Sec. 38.260.140. - Windows.

A. Transparent area. The amount of transparent area on a building facade. 1. Purpose. To provide visual interest along the public realm by encouraging visual connections between the public realm and the interior of a building. 2. Applicability. a. Transparency requirements apply to all street-facing building facades of a building. b. Single-unit dwellings up to fourplexes, including townhomes and rowhomes, are exempt from the transparency requirements. 3. Standards. a. Applicable ground and upper story building facades must meet the minimum transparency of the zoning district. b. To be considered transparent area, window and door glazing must meet the following: Table 38.260.140-1. Visible Light Transmittance | External Reflectance Ground story | More than 60% | Less than 20% Upper story | More than 30% | Less than 40% c. Transparent area may be temporarily covered by operable window treatments, such as curtains or blinds. d. Muntins, mullions, window sashes, window frames, and door frames, no more than 3 inches wide are considered transparent area. [image omitted; see the official code] Figure 38.260.140-1. Windows. e. For ground stories intended to be occupied by nonresidential uses, shelving and other visual obstructions cannot be located within 5 feet of any ground story window or door counting toward transparent area, measured inward from the exterior face of the transparent area. [image omitted; see the official code] Figure 38.260.140-2. Ground story transparency. 4. Measurement. a. Ground story. (1) General. Ground story transparency is measured as a percentage, calculated as the sum of all transparent area divided by the total facade area for the ground story. (2) Commercial ground stories. (a) For ground stories intended to be occupied by nonresidential uses, facade area is measured between 0 and 12 feet above the top of the finished floor of the ground story. (b) If the ground story height is less than 12 feet, facade area is measured between the top of the finished floor of the ground story and the top of the finished floor above. [image omitted; see the official code] Figure 38.260.140-3. Ground story facade area - non-residential. (3) Residential ground stories. For ground stories intended to be occupied by residential uses, facade area is measured between 1.5 and 8 feet above the top of the finished floor of the ground story. [image omitted; see the official code] Figure 38.260.140-4. Ground story facade area - residential. b. Upper stories. (1) Each upper story facade must meet the required transparency standard independently. All facade area associated with an upper story having the same story designation (for example: 4th story) is considered part of the same upper story facade. (2) For the purpose of calculating upper story transparency, facade area is measured as the portion of a facade area between the top of the finished floor for that story to the top of the finished floor above. When there is no story above, it is measured to the top of the wall plate. [image omitted; see the official code] Figure 38.260.140-5. Upper story facade area. 5. Relief. See 38.260.140(B) B. Blank wall width. The distance between ground story windows or doors. 1. Purpose. To provide visual interest and activation along the public realm by limiting the area without visual or physical connections between the public realm and the interior of a building. 2. Applicability. Blank wall width applies to street-facing building facades between 3 feet and 8 feet from the finished ground floor elevation, measured vertically. [image omitted; see the official code] Figure 38.260.140-6. Blank wall facade area. 3. Standards. a. Window and door openings meeting the transparent area requirements on ground story facades can be separated by a distance no greater than the maximum blank wall width specified by the zoning district. For the purpose of determining blank wall width, a garage door providing access to a single vehicle parking space is considered to be a door opening which meets the transparent area requirements on a ground story facade. b. Facades that exceed the maximum allowed blank wall width may apply one or more of the following treatments and may double the maximum blank wall width standard. Small Trees | Large Trees Small trees planted between a ground story facade with no window or door openings and the public realm. | Large trees planted between a ground story facade with no window or door openings and the public realm. [image omitted; see the official code] | [image omitted; see the official code] Dimensional Standards | Dimensional Standards Ⓐ Treatment width (min percent of blank wall width) | 100% | Ⓐ Treatment width (min percent of blank wall width) | 100% Tree type | Small | Tree type | Large Ⓑ Planting frequency (min avg.) | 5 per 100' | Ⓑ Planting frequency (min avg.) | 3 per 100' Ⓒ Planting area depth (min) | 7' | Ⓒ Planting area depth (min) | 15' Living Wall | Mural A permanently fixed assembly located between a ground story facade with no window or door openings and the public realm that supports plants, their growing medium, and irrigation. | A noncommercial image attached to the blank wall. Murals must be approved by the review authority. [image omitted; see the official code] | [image omitted; see the official code] Dimensional Standards | Dimensional Standards Ⓐ Treatment area (min percent of blank facade area) | 75% | Ⓐ Treatment area (min percent of blank facade area) | 75% 4. Measurement. a. Blank wall width. Blank wall width is measured horizontally and parallel to the street lot line from edge of transparent area to edge of transparent area, and edge of transparent area to edge of the building. [image omitted; see the official code] Figure 38.260.140-7. Blank wall measurement. b. Treatment width. Minimum treatment width is measured as a percentage, calculated as the cumulative width of blank wall treatments divided by the total length of blank wall. c. Treatment area. Minimum treatment area is measured as a percentage, calculated as the cumulative area of blank wall treatments divided by the total facade area within the blank wall width. d. Planting frequency. Planting frequency is measured as a ratio of the minimum number of plants required along the total length of the blank wall width. A minimum of one plant of the required plant type must be provided regardless of the width of blank wall treatment. e. Planting area depth. Minimum planting area depth is measured as the horizontal dimension of growing medium at the narrowest point, measured perpendicular to the applicable street lot line. The planting area must be open to the sky for at least the required planting area depth. 5. Relief. a. Relief of up to 10 percent to a blank wall width dimensional standard may be granted due to preexisting natural features. b. Public or utility facilities where windows may compromise safe operations or security may be granted relief from the window transparency and the window and door opening requirements of this section.

(Ord. No. 2025-12, § 4(Exh. A), 12-16-2025)

Ask a question about Bozeman law

Corpus searches the Bozeman sections it holds and shows the ones that match, with their citations. Free, no sign-in.