For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 340 — MIXED USE DISTRICT (MU-1)

Ridgeland Zoning Ordinance (amendments incorporated May 7, 2026); partial · Ridgeland Zoning Ordinance § 340

Corpus is an independent public-information project, not the official City of Ridgeland website. Stable reference: corpuslaw.us/code/fb50ef55-656b-4b7d-a51a-e6471b2988ff

MIXED USE DISTRICT (MU-1)

MIXED USE DISTRICT (MU-1) SECTION 340 340.01 PURPOSE AND DESCRIPTION OF THIS DISTRICT: This zoning district is intended to allow for both traditional general commercial development as well as encourage vertical and horizontal mixed use development. For purposes of this Article, horizontal mixed use means two or more different types of uses are placed next to each other, planned as a unit, and connected together with pedestrian and vehicular access. For instance, a planned subdivision containing single-family dwellings, retail development, and an office complex. For purposes of this Article, vertical mixed use means two or more different uses occupying the same building usually on different floors. For instance, retail on the ground floor and office and/or residential uses on other floor(s). Applications for development in this zoning district shall be subject to stringent site planning and aesthetically desirable design requirements. This zoning district is also intended to meet the following purposes, as applicable: (a) Encourage, protect and enhance the pedestrian environment. (b) Encourage additional street level activity. (c) Reduce automobile trips. (d) Create a “sense of place.” (e) Provide for the efficient use of land and services. (f) Allow for a mix of land uses which strengthens opportunities for economic vitality. (g) Provide for community gathering places and pedestrian/visitor amenities. (h) Establish a distinct storefront character associated with the district. (i) Provide transitions to adjacent neighborhoods and commercial areas. (j) Maintain and enhance the area’s character through design guidelines. (k) Promote innovative site design. 340.02 LAND USES PERMITTED: A. All Land Uses permitted in C-2. B. Parks, Open Spaces, and Conservation Areas. C. Accessory uses and structures associated with the use of the land as defined under Article II and subject to the regulations in Section 31.05 of this Ordinance. D. Public streets, highways, private streets and alleys. E. Home occupations in compliance with Section 35 of this ordinance.

340.03 CONDITIONAL USES AND STRUCTURES AS PROVIDED UNDER SECTION 600.09: All Petition(s) and Application(s) For a Conditional Use Permit shall include Design Guidelines in accordance with Section 340.10. A. Public or quasi-public facilities and utilities in compliance with Section 32 and other regulations of this Ordinance. B. Detached, Single-Family Residential Dwellings. C. Zero lot line dwellings. D. Patio Homes. E. Attached, Single-Family Townhouse Dwellings. F. Residential Dwelling Units in compliance with Section 340.05. G. Residential Hotel, Housing for the elderly complexes (excluding “Retirement Villages” as defined by this ordinance, which shall be zoned “Special Use” Districts only), and specialized housing to accommodate other specific populations. H. Commercial sports and recreational facilities such as swimming pools, tennis courts, and fully-enclosed facilities such as gymnasiums. I. Commercial printing facilities. J. All uses first permitted in C-2A (Excluding Restricted Uses as Defined in Article II). K. Buildings in excess of 48 feet or four stories. L. Secondary attached/detached dwelling units as defined in Article II and subject to the regulations in Section 31.06 of this Ordinance. O. All uses first permitted in C-3. P. Apartment Complexes built prior to October 1, 2016, at a maximum density of ten (10) units per acre calculated upon the total contiguous acreage owned on February 4, 2014, complete with landscaping, signage, and parking and including Multi-family dwellings. Apartment complexes regulated by this Section shall be subject to the dimensional controls and other regulations as listed in Sections 260.04, 260.05, 260.06, 260.07, 260.08, 260.09, and 260.10 of the Official Zoning Ordinance of the City of Ridgeland. Apartment complexes may also include accessory uses such as laundromats, vending machine centers, recreational buildings, swimming pools, tennis courts, fences and walls, and similar uses and structures incidental to multi-family buildings. Accessory uses and structures shall be considered an integral part

of the Apartment Complex and shall be reserved exclusively for use by residents and guests of residents of the multi-family complex. Provided, however, the provisions of Section 600.09 do not apply to this use. Q. Hotels and motels and related restaurants. New or renovated hotels and motels shall be subject to Special Use Site Plan Standards in Section 600.14.F.12. R. Conference and Convention Center Facilities. 340.04 DIMENSIONAL REQUIREMENTS FOR INDEPENDENT COMMERCIAL USES (NOT PART OF MIXED USE DEVELOPMENT): When a traditional commercial development is proposed containing only use(s) first permitted in this district then the following dimensional requirements shall be met: A. Maximum Height: 48 feet or four stories for a vertical mixed-use building, but higher buildings may be considered as a conditional use subject to the provision of Section 600.09. B. Minimum Lot Area: None. C. Minimum Lot Width: None. D. Lot Coverage, Maximum: Subject to Site Plan Review. E. Minimum Yards: 1. Front yard: Subject to Site Plan Review. 2. Side yards and rear yards: Subject to Site Plan Review. 340.05 DIMENSIONAL REQUIREMENTS FOR MIXED USE DEVELOPMENTS: The following dimensional requirements shall be observed in all mixed use developments, except where the requirement is more specifically attributed to horizontal mixed-use, or vertical mixed use, as the case may be. A. Minimum Area for Entire Development Not Containing Single-Family Attached/Detached Residential Uses: None. B. Minimum Area for Entire Development Containing Single-Family Attached/Detached Residential Dwellings: 3 acres. C. Minimum Commercial Density in Vertical Mixed Use Buildings: The ground floor of any vertical mixed use building containing residential units must have a minimum of 50% of the leasable floor area dedicated to independent commercial uses intended for public use. Permitted Commercial use area excludes lobbies, common areas, other areas dedicated to residential

leasing and management, elevators, stairs, mechanical rooms, and any space not suitable for lease as an independent commercial use. D. Minimum Heated and Cooled Floor Area Per Residential Unit in a Vertical Mixed Use Building: 1. Studio: 600 square feet minimum; Max. Occupancy: 2 2. 1 Bedroom: 750 square feet minimum; Max. Occupancy: 3 3. 2 Bedroom: 1000 square feet minimum; Max. Occupancy: 4 4. 3 Bedroom: 1250 square feet minimum; Max. Occupancy: 5 5. 4 Bedroom: 2000 square feet minimum; Max. Occupancy: 6 Note: Vertical mixed use buildings shall not contain any unit that exceeds four bedrooms. E. Maximum Building Height: 48 feet or four stories for a vertical mixed- use building, but higher buildings may be considered as a conditional use subject to the provision of Section 600.09. No parking structure shall exceed a height of the average height of adjacent existing or proposed structures on the site and on all abutting properties. F. Minimum Floor to Ceiling Height: All commercial floor space provided on the ground floor of a vertical mixed-use building shall have a minimum floor to ceiling height of Eleven (11) feet. G. Maximum Single-Family Residential: No mixed-use development shall contain more than fifty (50) percent of the total land area of the mixed-use development as single-family residential dwellings on individual lots. This percentage shall be calculated to include all land in the development occupied by individual lots including private alleys. H. Minimum Detached Single-Family Residential: If a mixed-use development is proposed to include detached single-family residential dwelling units, then the mixed-use development shall include no less than twenty (20) detached single family residential dwelling lots. I. Minimum Mixes for Mixed Use Development: For any mixed use development, as defined in Article II, a minimum of twenty-five (25) percent of the mixed use development’s total land area shall be devoted to retail/service, office, and/or civic/institutional uses. This percentage shall be calculated to include all land in the development occupied by a building, parking lot, service/refuse area, etc. which is dedicated to the retail/service, office, and/or civic/institutional use of the land.

J. Minimum Greenspace/Open Space for Mixed Use: For mixed use developments, there shall be at least twenty (20) percent of the total land area within the mixed use development that is passive or active recreation or open space. 340.06 DIMENSIONAL REQUIREMENTS FOR SINGLE-FAMILY DETACHED DWELLINGS WITHIN A HORIZONTAL MIXED USE DEVELOPMENT: When detached, single-family residential dwellings, each on their own lot, are provided in horizontal mixed-use developments, such uses shall conform to the following dimensional requirements: A. Maximum Height: 40 feet or 3 stories. B. Minimum Lot Area: 5,000 square feet. C. Minimum Lot Width: 50 feet. D. Minimum Heated Floor Area: 1,800 square feet. E. Minimum Yards: 1. Front yard: Subject to Site Plan Review. 2. Side yards and rear yards: Subject to Site Plan Review. F. Maximum Density: 6 units per acre. 340.07 GARAGE REQUIREMENTS FOR SINGLE-FAMILY DETACHED DWELLINGS WITHIN A HORIZONTAL MIXED USE DEVELOPMENT: Each detached dwelling unit on its own lot, where proposed and permitted, shall have a two-car garage which must be located to the rear of the dwelling on at least 60 percent of the units. Where garages are permitted to have their entrance in the front facing the street, the garage shall be recessed a minimum of four (4) feet from the building line. 340.08 DIMENSIONAL REQUIREMENTS FOR SINGLE-FAMILY ATTACHED TOWNHOUSE DWELLINGS: When attached, single-family residential townhouse dwellings, each on their own lot, are provided in horizontal mixed-use developments, such uses shall conform to the following dimensional requirements: A. Maximum Height: 35 feet or 2 ½ stories. B. Minimum Lot Area: 3,000 square feet. C. Minimum Lot Width: 30 feet. D. Minimum Heated Floor Area: 1,500 square feet.

E. Minimum Yards: 1. Front yard: Subject to Site Plan Review. 2. Side yards and rear yards: Subject to Site Plan Review. F. Maximum Density: 8 units per acre. 340.09 SITE PLAN REQUIRED: A site plan shall be submitted in accordance with Section 600.11 of this Ordinance. 340.10 CONCEPT PLAN AND DESIGN GUIDELINES REQUIRED: A Concept Plan and Design Guidelines shall be required to be submitted along with the Petition and Application For a Conditional Use Permit for any new mixed-use development containing any of the uses listed as Conditional (Section 340.03). The mixed-use development concept and illustrated site plan shall show the following areas of land use, as appropriate: 1. Residential neighborhoods 2. Commercial and office-professional areas 3. Civic and institutional areas 4. Vertical mixed use areas The applicant may modify the name of the use types listed above to better represent the themes of the proposed mixed-use development. The mixed-use site plan is not required to include each of these types of uses listed above; provided, however, that a mix of uses, either within a single building or on a development site, must be provided. The development guidelines shall include, but not be limited to, the following as applicable: 1. Building Placement / Massing 2. Architecture Style (Including materials and finishes) 3. Building Form and Articulation 4. Building Height 5. Parking, Parking Adjustments, and Circulation 6. Site Amenities (Including bicycle-friendly amenities) 7. Landscaping and Screening Requirements 8. Mechanical Equipment 9. Uses and Mixing of Uses 10. Compatibility with Adjacent Properties 11. Storefront Design 12. Lighting 13. Other information deemed necessary by the Director of Community Development or his designee.

340.11 PHASING AND SEQUENCING PLAN REQUIRED: A phasing and/or sequencing plan shall be submitted in conjunction with the site plan, concept plan, and design guidelines as required. The phasing plan shall illustrate the anticipated construction phasing and sequencing for the development and may be modified periodically by the applicant subject to the approval by the Mayor and Board of Aldermen. 340.12 REQUIRED LANDSCAPING FOR AREAS NOT USED FOR BUILDINGS OR OTHER STRUCTURES, PARKING, REQUIRED YARDS OR DRIVEWAYS: Developers shall provide landscaping for all portions of a lot not used for buildings or other structures, parking, required yards or driveways. All proposed landscaping shall be noted on the site plan. Maintenance of this required landscaping shall be the responsibility of the property owner, and failure to maintain the landscaping in a satisfactory manner shall constitute a violation of this Ordinance and be subject to the penalties prescribed herein. 340.13 REQUIREMENTS REGARDING EXISTING NARROW STREETS, AND PROPOSED NEW STREETS: See Subdivision and Development Review Ordinances of the City of Ridgeland. 340.14 REQUIREMENTS FOR OFF-STREET PARKING, LOADING AND ACCESS CONTROL: See Section 37 for off-street parking, loading and access control requirements. 340.15 SIGNS: See Sign Ordinance of the City of Ridgeland, Mississippi.

Ask a question about Ridgeland law

Corpus searches the Ridgeland sections it holds and shows the ones that match, with their citations. Free, no sign-in.