For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 38.330.040 — Standards

Bozeman Municipal Code, City of Bozeman, Montana (Codified through Order No. 2026-11, adopted September 15, 2026. (Supp. No. 16, Update 1)) · Bozeman Municipal Code § 38.330.040

Corpus is an independent public-information project, not the official City of Bozeman website. Stable reference: corpuslaw.us/code/f17ac3ae-95f6-42f3-a1a6-c4824d363908

Sec. 38.330.040. - Standards.

A. Safety. All wireless facilities subject to this division must meet the following standards: 1. The structural design for all wireless facilities greater than 10 feet in height or which have more than four square feet of total antenna area must be certified by a professional structural engineer licensed to practice in the state. A building permit must be obtained prior to the installation of any facility subject to this division. 2. All wireless facilities must meet or exceed current standards and regulations of the FCC, FAA, and any other agency with the authority to regulate wireless facilities. If such standards are changed, the owner must modify the installation to comply with the new standards within six months of the effective date of the new standards or regulations unless a different implementation schedule is required by the issuing agency. 3. Wireless facilities with a base located at grade must be enclosed within a secure fence not less than six feet in height, or the tower itself must be equipped with an appropriate anti-climbing device. B. Aesthetics. 1. All wireless facilities. a. The provisions of this section may be waived by the review authority as determined by 38.700 where it has been demonstrated that the waiver will result in superior compliance with the purposes of this chapter. b. All installations must be as visually unobtrusive as is feasible. Facilities and equipment mounted on existing structures must be visually incorporated into the structure or background by the use of architectural elements, color, screening or other concealment methods. c. No exterior lighting or lighted signage is permitted. d. All structures must be constructed in conformance with the standards of the technical codes adopted in chapter 10, article 2. e. Visual screening of ground mounted equipment must be provided in all residential areas and where a facility is located within a non-residential area which is visible, from a viewpoint five feet above grade, from a residential area. Screening must provide an opaque screen within 18 months of establishment and be a minimum of four feet in height. The screening may be of landscape materials or an opaque fence which otherwise complies with this chapter. Chain link fence with slats does not meet the opacity requirement. f. Exterior façade materials and the character of equipment compounds used in residential areas must be architectural materials of similar appearance as those commonly used in the immediate area. The purpose of the requirements of this subsection may be met by providing opaque fencing or other visual screening in compliance with all other sections of this chapter, which will obscure the entire equipment compound. The screening must be in place prior to the commencement of operations of the facility. 2. Preferences. In order to justify the construction of a wireless structure, the applicant must demonstrate that higher ranking alternatives in the following hierarchy, beginning with subsection a.(1) below, do not constitute feasible alternatives. The order of preference, from most preferred to least preferred and based on technical feasibility, for new wireless facilities is: a. Facility size. (1) Micro-scale wireless facilities or colocation on existing large scale wireless facilities; (2) Small wireless facilities; (3) Large scale wireless facilities 50 feet or less in height; and (4) Large scale (Macro) wireless facilities. b. A facility meeting the definition of concealed, as defined in 38.800.200, is always preferred over a facility of the same scope which does not meet the definition of concealed. Concealed facilities may be required in historic districts and under other circumstances. c. As appropriate, the following evidence may also be submitted to demonstrate compliance with this section: (1) That no existing wireless communications facility within the search area meets the applicant's radio frequency engineering or height requirements; (2) That no structure within the search area has sufficient structural strength to support the applicant's proposed antennas or antenna arrays; or (3) That there are other verifiable limiting factors that render collocated or other more preferred options unsuitable or unreasonable. 3. Special standards. The following special standards apply as shown in Table 38.330.040-1: Table 38.330.040-1. Zoning District | Large scale | Small wireless | Micro scale | Non-broadcast | Eligible Facility Request PLI | b | b | b | - | b M-2 | b | b | b | - | b M-1 | b | b | b | - | b B-P | c | a, c | b | - | b B-3C | c | a, c | b | - | b B-3 | c | a, c | b | - | b B-2 | c | a, c | b | - | b B-2M | c | a, c | b | - | b B-1 | c | a, c | b | - | b REMU | d | a, c | b | - | b NEHMU | b | b | b | - | b R-D | d | a, c | a, b | - | b R-C | d | a, c | a, b | - | b R-B | d | a, c | a, b | - | b R-A | d | a, c | a, b | - | b Key: a = Concealed installation is required b = Wireless facilities may exceed the maximum height of a district but are subject to the limitations of this section c = The height limitation of the district may be exceeded by the least amount necessary to provide services, but only when service may not otherwise be provided by a more preferred facility as set forth above or an alternative site d = Only allowed when service may not be provided from an alternative site or a more preferred facility installation or set of installations 4. Concealed. a. Installations located within the conservation overlay district must be concealed facilities. b. A concealed wireless facility may exceed the height limitations of the district by 10 feet. 5. Small wireless facilities. All small wireless facilities established in the neighborhood conservation district must be installed in such a way as to maintain the historic or architectural character of the host site. 6. Large scale wireless facilities. No large scale wireless facility will be permitted unless the applicant demonstrates that the proposed facility cannot be accommodated on an existing structure or by placement of a smaller facility. In order to justify the construction of a large-scale wireless facility, the applicant must demonstrate that higher ranking alternatives in the hierarchy, beginning with 2.a.(1) above, do not constitute feasible alternatives. Such demonstration must be made by submission of a statement of position, qualifications and experience by a licensed radio frequency engineer; and must address the required findings of this section. a. If collocation is feasible, the owner of the large scale wireless facility must certify in writing, prior to final permit approval, that the owner will accept for colocation any FCC-licensed or licensing exempt wireless communication provider using compatible technology at reasonable and customary rates and terms up to the structural capacity to accommodate additional antennas and/or antenna arrays. Collocation may be denied based on verifiable and substantial expectations of interference from additional users. Later failure to comply with the requirements supporting colocation may result in the revocation of city approvals or other penalties stipulated by the municipal code as the requirements of the chapter will have been violated. b. The city must find the proposed guarantee, assurances or provisions for the perpetual maintenance and for removal of an abandoned large scale wireless facility to be adequate. c. A large scale wireless facility must not either: (1) Exceed 150 feet in height; or (2) When located east of the alignment of Church Avenue/Sourdough Road and west of the extended alignment of Bozeman Trail Road/Arnica Drive; (a) Exceed 100 feet in height when its base elevation is greater than 4,800 feet; (b) Exceed 40 feet in height when its base elevation is above 4,850 feet; (c) Notwithstanding the provisions of (a) and (b), these restrictions must not apply for those areas lying east of the extended alignment of Bozeman Trail Road/Arnica Drive and south of Interstate 90. d. Where multiple service providers will be utilizing the same ground area and/or support structure, a single enclosed compound must be provided to house all ground based equipment. e. Special setbacks for large scale wireless facilities must be provided and/or a design for internal structural collapse to avoid damage or injury to adjoining property or users must be provided. (1) Residential district and mixed-use district setbacks for a large scale wireless facility must be 100 percent of facility height, which may be reduced to no less than 50 percent upon the provision and approval of an engineered design, stamped by a professional structural engineer licensed to practice in the state, establishing a smaller collapse area utilizing breakpoint technology. (2) A large scale wireless facility in non-residential zones must provide a minimum setback from the property lines of 75 percent of facility height, which may be reduced to no less than 30 percent of facility height upon the provision and approval of an engineered design, stamped by a professional structural engineer licensed to practice in the state, establishing a smaller collapse area utilizing breakpoint technology. Large scale wireless facilities located within non-residential zones, but adjacent to a residential zone or residentially developed areas, must maintain a minimum setback from residential zoning or property boundaries of at least 50 percent of facility height. All installations must maintain the minimum zoning district setbacks per article 2. f. New macro wireless facilities must be designed in all respects to accommodate both the applicant's antennas and antennas for at least two additional users. A new macro wireless facility may meet this requirement by correctly sizing the foundation and other structural elements to allow the future addition of height to the structure to accommodate additional users rather than immediately constructing the entire macro wireless facility. This requirement may be waived by the review authority upon a showing of fact to overcome the presumption that multiple transmitters are desirable on the proposed facility. g. All macro wireless facilities, regardless of the zoning district in which the structure is located, must be located at least one mile, measured in a straight line, from any other macro wireless facility. An exception to this requirement may be granted by the review authority when it is found and factually supported in the written record that the criteria of 6.i below are met and a need exists for the proposed location to avoid service gaps, or that a closer placement is desirable to advance the purpose of this chapter. h. A new macro wireless facility may only be approved when the applicant can demonstrate in writing that no existing or approved micro-scale, small wireless facility or large scale wireless facility within the required separation distance of the proposed site can accommodate the applicant's proposed antenna. i. In addition to the other review criteria of this chapter, affirmative findings for at least one of the following criteria must be made in order for the conditions necessary for approval to exist: (1) No existing or proposed structures located within the geographic search ring are adequate to support the proposed antennas are required to meet the applicant's engineering and service requirements; (2) Existing or approved structures are not of sufficient height to meet the applicant's engineering and service requirements and a combination of smaller scale facilities will not provide for adequate service delivery; (3) Existing or approved structures do not have sufficient structural strength to support the applicant's proposed antenna and related equipment and cannot be reinforced to provide sufficient structural strength; (4) The applicant's proposed antennas would cause electromagnetic interference with the antenna on the existing or approved antenna support structures, or the antenna on the existing or approved antenna support structures would cause interference with the applicant's proposed antenna; (5) Property owners' or owners of existing or approved wireless facilities or locations for smaller scale installations are unwilling to accommodate the applicant's needs; or (6) The applicant demonstrates that there are other factual and verifiable limiting factors that render existing or approved wireless facilities unsuitable. 7. Eligible facility requests. An eligible facility request for collocation on or modification of an existing tower or base station must demonstrate that the proposed installation or modification will not constitute a "substantial change" as that term is defined in 38.800. Projects which are a "substantial change" are reviewed as a new facility. 8. Non-broadcast. A non-broadcast telecommunication facility located within a B-1, B-2, B-2M, B-3 or B-3C district, a mixed-use district, the neighborhood conservation overlay district or a residential zoning district must be enclosed within a structure. The structure must be of materials and architectural character substantially similar to adjacent properties and comply with 38.520.060. The facility must comply with all applicable setbacks. C. Administrative. 1. An inventory of existing sites utilized by the applicant must be provided. The inventory must note the feasibility of accommodating other users. The city may share this information with other applicants or interested parties to encourage collocation. 2. Any antennas or antenna support structures not utilized for the provision of wireless services for a continuous period of six months will be considered abandoned. All facilities must be removed within six months of the cessation of operations. If a facility is not removed within six months the city may remove the facility at the facility or landowner's expense. Where multiple users share a facility, the non-operational antennas and associated ground-mounted equipment may be removed, but any common equipment may be retained until all users have terminated the utilization of the site. 3. Any emergency power supply or other equipment installed at the facility must comply with 38.510.060. 4. No facilities which require employees to be present on a routine basis may be established in residential areas, with the exception of periodic maintenance activities, unless the zone allows offices and appropriate review has been completed. 5. Failure to comply with the terms of this chapter is grounds for facilities to be removed by action of the city at the facility or landowner's expense. 6. Any modifications to existing wireless sites that do not meet the definition of an eligible facility request" must only occur in compliance with the review procedures required in 38.330.030.

(Ord. No. 2025-12, § 4(Exh. A), 12-16-2025; Ord. No. 2026-04, § 4, 7-14-2026)

Ask a question about Bozeman law

Corpus searches the Bozeman sections it holds and shows the ones that match, with their citations. Free, no sign-in.