§ 62-136 — Billed wastewater discharge versus actual wastewater discharge
Code of Ordinances, City of Concord, North Carolina (Supp. 53 Update 2: codified through Ordinance No. 26-83, enacted August 13, 2026 (online updated September 15, 2026)) · Concord Code of Ordinances § 62-136
Corpus is an independent public-information project, not the official City of Concord website. Stable reference: corpuslaw.us/code/9fd521f5-2595-452a-ae76-bd7da4aaf62a
Sec. 62-136. - Billed wastewater discharge versus actual wastewater discharge.
If industrial customers have data verifying that process water is not discharged into the Concord Utilities System, then the wastewater discharge can be measured by one of the following methods: (1) If the volume of wastewater created by an industrial customer is similar to the volume of water used from the City's water distribution system, then the volume of water purchased from the City shall be considered to be equal to the volume of wastewater discharged to the Concord Wastewater Collection System. (2) If a substantial portion of the water used from the City's water distribution system is not used by the industrial customer's facility or is not discharged to the City's wastewater collection system, the quantity of wastewater discharged to the wastewater collection system shall be determined by one of the following means: a. Flow meter(s) on the water service line(s) to a specific operation(s), or b. Flow meter(s) on the wastewater service line(s) from a specific operation(s), or c. If any industrial customer, now discharging or proposing to discharge wastewater into the City's wastewater collection system does not secure their property's entire water supply from the City's water distribution system, such user shall do the following: 1. Install and maintain a flow meter(s) on the sewer line(s) from all process operations, and 2. Install additional flow meters on the private water supply as required to permit the determination of the total quantity discharged to the City's wastewater collection system from all sources under procedures comparable to paragraphs 1. or 2. in this subsection. (3) If flow meter(s) are installed in full compliance with Concord Utilities' requirements as stipulated in the City's flow meter specifications for wastewater collection systems adopted concurrently with this chapter and incorporated herein by reference as if written below, then the customer shall perform calibrations and certifications pursuant to this chapter and any contract between the City and the customer. (4) All sources of water supplied to the industrial customer and all discharges of wastewater into the City's wastewater collection system shall be identified and metered in accordance with this section. Any wastewater that is not accounted for but discharged to the City's wastewater collection system shall be considered an illegal discharge and shall be subject to all penalties described in section 62-8.
(Ord. No. 04-17, § 1, 3-11-2004)
Ask a question about Concord law
Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.