§ 62-161 — Cross-connection control
Code of Ordinances, City of Concord, North Carolina (Supp. 53 Update 2: codified through Ordinance No. 26-83, enacted August 13, 2026 (online updated September 15, 2026)) · Concord Code of Ordinances § 62-161
Corpus is an independent public-information project, not the official City of Concord website. Stable reference: corpuslaw.us/code/c0b856cc-af1d-42e4-8ff5-75d2c6875488
Sec. 62-161. - Cross-connection control.
(a) Purpose. The purpose of this cross connection control section is: (1) To protect the public potable water supply of the City from the possibility of contamination or pollution, due to backsiphonage or back pressure, by isolation within the consumer's private water system such contaminants or pollutants, which could backflow into the public water system. (2) To define the authority of the City as the water purveyor entitled to eliminating all cross connections, new or existing, within Concord Utilities Water System. (3) To provide a continuing inspection program of cross connections, which may be installed in the future. (b) City's responsibility. (1) Concord Utilities will be primarily responsible for preventing any contamination or pollution of the Concord Utilities Water System. This responsibility begins at the point of origin of the public water supply and includes all of the public water distribution system, and ends at the service connection under the Safe Drinking Water Act. The Backflow Administrator shall exercise vigilance to ensure that the consumer/customer has taken the proper steps to protect the public potable water system. (2) When it has been determined that a backflow protection assembly is required for the prevention of contamination of the Concord Utilities Water System, the Backflow Administrator shall notify the owner, in writing, of any such building or premises, to correct within a time set by this section, any plumbing installed or existing that is in violation of this section. (3) After surveying the private water system the Backflow Administrator will select an approved backflow prevention assembly required for containment control to be installed at service entrance. (4) Prior to the installation of any backflow prevention assembly, the owner of the private water system must be notified that the installation of a backflow prevention assembly may create a closed system, and as a result thermal expansion may occur. Under such circumstance, the customer must understand and assume all liability and responsibilities for that phenomenon. (c) Customer's responsibility. (1) The customer has the responsibility of preventing contaminants and pollutants from entering the customer's private water system or the public water system operated by the City. The customer, at his own expense, shall install, operate and maintain all backflow prevention assemblies specified within this section. (2) If a tenant customer does not maintain the private water system and has no authority to bring the system into compliance with the provisions of this section the City may assert any available action against the tenant to assure the private water system is brought into compliance with this section. (d) Right of entry; authorization. (1) Any authorized representative from the City shall have the right to enter any building, structure, or premises during normal business hours to perform any duty imposed upon him by this section and with in accordance to Appendix D104.2.1 of the State Plumbing Code. Those duties may include sampling and testing of water, or inspection and observation of all piping systems connected to the public water supply. Refusal to allow these representatives to enter for these purposes will result in the disconnection of water service. (2) On request, the consumer shall furnish to the water purveyor any pertinent information regarding the water supply system on such property where cross connection and backflow are deemed possible. (State Plumbing Code Appendix D104.2.3) (e) Unprotected cross connection. (1) No water service connection to any private exterior or interior water system shall be installed or maintained by Concord Utilities unless the water supply is protected as required by this section and other applicable laws. Service of water to any premises shall be discontinued by the City if a backflow assembly, required by this section, is not installed, tested, and maintained or if a backflow assembly has been removed, bypassed, or if an unprotected cross connection exists on the premises. Service will be restored after all such conditions or defects are corrected. (Section 62-154(a)) (2) No customer shall allow an unprotected cross connection to be made or to remain involving the customer's exterior or interior private water system. (3) No connection shall be made to an unapproved auxiliary water supply unless the public water supply is protected against backflow by an approved backflow assembly, appropriate to the degree of hazard. (4) No customer shall fail to maintain in good operating condition any backflow prevention assembly, which is part of the customer's private water system and is required by this section. (5) No customer shall fail to submit to the City any record, which is required by this section. (f) Installation and testing of backflow prevention assembly. (1) The purpose of this subsection is to require that all water flowing from the Concord Utilities Water System must flow through an approved backflow prevention assembly and that each backflow prevention assembly be properly located, installed, maintained and tested so that the backflow prevention assembly is effective in protecting the Concord Utilities Water System from any possible contamination or pollution. (2) The installation or replacement of a backflow prevention assembly for domestic water use shall only be performed by a licensed plumber or utility contractor. The installation of a backflow prevention assembly on a dedicated fire sprinkler service shall be performed by a licensed fire sprinkler contractor or utility contractor. Repairs to a backflow prevention assembly on a dedicated fire sprinkler system may only be performed by a fire sprinkler contractor. All backflow prevention assemblies may be tested by a certified backflow technician authorized by the City. (3) All new construction plans and specifications which will directly effect Concord Utilities, and/or are required by the State Building Code, the State Division of Environmental Health (N.C. DEQ), and City or county planning and zoning offices, shall be made available to the City's Backflow Administrator for review, approval, and to determine the degree of hazard. (4) All existing facilities zoned commercial or industrial and have existing water services with Concord Utilities and requesting certificate of compliance from the City or County Planning and Zoning Offices, shall be inspected for compliance of backflow and cross connection control prevention. Any facility not having backflow protection or changing the degree of hazard shall be brought into compliance before the Backflow Administrator may release certificate of compliance. (5) All backflow prevention assemblies must be installed and maintained on the customer's premises as part of the customer's private water system at or near the service connection and before the service line is connected to any other pipes except as authorized by the water purveyor. (6) If it has been determined that a backflow prevention assembly cannot be installed at the meter service, due to zoning or DOT rights-of-way, an approved backflow assembly must be installed on every branch of plumbing installed between the service meter and the service backflow assembly. (7) Any branch of plumbing installed on the private water system that may be of a greater hazard than the supply line, (example: chemical induced irrigation or fire systems, pump systems, etc.) shall be protected with a reduced pressure assembly. (8) All backflow prevention assemblies shall be installed in accordance with the City's "Backflow Prevention and Cross Connection Control Manual", (which is incorporated herein by reference as if written below), and/or the manufacturer's instructions, whichever is most restrictive. (9) All double check valve assemblies, two-inches or larger, must be installed in a watertight drainable pit wherever belowground installation is necessary in accordance with detailed specifications provided in the Backflow Prevention and Cross Connection Control Manual. If drain cannot be provided, the assembly must be installed above the ground. Double check valve assemblies may be installed in a vertical position with prior approval from the Backflow Administrator, provided that the flow of water is in an upward direction. (10) Reduce pressure assemblies must be installed in a horizontal position and in a location in which no portion of the assembly can become submerged in any substance under any circumstances. Pit installations are prohibited. (11) Each backflow prevention assembly that is required must function properly at time of installment. Each customer will be required to test, maintain, and repair each assembly required which is a part of the customer's private water system. A certified backflow prevention technician may only conduct such test. Testing shall be done immediately following installation of any backflow prevention assembly and on an annual basis except residential irrigation assemblies. Residential irrigation assemblies must be tested immediately after installation and every three years thereafter. (12) If repair is found necessary on an assembly it must be repaired within 30 days and retested. A complete duplicate copy of any testing and/or repair shall be sent to the City within 30 days of completion of test or repair. Each customer must maintain a complete copy of test or repair. Each customer must maintain a complete copy of any test or repair for no less than five years. All test and repair records must be maintained on forms approved by the backflow administrator of the City. (13) All rubber components must be replaced every five years or as often as needed. (14) Any customer installing a reduced pressure (RP) or double check valve assembly (DCVA) must provide the following information to the Backflow Administrator within ten days after installation: a. Service address where assembly is located; b. Owner; c. Description of assembly's location; d. Date of installation; e. Type of assembly; f. Manufacturer; g. Model number; h. Serial number; and i. Test results/reports. (15) The Backflow Administrator must approve each backflow assembly required by this section. Unapproved backflow assembly must be replaced, within a time set by the Backflow Administrator, with an approved backflow assembly. For a list of approved backflow assemblies reference the City's "Backflow Prevention and Cross Connection Control Manual." (16) If it has been determined that a customer must install a backflow prevention assembly, the Backflow Administrator will provide the customer with a letter of notification. The following time periods shall be set forth for the installation of the specified assemblies: Health hazard—60 days. Non-health hazard—90 days. (17) If an imminent hazard or unreasonable threat of contamination or pollution to the Concord Utilities Water System is detected, the Backflow Administrator may require the installation of the required backflow assembly immediately or within a shorter time period than specified in subsection (16) of this subsection. (18) If a customer does not wish for water service to be interrupted when a backflow assembly is tested, repaired, or replaced, a parallel installation must be made using an approved assembly of the same degree of hazard. The parallel line may be of the same size or smaller. (g) Degree of hazards. (1) Determining degree of hazard. a. No service shall be completed until the Backflow Administrator has been provided information or has surveyed the private water system to determine the degree of hazard and make a determination of a backflow prevention assembly to be installed to protect the public water supply. b. Any customer making any modification to their private exterior or interior water system configuration and/or changes the usage of the exterior or interior water system, which may change the degree of hazard, the customer shall notify the Backflow Administrator before any modification is made. If the Backflow Administrator determines that such modification requires a different backflow prevention assembly, that assembly must be installed before the modification is made or the usage is changed. c. The following types of facilities or services have been identified by Concord Utilities as having a potential for backflow or non-potable water into the public water supply system. Therefore, an approved backflow prevention assembly will be required on all such services according to the degree of hazard present. Other types of facilities or services not listed in this subsection may also be required to install approved backflow prevention assemblies if determined necessary by the City's Backflow Administrator. As a minimum requirement, all commercial services will be required to install a double check valve assembly unless otherwise listed as follows: DCVA = Double check valve assembly RP = Reduced pressure assembly DCDA = Double check detector assembly RPDA = Reduced pressure detector assembly AG = Air gap PVB = Pressure vacuum breaker Aircraft and missile plants: RP Automotive service stations, dealerships, etc.: No health hazard: DCVA Health hazard: RP Automotive plants: RP Auxiliary water systems: Approved public/private water supply: DCVA Unapproved public/private water supply: AG Used water and industrial fluids: RP Bakeries: No health hazard: DCVA Health hazard: Hazard Beauty shops/barber shops: No health hazard: DCVA Health hazard: RB Beverage bottling plants: RP Breweries: RP Buildings—Hotels, apartment houses, public and private buildings, or other structures having unprotected cross connections: (Under five stories) No health hazard: DCVA (Under five stories) Health hazard: RP (Over five stories) All: RP Canneries, packing houses, and rendering plants: RP Chemical plants—Manufacturing, processing, compounding or treatment: RP Chemically contaminated water system: RP Commercial car-wash facilities: RP Commercial greenhouses: RP Concrete/asphalt plants: RP Dairies and cold storage plants: RP Dye works: RP Film laboratories: RP Fire systems: No health hazard: DCDA Health hazard (booster pumps, foams, antifreeze solution, etc.): RPDA Hospitals, medical buildings, sanitarium, morgues, mortuaries, autopsy facilities, nursing and convalescent homes, medical clinics, and veterinary hospitals: RP Individual commercial sales establishments (department stores): No health hazards: DCVA Health hazard: RP Industrial facilities: No health hazard: DCVA Health hazard: RP Laundries: No health hazard: DCVA Health hazard (i.e., dry cleaners): RP Lawn irrigation systems: Health hazard: RP Malls or strip malls (frequent tenant change and photo labs, etc.): Health hazard: RP Metal manufacturing, cleaning processing, and fabricating plants: RP Mobile home parks: No health hazard: DCVA Health hazard: RP Oil and gas production, storage or transmission properties: RP Paper and paper products plants: RP Pest control (exterminating and fumigating): RP Plating plants: RP Power plants: RP Public swimming pools: RP Radioactive materials or substances—Plants or facilities handling: RP Restaurants: No health hazard: DCVA Health hazard: RP Restricted, classified, or other closed facilities: RP Rubber plants (natural or synthetic): RP Sand and gravel plants: RP Schools, and colleges: RP Sewage and storm drain facilities: RP Waterfront facilities and industries: RP All assemblies and installations shall be subject to inspection and approval by Concord Utilities. d. Filling of tanks/tankers or any other container from a City-owned fire hydrant is strictly prohibited unless it has been equipped with the proper meter and backflow protection, at which point Concord Utilities will issue a permit for that tank/tanker or container. Any unauthorized connection to a fire hydrant is considered an illegal cross connection to the Concord Utilities water system and will be subject to fines. e. If a cross connection control inspector is unable to survey any portion of a private exterior or interior water system to determine the degree of hazard, due to confidential activities, a reduced pressure assembly will be required. (Section 62-156(a)) (2) Low hazard. a. All single-family residential homes will be considered a low hazard and shall have a minimum of a dual check valve device installed at the meter service. Dual check valves shall not be in-line tested. b. If no other backflow prevention assembly is specified a double check valve assembly must be installed on all private water systems. (3) Imminent hazard. a. If it has been determined that a customer's private water system has an imminent hazard, such customer must install a backflow prevention assembly specified by the Backflow Administrator and this section. This assembly must be installed within 24 hours of notification from the Backflow Administrator. If the customer fails to install the specified assembly within the allowed time limit, water service to the customer's private water system will be terminated and may be subject to specified civil penalties. If the Backflow Administrator is unable to notify the customer in 24 hours of determining an imminent hazard exist, the Backflow Administrator may terminate water service until the specified assembly is installed. These actions may be carried out under the Safe Drinking Water Act (Title XIV, Section 1431) and the State Plumbing Code (Appendix D104.2.6). b. Only a backflow prevention assembly offering a greater degree of protection may be installed in place of a specified assembly required by this section. (h) Notice of contamination or pollution. (1) If the customer's private exterior of interior water system becomes contaminated or polluted the customer shall notify Concord Utilities immediately. (Section 62-157(a)) (2) If a customer has reason to believe that a backflow incident has occurred between the customer's private exterior or interior water system and the Concord Utilities Water System, the customer must notify Concord Utilities immediately in order that appropriate measures may be taken to isolate and remove the contamination or pollution. (Section 62-157(b)) (Code 1987, § 12-97) (i) Violations. (1) Notification. Notification under this section shall be as described in section 62-8. (2) Penalties. The violation of any part of this section may be punished by a civil penalty listed as follows: a. Unprotected cross connection involving a mobile source or private exterior or interior water system, which has an imminent hazard: $1,000.00 per day not to exceed $10,000.00. b. Unprotected cross connection involving a mobile source or private exterior or interior water system, which is of a moderate or high hazard: The amount established in Code of Ordinances sections 1-6 and 62-8. c. Submitting false records or failure to submit records that are required by this section: The amount established in Code of Ordinances sections 1-6 and 62-8. d. Failure to test or maintain backflow prevention assemblies as required: $100.00 per day. (3) Reduction of penalty. a. The Backflow Administrator may reduce or dismiss any civil penalty imposed under this section if the Backflow Administrator has determined that the person charged with the violation has no past history of violation in a timely manner as set by the Backflow Administrator. b. No civil penalty shall be reduced if it has been determined the violation was intentional. c. Any person violating any part of this section must reimburse the City for any expenses in repairing damage to the Concord Utilities Water System caused by any violation and any expenses incurred for investigating a violation.
(Ord. No. 04-17, § 1, 3-11-2004; Ord. No. 05-13, § 9, 3-10-2005; Ord. No. 21-19, § 1, 3-11-2021; Ord. No. 25-41, § 2, 6-12-2025)
Ask a question about Concord law
Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.