 mm) above the finished grade or other surface below on the exterior of the building, the window shall comply with one of the following:

1.1. Operable windows where the openings will not allow a 4-inch-diameter (102 mm) sphere to pass through the opening when the window is in its largest opened position, provided that the opening is not required for emergency escape or rescue.

1.2. Operable windows where the openings are provided with window fall prevention devices that comply with ASTM F2090.

1.3. Operable windows where the openings are provided with window opening control devices that comply with ASTM F2090. The window opening control device, after operation to release the control device allowing the window to fully open, shall not reduce the minimum net clear opening area of the window unit to less than the area required by Section 1031.3.1 for emergency escape and rescue openings.

2. Where the bottom of the clear opening of the window is located 75 feet (22,860 mm) or more above the finished grade or other surface below on the exterior of the building, the window shall comply with one of the following:

2.1. Operable windows where the openings are provided with window fall prevention devices that comply with ASTM F2090.

2.2. Operable windows where the openings will not allow a 4-inch-diameter (102 mm) sphere to pass through the opening when the window is in its largest opened position.

2.3. Window fall prevention devices that comply with ASTM F2006. F. Appendix A amendments: A101.3 Membership of board. The Building Board of Adjustment and Appeals shall serve as the board of appeals for this code and operate under the provisions detailed in the Building Code of the City of Ocean Springs. Delete in entirety Sections A101.3.1 through A101.8.