Sec. 30-34. - Construction of new chimneys and smokestacks.
The stacks or chimneys when new buildings are being constructed must be of sufficient height in cross section areas to provide the necessary draft for the proper operation of the boiler or heating device, and shall comply with all requirements of the building code. The top of the stack must be of such height in relation to the adjoining buildings that the gas as discharged shall not become a nuisance to adjacent buildings and that downdraft shall be prevented. The stack must be so located in reference to the boiler as to permit a well-designed breaching of adequate size, with a minimum number of bends or turns and with the shortest practicable length. A cleanout door must be provided at the base of the stack, and provisions must be made to permit the unrestricted admission to the boiler room of a sufficient amount of air to secure smokeless combustion of the fuel and to ventilate properly the room in which the fuel-burning equipment is located.
(Code 1987, § 4-69)