Section 504. For Multi-family Developments in the Multi-Family Residential (R-3),

Neighborhood Business District (C-1), and Highway Commercial (C-3) Zoning Districts. 504.1 Site Layout and Development Pattern A. Building organization. Buildings should be grouped in a way which forms a neighborhood; be organized around and to enclose open spaces; and should be oriented to perimeter or to access drives. B. Buildings may be parallel to the street if located along the street. If the building is centrally located it should be located along an area of open space. C. The buildings located on the interior of the property may be oriented perpendicular to each other. Where buildings are located parallel to each other, the setbacks should be increased by fifty percent (50%).

D. The minimum building separation shall be fifteen (15) feet. E. When a development is located adjacent to low density residential areas, small buildings or one-story end units should be located adjacent to low-density residential areas, and provide a twenty-five (25) feet setback for accessory structures adjacent to low density residential areas. F. Multi-family development should be designed to be compatible with the character of single-family residential structures within the community. G. The compatibility of multi-family developments should be determined by the consistency of the design elements, colors, materials and landscaping of the proposed buildings within existing design elements, colors, materials and landscaping of adjoining residential structures. 504.2 Architecture and Design Guidelines The building design for multi-family buildings should provide interesting and aesthetically attractive multifamily developments, which avoid monotonous, “barracks”- style buildings. This may be accomplished by multi-faceted exterior form in which articulated facades are combined with window and door placements as well as other detailing. These developments should be integrated between low-density residential areas and commercial areas, and should complement the character of the adjacent residential neighborhood. A. Building Height/Mass/Form 1. General guidelines a. Buildings should be arranged so that they are aligned parallel to a sidewalk or around common open space, such as courtyards, greens, squares, or plazas. b. Entryways should face a street, sidewalk, or common area. Buildings should not face the rear of other buildings on the same lot or parcel. c. The maximum length of the building should be one- hundred and fifty (150) feet with a maximum four (4) attached town homes. B. Architectural Details To create a definitive, consistent style among the structures within the development, design details may include: 1. Four-sided architecture, pedestrian scaled entrances. 2. Articulated fronts. 3. Windows on all sides. C. Accessory structures should be of compatible materials, scale, colors, and details as the multi-family buildings. D. Outdoor porches, patios and screened private areas are encouraged.

504.3 Vehicular and Pedestrian Access A. There should be a use of residential, collector and through-access drives to provide internal circulation and access to units. 1. Internal Drive Design a. Use parallel and perpendicular and some curvilinear streets to create blocks within the development. b. T-intersections are encouraged. c. Follow natural contours to create a natural roadway system. d. Provide a minimum width of twenty-four (24) feet for the internal drive. 2. Primary Vehicle Access a. Avoid locating the primary access for the development from a local street serving single-family residences. b. For new developments of between two hundred and three hundred and fifty units (200 to 350) units provide two (2) primary access points. c. For each additional one hundred and fifty (150) units over three hundred and fifty (350) units provide one (1) additional access point. 3. Through Access Drives: There should be no designated parking on through access drives. B. Pedestrian Access 1. On-site pedestrian access should be connected to primary entrances, parking, community amenities and service areas and to perimeter sidewalks, and other land uses. 2. There should be a connection to a perimeter walkway every one thousand three hundred and twenty (1,320) feet. C. Parking 1. Parking areas and cars should not be the dominant visual element of the site or streetscape. 2. Parking should be internal to the development or shall be perpendicular to the public or private street. 3. Parking areas and free standing parking should be a maximum of thirty percent (30%) of public street frontage. 504.4 Screening and Fencing A. Fencing and Walls. 1. Breaks in a fence should be provided for pedestrian access to adjacent sidewalks and developments. 2. Breaks should be provided to a fence every fifty (50) feet by columns, landscaping pockets, transparent sections or change in materials. 3. Setback area should be landscaped with sod, shrubs and trees with a variety of leaf size, color and texture.

B. Service Area/Utility Screening 1. Trash enclosures should be placed twenty (20) feet from the public street, sidewalk or property line and must be screened from view. 2. Mechanical equipment and utilities should be incorporated into the building design and screened from view. 504.5 Landscaping A. Landscaping Design 1. Landscaping should be utilized to define open areas and circulation routes, as well as to break up expanses of impervious coverage. 2. A variety of plant materials should be utilized, with a preference for local plants or plants which have successfully been acclimatized to the region. 3. The landscaping plan should establish a tree canopy on the internal site with the following recommended density: a. Under 4 units - 0.75 trees per density unit b. 4 units – 1 tree per density unit c. 5 units – 1 tree per 2 density units d. 6 units or more – 1 tree per 3 density units B. If the parking lot fronts a public street, the parking lot should be screened utilizing the one or more of the following, three (3) feet landscaped hedge and/or three (3) feet wall. 504.6 Lighting Developments should include both building mounted lighting and security lighting of the parking areas and pedestrian walkways. 504.7 Common Open Space A minimum of common open space should be required. A. Minimum amount required 1. Percentage of net site: under 5 units – 17% 2. Percentage of net site: 5 or more units – 13% B. Common Open space may include land that is natural, landscaped or recreational area. C. Common open space should not include private areas, public right- of-way, private streets and drives, parking areas, storage areas, parking islands, land area less than forth (40) feet wide, setbacks between buildings and from the property lines, and detention areas (with some exceptions). D. Open space dedicated for Greenways Trails linkages may be counted toward the open space requirements.

E. Open space design should be compact, contiguous, and integrated to connect with perimeter open spaces, trails, schools, shopping, etc.