§ 38.800.060 — E definitions
Bozeman Municipal Code, City of Bozeman, Montana (Codified through Order No. 2026-11, adopted September 15, 2026. (Supp. No. 16, Update 1)) · Bozeman Municipal Code § 38.800.060
Corpus is an independent public-information project, not the official City of Bozeman website. Stable reference: corpuslaw.us/code/9d144cfd-76a2-4dab-b0a6-ee72558b6884
Sec. 38.800.060. - E definitions.
Easement. A grant by a property owner to the public, a specific person or persons, other than the owner, for a right to use land for a specific purpose or purposes. Effective base flood elevation. The base flood elevation contained in the effective FEMA flood insurance study and its effective hydraulic model, including any effective FEMA revisions thereto. Effective regulatory floodway. The regulatory floodway contained in the effective FEMA flood insurance study and its effective hydraulic model, including any effective FEMA revisions thereto. Elevated building. A building without a basement that has it lowest elevated floor raised above ground level by foundation walls, shear walls, posts, piers, pilings or columns. A building on a crawlspace is considered an elevated building. Enclosure. For the purposes of 38.600, that portion below the lowest elevated floor of an elevated building that is either partially or fully shut in by rigid walls, including a crawlspace, sub grade crawlspace, stairwell, elevator, or a garage below or attached. Encroachment. For purposes of 38.600 any use, activity, or artificial obstruction within the regulated flood hazard area. Encroachment analysis. A hydrologic and hydraulic analysis performed by a qualified professional engineer to assess the effects of a proposed use, activity, or artificial obstruction on the base flood elevation, flood flows and flood velocities. Engineer (registered professional engineer). A person licensed in conformance with the Montana Professional Engineers Registration Act (MCA 37-67-101 through 37-67-332) to practice engineering in the state. Engineering division. Engineering Division of the City of Bozeman's Department of Transportation and Engineering. Essential services (Type I). Small-scale and below ground facilities, equipment and structures required for the provision of immediate customer service of public and quasi-public services within the city. Additional items may be determined by the community development director to be appropriately included in this definition. These facilities, equipment and structures include: 1. Public water distribution lines. 2. Public sanitary sewer collection lines. 3. Stormwater drainage collection lines, stormwater drainage retention/detention ponds, and drainageways. 4. Fire hydrants. 5. Electric service: a. Below ground distribution and local transmission lines, cables and appurtenances. b. Above ground distribution and local transmission lines, cables and appurtenances no greater in height than the minimum required by the National Electric Safety Code (NESC) plus 15 percent. c. Electric vehicle chargers inside of buildings; or outside of buildings and providing 240 volt or less individual station charging capacity. 6. Natural gas service: a. Below ground distribution lines and appurtenances. b. Below ground transmission lines and appurtenances. c. Natural gas regulator/valve stations and appurtenances, with no above ground buildings. 7. Communications services: a. Below ground telephone lines and cables. b. Below ground cable television lines. c. Below ground electronic data transmission lines and cables. 8. Above ground utility boxes, not to exceed 20 square feet in footprint. 9. Single user building-mounted solar energy facility, and associated storage. 10. Public and amateur radio antennae and towers. Essential services (Type II). Facilities, equipment and structures required for the provision of neighborhood level public and quasi-public services within the city. Additional items may be determined by the community development director to be appropriately included in this definition. Specific facilities, equipment and structures include: 1. Public water storage facilities; and pumping stations. 2. Public sanitary sewer or storm sewer lift stations. 3. Water fill stations for firefighting equipment. 4. Electric service: a. Transmission lines, cables and appurtenances operable prior to September 3, 1991 including the repair and replacement of the same as necessary to maintain their operation. b. Transmission lines, cables, and appurtenances 161 kV or less and no greater in height than the minimum required by the National Electric Safety Code (NESC) plus 25 percent, other than those included in Essential Services (Type I). c. Shared building-mounted solar energy facility, or other on-site generation, building mounted and associated storage. d. Electric vehicle charger outside of a building and providing charging capacity greater than allowed as an Essential Service (Type I). 5. Natural gas service: a. Natural gas regulator/valve stations and appurtenances, with above ground buildings not to exceed 150 square feet. 6. Communications services, except those included in essential services (Type 1), including above ground buildings not to exceed 150 square feet: a. Telephone lines and cables. b. Cable television lines. c. Electronic data transmission lines and cables. 7. Above ground utility boxes, from 20—150 square feet, except those included in essential services (Type I). 8. Shared heating and cooling systems serving multiple buildings. Essential services (Type III). Community-scale facilities, equipment and structures required for the provision of public services not otherwise listed as an essential services (Type I or II). 1. Public water treatment. 2. Sanitary sewer treatment. 3. Storm sewer treatment. 4. Police and fire stations. 5. Battery energy storage systems, electric substations and electrical transmission lines, cables and appurtenances, except those included in essential services (Type I) or essential services (Type II). 6. Natural gas regulator/valve stations and appurtenances, with above ground buildings in excess of 150 square feet. 7. Communications including but not limited to telephone satellite community dial offices; telephone exchanges and repeater stations, except those facilities which may be considered wireless facilities. 8. Gasoline, oil and coal pipelines. 9. Shared ground-mounted solar energy facility, and associated storage. Establish. To construct, place, insert or excavate. Evergreen tree or shrub. A tree or shrub of a species which normally retains its leaves/needles throughout the year. Existing artificial obstruction or nonconforming use. For purposes of 38.600, an artificial obstruction or nonconforming use that lawfully existed prior to the initial creation of city floodplain regulations on March 19, 1975, or any repeal and replacement or amendment thereto. Existing base flood elevation. The base flood elevation computed by hydraulic modeling of the base flood discharge within the floodplain of the flooding source in its current existing condition. Existing building or structure. For purposes of 38.600, any buildings or structures for which the start of construction commenced before the effective date of the applicable flood insurance rate map. Existing manufactured home park or subdivision. A manufactured home park or subdivision where the construction of facilities for servicing the manufactured home lots is completed before the effective date of the floodplain management regulations. This includes, at a minimum, the installation of utilities, the construction of streets, and either final site grading or the pouring of concrete pads. Existing regulatory floodway. The regulatory floodway computed by hydraulic modeling of the base flood discharge within the floodplain of the flooding source in its current existing condition.
(Ord. No. 2025-12, § 4(Exh. A), 12-16-2025)
Ask a question about Bozeman law
Corpus searches the Bozeman sections it holds and shows the ones that match, with their citations. Free, no sign-in.
