Sec. 10.02.070. - International Mechanical Code.
A. Adopted. The International Mechanical Code, (ICC version) 2009 Edition as provided by ARM 24.301.172 (or successor provision) is hereby adopted subject to amendment or modification under section 10.02.010. The International Mechanical Code, published by the International Code Council, is a nationally recognized model code setting forth minimum standards and requirements for certain mechanical installations. B. Amendments and additions. The following is added to the most current adopted International Mechanical Code: 1. LPG appliances may be installed in single-family dwellings not withstanding the prohibition on the installation of such appliances by the UMC and the UPC provided: a. All LPG piping is pressure tested to insure it is gastight and not installed in concealed locations. Concealed LPG piping means piping and fittings which, when in place in the finished buildings, would require removal of permanent construction to gain access to the piping. Piping may be installed in an attic, under floor area, including basement or crawl space, provided this area is adequately ventilated from at least two exposed sides of the building. Each ventilation opening shall be a minimum of 36 square inches. b. The appliance is vented-type, approved by a nationally recognized testing organization, and installed in accordance with the manufacturer's recommendations. c. Automatically controlled LPG appliances shall be of the complete shut off type. Complete (100 percent) shut off means the gas to both the pilot light and the main gas burner will shut off in the event of pilot outage. d. A readily accessible and identified shut off valve controlling the flow of gas to the entire gas piping system shall be installed near the point of connection to the service piping supply connection of the LPG tank. The container service valve may be used for this purpose. e. The installer shall promptly report any accident/incident where LPG may have been a factor, or could become a contributing factor, to the building codes bureau by phone. If death or serious personal injury occurs or if property damage in excess of $500.00 results from any such accident/incident, a written report shall be prepared by the installer and presented to the bureau within 15 days of the accident/incident. f. An LPG detection/shut-off valve system shall be installed that sounds an alarm and shuts off the main gas supply in the event of the detection of LPG. The valve shall be solenoid type shut-off valve, held open when powered, and shall be located outside the building foundation.
(Code 1982, § 15.12.010; Ord. No. 1204, § 1, 1986; Ord. No. 1288, § 1, 1989; Ord. No. 1350, §§ 1, 2, 1992; Ord. No. 1389, § 8, 1994; Ord. No. 1631, § 10, 4-4-2005)
Ask a question about Bozeman law
Corpus searches the Bozeman sections it holds and shows the ones that match, with their citations. Free, no sign-in.