For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 70-222 — Pretreatment of wastewater

Code of Ordinances, City of Durham, North Carolina (Supp. No. 37, Update 1: codified through Ordinance No. 16682, adopted June 15, 2026) · Durham City Code § 70-222

Corpus is an independent public-information project, not the official City of Durham website. Stable reference: corpuslaw.us/code/e12e57a6-b3fb-4464-a7e2-635bfef5d58b

Sec. 70-222. - Pretreatment of wastewater.

(a) Pretreatment facilities. Users shall provide wastewater treatment as necessary to comply with this article and wastewater permits issued under section 70-262 and shall achieve compliance with all national categorical pretreatment standards, local limits, and the prohibitions set out in section 70-216 within the time limitations as specified by EPA, the state, or the director, whichever is more stringent. Any facilities necessary for compliance shall be provided, operated, and maintained at the user's expense. Detailed plans showing the pretreatment facilities and operating procedures shall be submitted to the city for review, and shall be approved by the director before construction of the facility. The review of such plans and operating procedures shall in no way relieve the user from the responsibility of modifying the facility as necessary to produce an effluent acceptable to the city under the provisions of this article. Any subsequent changes in the pretreatment facilities or method of operation shall be reported to and be approved by the director prior to the user's initiation of the changes. (b) Additional pretreatment measures. (1) Whenever deemed necessary, the director may require users to restrict their discharge during peak flow periods, designate that certain wastewater be discharged only into specific sewers, relocate and/or consolidate points of discharge, separate sewage wastestreams from industrial wastestreams, and such other conditions as may be necessary to protect the POTW and determine the user's compliance with the requirements of this article. (2) The director may require any person discharging into the POTW to install and maintain, on their property and at their expense, a suitable storage and flow-control facility to ensure equalization of flow. A wastewater discharge permit may be issued solely for flow equalization. (3) Fat, oil, grease and sand removal systems. a. When removal systems are required. Certain users that prepare, process, or serve food shall install a removal system meeting approved standards that removes and collects fat, oil, and grease from wastewater and shall establish acceptable standard operating procedures for grease disposal. Such users include but are not limited to grocery stores, restaurants, bakeries, and companies, schools, and institutions with on-site cafeterias. The director shall promulgate guidelines that implement this section. These guidelines may, among other things, further define and categorize those users covered by this requirement, and distinguish amongst them; specify the types of removal systems the various categories of establishments must install and the specifications of such systems; establish cleaning schedules for various types of removal systems and frequency of removal of the fat, oil, and grease from the establishment. Other users that generate sand, oil and grease such as car washes, and automotive and machine shops shall install sand, oil, and grease removal systems when the director notifies the user of the need for such system or when it is required by the plumbing code. b. Prohibited discharges into a user's fat, oil and grease removal system. The following shall not be discharged into any fat, oil, and grease removal system: 1. Waste that does not contain fat, oil, grease, and that otherwise does not require treatment; 2. Wastewater from dish washing machines or wastewater with temperature exceeding 150°; 3. Ground residue from food waste grinders and garbage disposals; 4. Sanitary waste; 5. Emulsifiers, chemicals, and enzymes. c. Maintenance and cleaning of system; maintenance of records. Users with removal systems shall clean such systems in accordance with the director's guidelines. Such users shall maintain cleaning records showing the date and time of cleaning and person doing the cleaning for a period of three years. d. Collection of fat, oil, and grease; maintenance of records. Users shall contract for the removal of the fat, oil, and grease collected from the removal system. The contract shall be available on site for inspection by the city. The user shall require the contractor to complete a form provided by the city indicating the ultimate disposition of the fat, oil, and grease collected—e.g., the location of the landfill it is being taken to, if it is conveyed to such landfill, or whether the fat, oil, and grease are being reprocessed or rendered. The user shall also require the contractor to indicate on a form, which, if it is not the city's form, shall be acceptable to the city, each collection made from the user. Such form shall be maintained for a period of three years. e. Monitoring of discharge. The director or designee may require that any user monitor and test their discharge for fat, oil, grease, and/or sand in such a manner and with such methods as are specified by the director. All monitoring results shall be shared with the city. In addition, as a condition of discharging to the system, all users may be monitored by the city without prior notice. f. Variances. The director is authorized to vary application and enforcement of this section in cases where pre-existing users cannot site outside removal systems without extreme hardship because of lack of available adjacent land or other similar circumstances. g. Exemptions. Users that existed prior to October 15, 2001, and have an average monthly water consumption of 1,500 cubic feet or less and which do not discharge more than 250 mg/liter of fat, oil, and grease are exempted form these requirements. Users may be required to prove that they qualify for exemption. (4) Users with the potential to discharge flammable substances may be required to install and maintain an approved combustible gas detection meter.

(Ord. No. 13523, 12-17-2007; Ord. No. 14551, 12-16-2013)

Ask a question about Durham law

Corpus searches the Durham sections it holds and shows the ones that match, with their citations. Free, no sign-in.