For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6-301 — Amendments and additions

City Code, Billings, Montana (Supp. No. 67: codified through Ordinance No. 26-5937, passed October 12, 2026) · Billings City Code § 6-301

Corpus is an independent public-information project, not the official City of Billings website. Stable reference: corpuslaw.us/code/dedf03bc-837d-4eb6-86df-12c6e265a23e

Sec. 6-301. - Amendments and additions.

The following indicated sections of the Uniform Building Code are amended or added as follows: (1) Section 106.2 is amended to add another exemption from a building permit: (12) Farm and ranch accessory structures such as livestock barns, hay sheds, equipment storage, agriculture fences or similar uses directly related to agricultural operations. Structures are limited to one thousand (1,000) square feet and do not include habitable structures (i.e., residence, shop). Structures must be located a minimum of twenty (20) feet from property lines and twenty (20) feet from other structures on the same lot. This does not exempt a developer from meeting local zoning standards. (2) Section 106.3.4 is amended as follows: Section 106.3.4.1 Plans and Specifications. Plans, engineering calculations, diagrams and other data shall be submitted in one or more sets with each application for a permit. The building official shall require plans, computations and specifications to be prepared and designed by an engineer or architect licensed by the state to practice as such. EXCEPTION: The building official shall waive the submission calculations, etc., if the building official finds that the nature of the work applied for is such that reviewing of plans is not necessary to obtain compliance with this code. i. The building official may accept plans, specifications and calculations which are not prepared by an engineer or architect for Group R, Division 1 occupancies not more than two (2) stories in height or having more than three thousand (3,000) square feet of floor area on a floor and for Group R, Division 3 and M occupancies of Type V Construction. Such acceptance shall not, however, waive the requirements of engineering or architectural design as may be required to comply with the general design requirements of the code. ii. Factory-built (modular) structures for which an insignia has been issued by the Building Standards Bureau, State of Montana, Building Codes Division, need not have plans and specifications submitted for that portion of the structure covered by such insignia. However, application for permit shall include submittal of plans and specifications for foundations and additions to such structures and shall include a plot plan. iii. Before a factory built structure inspected in the factory under State of Montana Factory Built Buildings Code No. 40-60-404 is placed within the City of Billings, a written permit authorizing each unit shall be obtained from the appropriate city building official. The application for permit shall include plans and specifications for foundations and additions together with a plot plan. (3) Section 1806 is amended as follows: Section 1806.1 General. Footings and foundations, unless otherwise specifically provided, shall be constructed of masonry, concrete or treated wood in conformance with Division II and all cases shall extend below the frost line. Footings of concrete and masonry shall be of solid material. Foundations supporting wood shall extend at least six (6) inches above the adjacent finish grade. Footings shall have a minimum depth below finished grade as indicated in Table 18-1-C unless another depth is recommended by a foundation investigation. Unless a foundation investigation indicates otherwise, local frost line shall be considered to be thirty-six (36) inches below grade as grade is defined in Section 208. Footings shall extend below frost line a minimum distance equal to the "thickness of footing" as specified in Table 18-1-C. EXCEPTION: Where a foundation design by an architect or engineer is not provided, footings of the minimum dimensions specified in Table 18-1-C at the perimeter of a slab on grade which do not carry a floor load need not extend below the frost line, provided that the supported structure is limited to one-story stud bearing wall construction housing a Group U, Division 1 occupancy. Such structure shall not be attached to or share a common wall with any other structure(s) unless the foundations have been designed to minimize differential vertical displacement. Structures shall not thereafter be changed in occupancy or number of stories without also meeting all of the requirements of Chapter 18 for new construction. The building official may require an inspection of existing foundations or slabs to verify any claims as to their adequacy prior to the approval of plans or issuance of a permit for change in occupancy or number of stories. (4) Section 1302.2, Section 302.1, Exterior Design Conditions table of "The Model Energy Code" is modified in the following particulars: Winter Design Dry Bulb —10°F, Dry Bulb 91° F Summer Design Wet Bulb 66°F Degree Days Heating 7,050 Degrees North Latitude 45°5'"

(Code 1967, § 21.01.020; Ord. No. 83-4519, § 1, 6-6-83; Ord. No. 86-4691, § 2, 6-2-86; Ord. No. 88-4753, § 1, 1-18-88; Ord. No. 89-4791, §§ 3, 4, 7-10-89; Ord. No. 91-4855, § 1, 1-7-91; Ord. No. 92-4905, §§ 3, 4, 7-27-92; Ord. No. 94-4961, § 5, 5-23-94; Ord. No. 00-5127, § 2, 7-10-00; Ord. No. 02-5186, § 2, 3-25-02)

Ask a question about Billings law

Corpus searches the Billings sections it holds and shows the ones that match, with their citations. Free, no sign-in.