Sec. 38.510.060. - Location and design of service areas and mechanical equipment.

A. Purpose. 1. To minimize adverse visual, odor, and noise impacts of mechanical equipment, utility cabinets and service areas at ground and roof levels. 2. To provide adequate, durable, well-maintained, and accessible service and equipment areas. 3. To protect residential uses and adjacent properties from impacts due to location and utilization of service areas. B. Location of ground related service areas and mechanical equipment. 1. Service areas (loading docks, trash dumpsters, compactors, recycling areas, electrical panels, and mechanical equipment areas) must be located for convenient service access while avoiding negative visual, auditory, olfactory, or physical impacts on the streetscape environment and adjacent residentially zoned properties. Service areas must be sited for alley access if available. The review authority may require evidence that such elements will not significantly impact neighboring properties or public areas. (For example, the review authority may require noise damping specifications for fans near residential zones.) 2. Exterior loading areas. Exterior loading areas for commercial uses must not be located within 20 feet of a residentially zoned property unless the review authority finds such a restriction does not allow feasible development, and alternative design measures can successfully mitigate potential negative impacts. For example, areas and drives may be required by the review authority to be separated from the residential lot by a masonry wall at least eight feet high. 3. Service areas must not be visible from the sidewalk and adjacent properties. Where the review authority finds that the only option for locating a service area is an area visible from a public right-of-way, internal pathway or pedestrian area, or from an adjacent property, the area may be required to be screened with structural and landscaping screening measures provided in subsection C below and 38.540. Service elements accessible from an alley are exempt from screening requirements. 4. Design for safety. Other provisions of this section notwithstanding, service areas used by residents must be located to avoid entrapment areas and other conditions where personal security is potentially a problem. The review authority may require pedestrian-scaled lighting or other measures to enhance security. 5. Locate and shield noise producing mechanical equipment such as fans, heat pumps, etc., to minimize sounds and reduce impacts to adjacent residentially zoned properties. [image omitted; see the official code] Figure 38.510.060-1. Service element location. C. Screening of ground related service areas and mechanical equipment. 1. Where screening of ground level service areas is required (see subsection B above), the following applies: a. A structural enclosure must be constructed of masonry, heavy-gauge metal, or decayresistant material that is also used with the architecture of the main building. The review authority may allow materials other than those used for the main building if the finishes are similar in color and texture or if the proposed enclosure materials are more durable than those for the main structure. The walls must be sufficient to provide full screening from the affected roadway, pedestrian areas or adjacent use. The enclosure may use overlapping walls to screen dumpsters and other materials (see Figure 38.510.060-2 below); b. Gates must be made of heavy-gauge, site-obscuring material. Chain link or chain link with slats is not an acceptable material for enclosures or gates; c. Where the inside of service enclosures is visible from surrounding streets, pathways, and buildings, an opaque or semi-opaque horizontal cover or screen must be used to mitigate unsightly views. The horizontal screen/cover should be integrated into the enclosure design and compatible with adjacent development; d. Collection points must be located and configured so the enclosure gate swing does not obstruct pedestrian or vehicular traffic. Ensure that screening elements allow for efficient service delivery and removal operations. e. The service area must be paved. D. Departures. Departures to the provisions of subsection B.1, subsection B.2, and subsection B.3 above will be considered per 38.760.060 provided the enclosure and landscaping treatments provide an equivalent degree of screening and add visual interest to site users. [image omitted; see the official code] Figure 38.510.060-2. Acceptable screening enclosures. E. Utility meters, electrical conduit, and other service utility apparatus. These elements must be located and/or designed to minimize their visibility to the public. Project designers are strongly encouraged to coordinate with applicable service providers early in the design process to determine the best approach in meeting these standards. If such elements are mounted in a location visible from the street, pedestrian pathway, shared open space, or shared auto courtyards, they must be screened with vegetation and/or integrated into the building's architecture except for fire protection system devices and equipment (FDC-fire department connection, Horn/Strobe device). Per adopted fire code these must not be obscured and have a sidewalk/landing to public way. [image omitted; see the official code] Figure 38.510.060-3. Utility meter location and screening—Good and bad examples. F. Location and screening of roof and wall mounted mechanical equipment. 1. All rooftop mechanical equipment, including air conditioners, heaters, vents, and similar equipment must be fully screened from public view at grade with the exception of solar panels and roof-mounted wind turbines. Screening must be located so as not to interfere with operation of the equipment. Equipment set back from the roof edge by twice the height of the equipment has met the screening standard without further physical screening. 2. For rooftop equipment, all screening devices must be well integrated into the architectural design through such elements as parapet walls, false roofs, roof wells, clerestories, or equipment rooms. Screening walls or unit-mounted screening is allowed but less desirable. Wood must not be used for screens or enclosures. Louvered designs are acceptable if consistent with building design style. Perforated metal is not permitted. 3. The screening materials must be of material requiring minimal maintenance, and must be as high as the equipment being screened. 4. Locate and shield noise producing mechanical equipment such as fans, heat pumps, etc. to minimize sounds and reduce impacts to adjacent properties. 5. Wall mounted mechanical equipment must not be located adjacent to outdoor amenity spaces used to meet the requirements of this section or 38.260.040. [image omitted; see the official code] Figure 38.510.060-4. Examples of how to screen roof-mounted mechanical equipment.

(Ord. No. 2025-12, § 4(Exh. A), 12-16-2025)

Ask a question about Bozeman law

Corpus searches the Bozeman sections it holds and shows the ones that match, with their citations. Free, no sign-in.