Sec. 38.560.040. - Site lighting.
A. Parking lot lighting. 1. Basic lighting provides for the safety of customers and employees during business hours, and for the security of on-site, outside storage of goods and/or materials. 2. Security lighting provides for the safety of employees during nonbusiness hours, and for the security of on-site, outside storage of goods and/or materials. Table 38.560.040-1 Basic Lighting | Security Lighting Minimum horizontal illuminance in maintained footcandles | 0.2 | 0.5 Minimum vertical illuminance in maintained footcandles | 0.1 | 0.25 Uniformity ratio, maximum: minimum | 20:01 | 15:00 Source: Parking Lot Lighting, Illuminating Engineering Society of North America, 1998. B. Building entrances. Illuminance for building entrances (including commercial, industrial, institutional and municipal) must average 5.0 maintained footcandles. C. Car dealership lighting. Table 38.560.040-2 Area | Maximum Illuminance on Pavement (in Maintained Footcandles) | Uniformity Ratio Maximum: minimum Main business districts Adjacent to roadway | 10—20 | 5:01 Other rows | 5—10 | 10:01 Entrances | 5—10 | 5:01 Drive aisles | 2—3 | 10:01 Secondary business districts Adjacent to roadway | 5—10 | 5:01 Other rows | 2.5—5 | 10:01 Entrances | 2.5—5 | 5:01 Drive aisles | 1—2 | 10:01 Source: Lighting for Exterior Environments, Illuminating Engineering Society of North America, 1998. D. Service station or gas pump area lighting. Table 38.560.040-3 Area Description | Average Illuminance on Described Area (in Maintained Footcandles) Approach with dark surroundings | 1.5 Driveway with dark surroundings | 1.5 Pump island area with dark surroundings | 5 Building façades with dark surroundings | 2 Service areas with dark surroundings | 2 Landscape highlights with dark surroundings | 1 Approach with light surroundings | 2 Driveway with light surroundings | 2 Pump island area with light surroundings | 10 Building façades with light surroundings | 3 Service areas with light surroundings | 3 Landscape highlights with light surroundings | 2 Source: Lighting for Exterior Environments, Illuminating Engineering Society of North America, 1998. E. Site lighting support structures. The ballasts; pole type, strength and anchor bolts; and pole foundation must be appropriate for the proposed lighting and must be installed per the manufacturer's recommendations. Height must be measured from grade. Except as allowed in 38.560.050 and 38.560.070, light poles for parking lot lighting may not exceed 25 feet. F. Site lighting installation and maintenance. 1. For new installations, electrical feeds for fixtures mounted on poles must be run underground, not overhead. 2. Poles supporting lighting fixtures for the illumination of parking areas and located directly behind parking spaces must be placed a minimum of five feet outside the paved area or on concrete pedestals at least 30 inches high above the pavement, or suitably protected by other approved means. 3. Lighting fixtures and ancillary equipment must be maintained so as always to meet the requirements of this section. G. Miscellaneous site lighting specifications. Except as otherwise allowed in this section, all lighting must comply with the following requirements: 1. All outdoor lighting, whether or not required by this section, must be aimed, located, designed, fitted and maintained so as not to present a hazard to drivers or pedestrians by impairing their ability to safely traverse and so as not to create a nuisance by projecting or reflecting objectionable light onto a neighboring use or property. 2. All outdoor lighting fixtures must be shielded in such a manner that no light is emitted above a horizontal plane passing through the lowest point of the light emitting element, so that direct light emitted above the horizontal plane is eliminated. 3. Except for residential lighting, street lighting, pathway intersection lighting and security lighting, all lighting must be turned off between 11:00 p.m. and 6:00 a.m. Exceptions will be granted to those businesses which operate during these hours; such lighting may remain illuminated only while the establishment is actually open for business. 4. Vegetation screens may not serve as the primary means for controlling glare. Rather, glare control must be achieved primarily through the use of such means as cutoff fixtures, shields and baffles, and appropriate application of fixture mounting height, wattage, aiming angle and fixture placement. 5. All outdoor lighting must be designed and located such that the maximum illumination measured in footcandles at the property line may not exceed 0.3 onto adjacent residential properties and 1.0 onto adjacent commercial properties and public rights-of-way. 6. Externally illuminated wall-mounted and pole signs must be lighted by fixtures mounted at the top of the sign and aimed downward; ground-mounted sign lighting may be used only for monument style signs. Fixtures used to illuminate signs must be aimed so as not to project their output beyond the sign. 7. Floodlights, spotlights or any other similar lighting may not be used to illuminate buildings or other site features unless approved as an integral architectural element on the development plan. On-site lighting may be used to accent architectural elements but not to illuminate entire portions of buildings; building illumination may not exceed more than 15 percent of the total wall area of a building. Where accent lighting is used, the maximum illumination on any vertical surface or angular roof surface may not exceed 5.0 average maintained footcandles. Building façade and accent lighting will not be approved unless the light fixtures are carefully selected, located, aimed and shielded so that light is directed only onto the building façade and spillover light is eliminated. Directional fixtures used to illuminate flagpoles (state, United States and/or foreign nations) may project their output beyond the flagpole. 8. Lights that flash, move, revolve, rotate, scintillate, blink, flicker, vary in intensity or color more than once every 24 hours, or use intermittent electrical pulsation are prohibited. 9. Translucent awnings and canopies used for building accents over doors, windows, etc., may not be internally lit (i.e., from underneath or behind). 10. Searchlights, laser source lights or any similar high-intensity light are not permitted, except in emergencies by police and fire personnel or at their direction, for meteorological data gathering purposes, or for special events if a permit is obtained from the review authority.
(Ord. No. 2025-12, § 4(Exh. A), 12-16-2025)
Ask a question about Bozeman law
Corpus searches the Bozeman sections it holds and shows the ones that match, with their citations. Free, no sign-in.