For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 27-903 — Entrance types

City Code, Billings, Montana (Supp. No. 67: codified through Ordinance No. 26-5937, passed October 12, 2026) · Billings City Code § 27-903

Corpus is an independent public-information project, not the official City of Billings website. Stable reference: corpuslaw.us/code/e8b2db71-5c34-4426-b1f8-397887c6ec1f

Sec. 27-903. - Entrance types.

Entrance type standards apply to the ground story and visible basement of front facades of all frontage types as defined in this section. Refer to section 27-904, Frontage types. A. General provisions. The following provisions apply to all entrance types: 1. Intent. To guide the design of the ground story of all buildings to relate appropriately to pedestrians on the street. Treatment of other portions of the building facades is detailed in each frontage type standard (refer to subsections 27-904.A through 27-904.H). 2. Applicability. The entire ground story street-facing facade(s) of all buildings shall meet the requirements of at least one of the permitted entrance types, unless otherwise stated. 3. Measuring transparency. Refer to subsection 27-1802.D for information on measuring building transparency. 4. Visible basements. Visible basements, permitted by entrance type, are optional. The visible basement shall be a maximum of one-half (½) the height of the tallest story. 5. Storefront entrance type (Refer to Figure 27-903(1)). The storefront entrance type is a highly transparent ground story treatment designed to serve primarily as the display area and primary entrance for retail or service uses. (a) Transparency. Minimum transparency is required per frontage type. (b) Elevation. Storefront elevation shall be between zero and one foot above sidewalk. (c) Visible basement. A visible basement is not permitted. (d) Horizontal facade division. Horizontally define the ground story facade from the upper stories. (e) Entrance. All entries shall be recessed from the front facade closest to the street. (1) Recess shall be a minimum of three (3) feet and a maximum of eight (8) feet deep, measured from the portion of the front facade closest to the street. (2) When the recess falls behind the front build-to zone, the recess shall be no wider than eight (8) feet. [image omitted; see the official code] Fig. 27-903(1). Storefront Entrance Type. 6. Arcade entrance type (Refer to Figure 27-903(2)). An arcade entrance type is a covered pedestrian walkway within the recess of a ground story. (a) Arcade. An open-air public walkway is required from the face of the building recessed into the building a minimum of eight (8) and a maximum of fifteen (15) feet. (b) Recessed or interior facade. Storefront entrance type is required on the recessed ground story facade. (c) Column spacing. Columns shall be spaced between ten (10) feet and twelve (12) feet on center. (d) Column width. Columns shall be a minimum of one (1) foot eight (8) inches and a maximum two (2) feet four (4) inches in width. (e) Arcade opening. Opening shall not be flush with interior arcade ceiling and may be arched or straight. (f) Horizontal facade division. Horizontally define the ground story facade from the upper stories. (g) Visible basement. A visible basement is not permitted. [image omitted; see the official code] Fig. 27-903(2). Arcade Entrance. 7. Stoop entrance type (Refer to Figure 27-903(3)). (a) A stoop is an unroofed, open platform. (b) Transparency. Minimum transparency is required per frontage type. (c) Stoop size. Stoops shall be a minimum of three (3) feet deep and six (6) feet wide. (d) Elevation. Stoop elevation shall be located a maximum of two (2) feet six (6) inches above the sidewalk without visible basement and a maximum of four (4) feet six (6) inches above the sidewalk with a visible basement. (e) Visible basement. A visible basement is permitted and shall be separated from the ground story by an expression line. (f) Entrance. All entries shall be located off a stoop. [image omitted; see the official code] Fig. 27-903(3). Stoop Entrance Type. 8. Porch entrance type (Refer to Figure 27-903(4)). A porch is a raised, roofed platform that may or may not be enclosed on all sides. (a) Transparency. (1) Minimum transparency per frontage type is required. (2) If enclosed, a minimum of forty (40) percent of the enclosed porch shall be comprised of highly transparent, low reflectance windows. (b) Porch size. The porch shall be a minimum of five (5) feet deep and eight (8) feet wide. (c) Elevation. Porch elevation shall be located a maximum of two (2) feet six (6) inches above the sidewalk without a visible basement and a maximum of four (4) feet six (6) inches above the sidewalk with a visible basement. (d) Visible basement. A visible basement is permitted. (e) Height. Porch may be two (2) stories to provide a balcony on the second floor. (f) Entrance. All entries shall be located off a porch. [image omitted; see the official code] Fig. 27-903(4). Porch Cap. B. Street facade materials. The following applies to all facades visible from any street on all frontage types with the exception of the open frontage type: 1. Permitted facade materials. Building materials that are permitted include durable, natural materials such as clay or terracotta tiles, stone, brick, stucco, concrete, and metal. Cast stone is permitted. Painted or stained wood, and burnished and/or split face colored concrete masonry units are permitted as no more than thirty-five (35) percent of street facing facade. 2. Permitted upper story facade materials. In addition to the permitted facade materials defined in subsection 27-903.B.1, exterior insulation and finishing systems (EIFS) is permitted on upper stories. 3. Materials to avoid. Building materials that are discouraged on any street facing facade include imitation materials intended to look like natural materials; sheet materials intended to look like units; and residential grade windows and doors on all frontage types except the yard frontage. 4. Prohibited materials on street facing facades. Building materials that are not permitted on building facades that are visible from any street include bricks more than 3⅝-inch in height, and untreated wood.

(Ord. No. 21-5748, § 3(Exh. A), 1-25-21)

Ask a question about Billings law

Corpus searches the Billings sections it holds and shows the ones that match, with their citations. Free, no sign-in.