§ 23-413 — Fire protection requirements
City Code, Billings, Montana (Supp. No. 67: codified through Ordinance No. 26-5937, passed October 12, 2026) · Billings City Code § 23-413
Corpus is an independent public-information project, not the official City of Billings website. Stable reference: corpuslaw.us/code/f3f05e69-c7ea-486c-a821-5878d9996914
Sec. 23-413. - Fire protection requirements.
To ensure a reasonable level of fire protection and life-safety for the public and firefighters, fire apparatus access roads and an approved water supply capable of providing the required water flow for fire protection shall be provided in accordance with this section and the adopted fire code to all premises upon which facilities, buildings, or portions of buildings are hereafter constructed or moved into the jurisdiction. (1) Definitions. Approved means acceptable to the fire department having jurisdiction. Fire department having jurisdiction means the fire department or fire district serving the area in which the subdivision is located. (2) Major, minor, and subsequent minor subdivisions. For all subdivisions, the subdivider shall provide the following minimum mechanism for fire suppression: A pressurized fire hydrant system meeting the flow requirements of the adopted fire code, National Fire Protection Association (NFPA) 1142, and the city's public utilities department rules and regulations. (3) Emergency secondary access roads. In the event that an emergency secondary access road is approved, through the variance process, as a means of providing a second access to a subdivision, as required by subsection 23-406(a)(5) of these regulations, it shall be built to the following standards: a. Emergency access roads shall be designed to a minimum unobstructed surface width of not less than twenty (20) feet and shall be constructed to support a forty (40) ton vehicle with a surface that provides all weather driving capabilities. The road shall be constructed to city standards. The emergency access road shall be maintained throughout the year including the removal of snow and ice. Where required by the fire department having jurisdiction, gates or other approved barricades shall be required at either end of the road to restrict through traffic. A sign shall be fixed to each gate in a conspicuous manner. The sign shall read "EMERGENCY ACCESS ONLY" using black letters not less than two (2) inches wide and six (6) inches high on a white retro reflective background. b. Prior to construction, a cross-sectional design of the road including location, section, surfacing, and drainage, and design of gates or barriers shall be submitted to and approved by the Billings Fire Department and the city engineer's office. The storm drain design shall accommodate runoff during a ten (10) year storm event to ensure that there is no blockage of the roadway in the event of an emergency. The drainage shall not encroach into the travel way. c. Emergency access roads will be assigned a name by city GIS/land management. In order to ensure the roads are entered into and reflected on the county GIS mapping system, the road shall be shown on the plat along with the name assigned to the road. Emergency access roads will not have conventional street signs identifying them by the assigned name. Two (2) sets of final plans showing corrections/revisions after review and approval shall be submitted to city GIS/land management. City GIS will forward one set of plans to county GIS to ensure that the emergency access road and road name are entered into the GIS mapping system.
(Ord. No. 06-5359, § 2, 2-13-06; Ord. No. 11-5543, § 5, 10-24-11; Ord. No. 24-5896, § 6, 10-28-24; Ord. No. 26-5931, § 1, 5-26-26)
Ask a question about Billings law
Corpus searches the Billings sections it holds and shows the ones that match, with their citations. Free, no sign-in.