For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 27-406 — CMU districts

City Code, Billings, Montana (Supp. No. 67: codified through Ordinance No. 26-5937, passed October 12, 2026) · Billings City Code § 27-406

Corpus is an independent public-information project, not the official City of Billings website. Stable reference: corpuslaw.us/code/35a73c98-fb0c-435a-8f37-894da8789165

Sec. 27-406. - CMU districts.

The following site and structure regulations apply to any lot in the CMU districts. Refer to section 27-403 for general regulations applicable to all districts and Table 27-400.3, below, for regulations specific to this district, keyed to illustrations in Figure 27-400(2). See article 27-1800 for definitions and information on how to measure the following regulations: Table 27-400-3. Site and Structure Regulations. CMU1 | CMU2 | REFERENCES A. | BUILDING SITING 1 | Build to Corner | Required 2 | Maximum Building Coverage (%) | 65 | 50 3 | Minimum Front Lot Line Coverage (%) | 65 | 50 | See subsection 27-406.E for allowed courtyards. 4 | Front Build-to Zone (feet) | 5 to 20 | 10 to 20 | See subsection 27-403.H for location of front and street-side frontages. See subsection 27-403.K for arterial setback regulations. See subsection 27-406.E for minimum pedestrian area. 5 | Street-Side Build-to Zone (feet) | 5 to 20 | 5 to 20 6 | Side Setback (feet) | 5 minimum; 10, if abutting N, NX, or RMH district 7 | Rear Setback (feet) | 10 minimum; 25 if abutting N, NX, or RMH district | See subsection 27-406.E for through lots. B. | PARKING SITING 8 | Surface or Accessory Parking Yard Location | Rear, internal, side | See article 27-1800 for explanation of yards. 9 | Permitted Driveway Access Location | See section 27-1305 for driveway access locations. Rear, side, or street-side facade 10 | Permitted Garage Entry Facade Location 11 | Parking Location within Building | Allowed fully in any basement and behind required occupied building space of all other stories | See Occupied Building Space regulation below in 12. See article 27-1800 for definition of basement. 12 | Occupied Building Space along Front Facade, Minimum Depth (feet) | 20 all full-story floors; not required in any basement or half story | See article 27-1800 for definition of Occupied Building Space. C. | HEIGHT 13 | Overall Stories: Maximum Height (stories) | 4; step-backs required within 50 feet of N, NX, or RMH district | See subsection 27-406.E for stepped-back stories. 14 | Ground-Story: | See subsection 27-406.E for allowable increased ground story height. Stories are measured floor to floor. Minimum Height (feet) | 12 Maximum Height (feet) | 18 15 | Upper Stories: Minimum Height (feet) | 9 Maximum Height (feet) | 12 D. | WINDOWS, DOORS, ROOF 16 | Window & Door Coverage: Ground-Story Front Facades (%) | 65 minimum between 2 and 8 feet above sidewalk | Blank wall limitations apply to front facades per article 27-1800. Subsection 27-403.H requires front facade windows to turn corners. 17 | Window & Door Coverage: All Stories Front Facades (%) | 15 minimum per story 18 | Number of Front Façade Entrances | Principal entrances 1 per every 60 feet of facade | See subsection 27-403.J for Front Entrance regulations. 19 | Permitted Roof Types | Parapet, pitched, flat; tower permitted | See article 27-1800 for definition of roof types and exception for other roof types. [image omitted; see the official code] [image omitted; see the official code] Figure 27-400(2). CMU district diagrammatic plans and elevations. E. Supplemental regulations. 1. Courtyards. One courtyard, maximum of thirty (30) percent of facade width or fifty (50) feet wide, whichever is less, may count towards the minimum primary building frontage. 2. Minimum pedestrian frontage. When any front or corner property line is within eight (8) feet or less of the back of curb, the build-to zone shall be measured from eight (8) feet off the back of curb to allow adequate pedestrian area. 3. Height step-backs at N, NX, RMH districts. Where N, NX, or RMH zoning districts abut the parcel or are located across an alley from the parcel, any story over the second story or over thirty-five (35) feet above grade shall be set back from the rear property line a minimum of fifty (50) feet. Where the ground story is setback more than ten (10) feet from the rear lot line, the frontage landscape buffer is required per article 27-1200. Refer to Figure 27-400(3). 4. Increased ground story height. Maximum ground story height in CMU2 only may be increased up to twenty-eight (28) feet with a maximum horizontal length along any primary or main parking frontage of sixty (60) feet. The 60-foot increment of increased height may occur once for every one hundred forty (140) feet of building frontage. Lower scaled commercial spaces may front the large-format space to achieve the maximum frontage and number of entrances required along the frontage. 5. Through lots. Refer to subsection 27-403.H.4. 6. Pedestrian pathway. In CMU2, direct, continuous separate pedestrian pathways are required connecting the sidewalk along the primary frontage to each shop door on the main parking lot frontage and dividing parking lots into segments no longer than three hundred (300) feet in length. The pathway shall include the following: (a) Streetscape is required along the pedestrian pathway per article 27-1200. Pavement shall be small unit pavers, concrete scored in less than four-foot increments, or other similar material approved by the zoning coordinator. (b) Perpendicular crossings of parking drives are permitted, but the pavement shall match the pathway. (c) Parallel paths to parking shall be located in a raised median or island or a protected pathway. [image omitted; see the official code] Figure 27-400(3). Height Step-Backs at N, NX, and RMH Districts.

(Ord. No. 21-5748, § 3(Exh. A), 1-25-21)

Ask a question about Billings law

Corpus searches the Billings sections it holds and shows the ones that match, with their citations. Free, no sign-in.