Sec. 6-1662. - Flood fringe or regulated flood hazard area without a floodway.

(a) Uses allowed without permits. All uses allowed in the floodway, according to the provisions of subsection 6-1661(a) of these regulations, shall also be allowed without a permit in the flood fringe or flood hazard area without a floodway. In addition, individual or multiple family subsurface sewage disposal systems are allowed only when they are reviewed and approved under laws and regulations administered by the department of health and environmental sciences or the local health board. (b) Uses requiring permits. All uses allowed by permit in the floodway shall also be allowed by permit within the flood fringe or regulated flood hazard area with no floodway. Such uses are subject to the requirements in section 6-1661, with the exception of the encroachment limit of subsection 6-1661(b)(1)b. Instead, such uses are subject to the encroachment limits of this section. Except for artificial obstructions in subsections 6-1661(e) and 6-1662(c), all other artificial obstructions including new construction, substantial improvements, alterations to residential, and nonresidential structures including manufactured homes, and related suitable fill or excavation shall be allowed by permit and are subject to the requirements in this section and general requirements of subsection 6-1662(b)(1), with the exception of the encroachment limit of subsection 6-1662(h). (1) General requirements. a. Base flood elevation. The appropriate base flood elevation(s) shall be determined by appropriate methods and utilized in the design and layout of the project by an engineer demonstrating the appropriate design and construction criteria herein are met. Regulated flood hazard areas that do not have computed and published base flood elevations in the adopted flood hazard study referenced in division 4, Jurisdictional area, the base flood elevation must be computed as well, utilizing appropriate engineering methods and analysis. b. Flood damage. Projects must be constructed by methods and practices that minimize flood damage and are reasonably safe from flooding. c. Surface drainage. Adequate surface drainage must be provided around structures. d. Materials. Structures are reasonably safe from flooding and constructed with materials resistant to flood damage. e. Artificial obstructions. Structures or fill must not be prohibited by any other statute, regulation, ordinance, or resolution; and must be compatible with subdivision, zoning and any other land use regulations, if any. f. Anchoring. All construction and substantial improvements shall be designed and adequately anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. g. Certification. Certification by an engineer, architect, or other qualified person must accompany the application as to an encroachment analysis where required, adequacy of structural elevations, determination of the base flood elevation, floodproofing, wet floodproofing, dry floodproofing, design and construction to withstand the flood depths, hydrodynamic and hydrostatic pressures, velocities, impact, buoyancy, and uplift forces associated with the base flood. A certification is not intended to constitute a warranty or guarantee of performance, expressed or implied. h. Encroachment analysis. 1. All applications in the regulated flood hazard area without a floodway must be supported by an encroachment analysis of the proposed use, a thorough hydrologic and hydraulic analysis except as provided in following paragraph 4, subsection 1662(b)(1)h., prepared by an engineer to demonstrate the effect of the structure on flood flows, velocities and the base flood elevation; 2. The maximum allowable encroachment is certified to be at or less than one-half (0.5) feet increase to the base flood elevation unless approval of an alteration of the regulated flood hazard area pursuant to section 6-1621 and an approved FEMA conditional letter of map revision occurs before permit issuance; 3. An encroachment analysis is not required for any development in the flood fringe where an accompanying floodway has been designated within the regulated flood hazard area; and 4. Although all other development standards herein apply, a minimal or qualitative encroachment analysis may be accepted when the project or development does not require a structure, alteration of the floodplain, involve fill, grading, excavation or storage of materials or equipment and also is certified by an engineer to not exceed the allowable encroachment. i. Electrical systems floodproof. All electrical service materials, equipment and installation for uses in a regulated flood hazard area must be certified to meet the following requirements: 1. All incoming power service equipment including all metering equipment, control centers, transformers, distribution and lighting panels and all other stationary equipment must be located at least two (2) feet above the base flood elevation. 2. Portable and movable electrical equipment may be placed below the elevation of the base flood elevation, provided that the equipment can be disconnected by a single plug and socket assembly of the submersible type; 3. The main power service lines must have automatically operated electrical disconnect equipment or manually operated electrical disconnect equipment located at an accessible remote location outside the floodplain or two (2) feet above the base flood elevation; and 4. All electrical wiring systems installed below the base flood elevation must be suitable for continuous submergence and may not contain fibrous components. j. Heating and cooling systems. Floodproof heating and cooling systems for uses in a regulated flood hazard area must be certified to meet the following requirements: 1. Be installed with float operated automatic control valves so that fuel supply is automatically shut off when flood waters reach the floor level where located; 2. Have manually operated gate valves installed in gas supply lines. The gate valves must be operable from a location above the base flood elevation; 3. Be installed in accordance with the provisions of electrical systems floodproof; and 4. Have furnaces and cooling units and ductwork installed at least two (2) feet above the base flood elevation. k. Plumbing systems floodproof. Plumbing systems for uses in the regulated flood hazard area must be certified to meet the following requirements: 1. Sewer lines, except those to be buried and sealed, must have check valves installed to prevent sewage backup into permitted structures; and 2. All toilets, stools, sinks, urinals, vaults, and drains must be located so the lowest point of possible entry is at least two (2) feet above the base flood elevation. l. Structural fill floodproof. Fill used to elevate structures, including but not limited to residential, commercial, and industrial structures must be suitable and meet the following requirements: 1. The filled area is at or above the base flood elevation and extends at least fifteen (15) feet beyond the structure in all directions; 2. Fill material must be suitable fill, that is stable, compacted, well graded, and pervious, not adversely affected by water and frost, devoid of trash or similar foreign matter, tree stumps or other organic material; and is fitting for the purpose of supporting the intended use and/or permanent structure; 3. The fill is compacted to minimize settlement and compacted to ninety-five (95) percent of the maximum density. Compaction of earthen fill must be certified by a registered professional engineer; 4. No portion of the fill is within the floodway; 5. The fill slope must not be steeper than one and one-half (1½) horizontal to one (1) vertical unless substantiating data justifying a steeper slope is provided and adequate erosion protection is provided for fill slopes exposed to floodwaters. m. Wet floodproof. Building designs with an enclosure below the lowest floor must be certified to meet the following: 1. The use of the enclosure is limited to parking, loading areas, building access, and storage of equipment or materials not appreciably affected by floodwaters; 2. Materials used for walls and floors are resistant to flooding to an elevation two (2) feet or more above the base flood elevation; 3. The enclosure must be designed to equalize hydrostatic forces on walls by allowing for entry and exit of floodwaters. Opening designs must either be certified by an engineer or architect or meet or exceed the following: i. Automatically allow entry and exit of floodwaters through screens, louvers, valves, and other coverings or devices; ii. Have two (2) or more openings with a total net area of not less than one (1) square inch for every one (1) square foot of enclosed area below the lowest floor, except if the enclosure is partially sub grade, a minimum of two (2) openings may be provided on a single wall; and iii. Have the bottom of all openings no higher than one (1) foot above the exterior or interior adjacent grade or floor immediately below the openings. n. Dry floodproof. Building designs that do not allow internal flooding must be certified to meet the following: 1. Be for non-residential use only; 2. Be floodproofed to an elevation no lower than two (2) feet above the base flood elevation; 3. Be constructed of impermeable membranes or materials for floors and walls and have water tight enclosures for all windows, doors and other openings; and 4. Be designed to withstand the hydrostatic pressures and hydrodynamic forces resulting from the Base Flood and the effects of buoyancy. o. Elevation. The lowest floor elevation (including basement) must be two (2) feet above the base flood elevation. A determination of the base flood elevation shall be certified by an engineer. Elevating may be by either suitable fill, stem walls, pilings or other acceptable means; p. Enclosure. Any enclosure below the lowest elevated floor must be designed to meet the wet floodproof requirements and the enclosure floor must be at or above the base flood elevation. q. Basement. Basements are not allowed in the floodplain except where the basement floor is two (2) feet or more above the base flood elevation; r. Crawl spaces. Crawl space foundation enclosures including sub grade crawlspace enclosures below the lowest floor must meet the wet floodproof requirements and be designed so that the crawl space floor is at or above the base flood elevation. Crawl space foundations must have an inside dimension of not more than five (5) feet from the ground to the top of the living floor level and a sub grade crawlspace must also have the interior ground surface no more than two (2) feet below the exterior lowest adjacent ground surface on all sides. A sub grade foundation exceeding either dimension is a basement; s. Variance. Where strict compliance with floodproof provisions is impossible because of existing streets, utilities, lot dimensions, or additions onto existing structures, alternative fill or floodproof measures may be permitted only by variance approval; t. Manufactured home anchors. For new placement, substantial improvement or replacement of manufactured homes for residential or nonresidential use including additions, the chassis must be secure and must resist flotation, collapse or lateral movement by anchoring with anchoring components capable of carrying a force of four thousand eight hundred (4,800) pounds and as follows: 1. For manufactured homes less than fifty (50) feet long, over-the-top ties to ground anchors are required at each of the four (4) corners of the home, with two (2) additional ties per side at intermediate locations; or 2. For manufactured homes more than fifty (50) feet long, frame ties to ground anchors are required at each corner of the home with five (5) additional ties per side at intermediate points. (2) Additional requirements for residential buildings. a. New construction, alterations, and substantial improvements of residential dwellings manufactured homes, including replacement of manufactured homes, must be constructed such that: 1. Floodproofing. The lowest floor must be two (2) feet or more above the base flood elevation and cannot be wet floodproofed or dry floodproofed; 2. Enclosure. Use for a crawlspace enclosure is limited to facilitating building component access. The enclosure cannot be dry floodproofed. An attached garage must meet the wet floodproof requirements except for both the required flood openings and limits on use but the attached garage floor must be two (2) or more feet above the base flood elevation; and b. Recreation vehicles. Recreational vehicles on site for more than one hundred eighty (180) days or not ready for highway use must meet the requirements for manufactured homes for residential use. c. Non-residential building, exceptions or additional requirements. New construction, alterations, and substantial improvements of non-residential including agricultural, commercial and industrial buildings must be constructed in accordance with the following requirements: 1. Floodproof. The lowest floor of the building must be elevated two (2) feet above the base flood elevation or adequately dry floodproofed according to this section; 2. Enclosure. Enclosures below the lowest floor on elevated buildings must be wet floodproofed and the use must be limited to parking, access or storage or dry floodproofed; d. Manufactured homes. Manufactured homes proposed for use as commercial or industrial buildings cannot be dry floodproofed; and e. Agricultural structures. Agricultural structures which are not intended to be insurable, which are used solely for agricultural purposes, have low flood damage potential, which are used exclusively in connection with the production, harvesting, storage, drying, or raising of agricultural commodities including raising of livestock, and which are not intended for human habitation are exempt from the elevation requirement, dry floodproofed or wet floodproof, but shall: 1. Be located on higher ground and as far from the channel as possible; 2. Offer minimal obstruction to flood flows; 3. Be adequately anchored to prevent flotation or collapse; 4. Where electrical, heating and plumbing systems are installed, meet the floodproof requirements in this section; and 5. Meet the elevation or dry floodproof requirements if the structure is an animal confinement facility. (c) Prohibited uses. The following artificial obstructions and nonconforming uses are prohibited in the flood fringe or floodplain without a floodway of the regulated flood hazard area: (1) Solid and hazardous waste disposal and individual and multiple family sewage disposal systems unless the systems meet the local health and sanitation regulations and when permitted pursuant to these regulations and are designed to minimize or eliminate infiltration of flood waters and avoid impairment or contamination; and (2) Storage of toxic, flammable, hazardous or explosive materials.

(Ord. No. 13-5616, § 2, 10-28-13)

Ask a question about Billings law

Corpus searches the Billings sections it holds and shows the ones that match, with their citations. Free, no sign-in.