§ 8.1.06 — Container Pad Requirements
Code of Ordinances, City of Starkville, Mississippi; partial · Starkville Code of Ordinances § 8.1.06
Corpus is an independent public-information project, not the official City of Starkville website. Stable reference: corpuslaw.us/code/a59e31a8-e8c6-4bc0-b6b0-705a4cd34c47
8.1.06 - Container Pad Requirements
A. Front-end-loaded refuse container location requirements. No front-end-loaded refuse container shall be located within any required front or street side yard setback. No such container shall be located in any required parking space or vehicular use area, or in any required buffer yard or landscaping area. All refuse containers shall be plugged and shall utilize plastic lids. 1. Container pads. Front-end-loaded refuse container pad(s) shall be provided by the property or business owner for all front-end-loaded Containers and shall be constructed, as a minimum, concrete strength of 3,000 psi after 28 days of curing, eight inches thick with 10 by 10 wire mesh, four inches thick with number four steel reinforcing bars on eight-inch centers in each direction, or as approved by the sanitation and environmental services department head who shall find that the reduction is necessary to provide property rights enjoyed by others in the same zoning district, and will not be detrimental to public health, safety, and welfare. The concrete slab should have a minimum slope of 0.5% and a maximum slope of 10.0%. A six-foot-long approach slab of identical width, thickness, and composition to the container pad shall also be constructed adjacent and of equal slope to said pad(s). Two 36-inch-high bollards, constructed of eight-inch diameter steel pipe filled with steel-reinforced concrete shall be placed 36 inches on-center apart and one-foot on-center from the rear of the enclosure. 2. Grading and subsoil preparation. Final grading should insure the expedient removal of surface and stormwater from the proximity of the structure. The following shall apply to subsoil preparation: Undercuts must be free of any loose or relocated soils. Excessive wet or soft areas should be removed. Install imported, clean sandy clay with a unified classification of SC or CL and a plasticity index of 10 to 25. Install imported clay in two equal lifts compacted to a minimum density of 95% to achieve a minimum finished thickness of 12 inches. 3. Front-end-loaded refuse container screening requirements. Front-end-loaded refuse Containers shall be opaquely screened from view from public streets and adjacent properties, to a height of at least six feet, or six inches higher than the height of the container (whichever is higher). This screening may be achieved by a masonry wall, fencing, landscaping or by virtue of the location of the container on the building site. A combination of the above methods may also be utilized. Unscreened refuse containers currently located throughout the city shall be reviewed on a case-by-case basis by the sanitation and environmental services department head to determine appropriate screening of the container. Establishments unable to comply with this requirement shall have their situation reviewed by the sanitation and environmental services department head with appeal to the board of aldermen for the determination of the ability, utility and aesthetic impact of the compliance with the current ordinance standards.
HISTORY Amended by Ord. 2021-03 on 1/4/2022
Ask a question about Starkville law
Corpus searches the Starkville sections it holds and shows the ones that match, with their citations. Free, no sign-in.
