§ 12-5-3 — STANDARDS
Code of Ordinances, City of Greenville, North Carolina · Greenville Code of Ordinances § 12-5-3
Corpus is an independent public-information project, not the official City of Greenville website. Stable reference: corpuslaw.us/code/c313a449-eb5c-4e17-8961-dfb5d5190e3b
SEC. 12-5-3 STANDARDS.
(A) Standards, instrumentation, personnel, measurement procedures and reporting procedures to be used in the measurement of sound shall be as specified in this section, and in administrative directives issued by the City Manager. (B) Sound level measurement shall be made with a sound level meter using the A-weighting scale, set on “slow” response. (C) Sound level meters shall be at least Type II meeting American National Standard Institute (ANSI) S1.4-1971 requirements. Persons using the sound level meters shall be trained in sound level measurement and the operation of sound level measurement equipment. (D) The City Manager shall issue an administrative directive adopting standards and procedures for sound level measurement and enforcement consistent with this chapter. (Ord. No. 05-108, passed 9-8-2005)