For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3.4.10 — Employment Center (EC)

Code of Ordinances of the City of High Point, North Carolina (Codified through Ordinance No. 8067/25-45, enacted November 17, 2025 (Supp. No. 9)) · High Point Development Ordinance § 3.4.10

Corpus is an independent public-information project, not the official City of High Point website. Stable reference: corpuslaw.us/code/9a8b3026-461d-4ea7-9931-9480307100a0

3.4.10. - Employment Center (EC)

EC EMPLOYMENT CENTER DISTRICT | A. DISTRICT PURPOSE The EC district is established to accommodate office, warehouse, research and development, light industrial, and supporting activities in a well-planned, high quality business park setting. In addition to typical business park uses, the district also allows retail and service uses intended to serve employees working in the immediate vicinity. In addition to an expectation for high quality design, the district includes standards to help ensure compatibility between development and nearby residential uses. Region-serving commercial and intensive forms of industrial development are prohibited as well as outdoor manufacturing, processing, and storage activities. B. DIMENSIONAL STANDARDS STANDARD | REFERENCE # | OUTSIDE CORE CITY AREA | INSIDE CORE CITY AREA SF Attached & Multi-family | All Other Uses | SF Attached & Multi-family | All Other Uses Minimum District Size (acres) | 5 | 2 Maximum Density (units/acre) | 16 | 16 [1] | 17.6 | 17.6 [1] Minimum Lot Area (square feet) | [image omitted; see the official code] | 40,000 [2] | n/a | 40,000 [2] | n/a Minimum Lot Width (feet) [3] | Interior lot | [image omitted; see the official code] | 150 | 150 [4] | 150 Corner lot | [image omitted; see the official code] Minimum Street Setback (feet) | [image omitted; see the official code] | 15 | 15 [4] Minimum Perimeter Setback (feet) | Adjacent to Residential District | [image omitted; see the official code] | 40 | 25 Adjacent to Nonresidential District | [image omitted; see the official code] | 20 | 10 Max. Building Height (feet) | [image omitted; see the official code] | n/a [5] | n/a [6] [1] Mixed-use development is subject to the maximum density standards. [2] Minimum development size. [3] All development shall comply with the City's Driveway Ordinance requirements. [4] At applicant's option, may be reduced to the lesser of: zoning district minimum or between 75% and 125% of the average of the lots on the same block face (See Section 10.2.3 D, Dimensional Standards in the Core City). [5] For each additional foot of height beyond 50 feet up to 80 feet, the perimeter setbacks shall be increased by 1 foot. [6] When a perimeter setback abuts a single-family residential district, the setback shall be increased by 1 foot for each foot in height beyond 50 feet up to 80 feet. C. TYPICAL BUILDING FORMS [image omitted; see the official code] | [image omitted; see the official code] D. TYPICAL LOT PATTERNS | E. DISTRICT DIMENSIONS [image omitted; see the official code] | [image omitted; see the official code] F. TYPICAL BUILDING CONFIGURATION [image omitted; see the official code] G. District Standards 1. Site Standards The following standards are applied to nonresidential development sites: (a) Building Orientation Single-building developments shall be oriented so that the front facade faces the street from which the building derives its street address. (b) Drive-Throughs Drive-through lanes and windows are prohibited. (c) Fences Non-coated chain link fencing shall not be located between the primary facade of a building and the street it faces, and comply with the standards in Section 5.11, Fences. (d) Ground-based Mechanical Equipment Screening Ground-based mechanical equipment shall be located to the side or rear of the building and comply with the standards in Section 5.6, Screening. (e) Off-Street Loading (1) Loading docks and bays shall be located towards the rear of buildings, or located internally within multi-building developments, and shall not face or be adjacent to public streets. (2) If located on the side of a building it shall be screened in accordance with Section 5.6, Screening. (f) Pedestrian Connections Pedestrian connections with a minimum unobstructed width of 4 feet shall be incorporated to connect a building's primary entrance with all of the following: (1) Off-street parking areas of 30 or more spaces located on the same lot; (2) The principal entrances of all other principal buildings in a multi-building development; (3) The public sidewalk, if one abuts the development; (4) On-site pedestrian amenities; (5) Greenways, trails, or paths located on-site or abutting the development; and (6) Existing or planned transit stops located on-site or abutting the development. (g) Accessory Buildings Accessory buildings shall be located to the side or rear of the development they serve, and shall use the same materials and architectural styling as the principal building they serve. (h) Outdoor Storage Outdoor storage shall: (1) Not cover an area greater than 50 percent of the gross ground floor area of the principal building; (2) Be located between the rear building line of the principal building and the rear lot line; (3) Not be located in any required landscape yard; and (4) Be screened from view from adjacent lots and public streets with an opaque fence, wall, or by any other allowed method in Section 5.6.6, Screening Methods, to a height 6 feet above grade level, provided the screen shall not be allowed in any required landscape yard. (i) Outdoor Manufacturing, Processing, Repair, or Assembly Outdoor manufacturing, processing, repair, or assembly is prohibited and must take place within an enclosed building. 2. Building Standards The following standards are applied to all multi-family residential and nonresidential buildings, except for locally or nationally designated individual historic structures and contributing structures within a locally or nationally designated historic district, provided such structures comply with the Secretary of Interior's Standards for Rehabilitation or are issued a Certificate of Appropriateness, as applicable. (a) Articulation (1) Building facades facing a public street shall include at least 2 or more of the following features: (i) Windows or fenestration; (ii) Changes in wall plane (such as projections or recesses) with an offset or depth of at least 1 foot; (iii) Roofline changes, coupled with correspondingly aligned wall offset or facade material changes, changes in the roof planes, or changes in the height of a parapet wall; (iv) Use of columns, pilasters, piers, architectural boxing, or other technique to break the facade into different volumes; (v) Inclusion of eaves or overhangs; or (vi) Inclusion of an entryway with a roof form that differs from the rest of the facade. (b) Facade Materials (1) Exterior building materials should be continued to the finished grade on any elevation. (2) Building facades utilizing smooth-faced concrete block, or unfinished or untreated tilt-up concrete panels, shall be limited to building facades not visible from public streets as seen from the public right-of-way at a height of 6 feet. (3) The use of vinyl siding or corrugated metal siding and other vertical metal siding is prohibited. (4) The use of high intensity (bright), metallic, or fluorescent colors shall be limited to facade trim or accents and total less than 20% of the area of any building facade. (5) Primary facade materials should not change at outside corners, and should continue around the corner to a logical point of conclusion such as a window or change in facade plane. (c) Roof-Mounted Equipment (1) Flat roofs shall incorporate parapet walls designed to screen the roof and roof-mounted equipment from view from the primary street fronting the building and any abutting side streets as seen from the public right-of-way at a height of 6 feet. The parapet wall should be finished in the same or similar material and color as the building. (2) For sloped roofs, equipment and other roof penetrations should be located and screened to have a minimal visual impact as seen from the public right-of-way at a height of 6 feet. (3) In cases where complete screening is not practicable, all roof- mounted equipment and other roof penetrations shall be camouflaged through the use of paint or architectural techniques to minimize its appearance. (4) Green roofs, which use vegetation to improve stormwater quality and reduce runoff, are exempt from the screening requirements described in this subsection. 3. Retail Sales and Personal Service Uses Retail Sales and Personal Service uses established as a principal use shall be located within a multi-tenant building.

(Ord. No. 7266/17-08, § 7, 1-17-2017; Ord. No. 7365/17-108, § 4.C, 11-20-2017; Ord. No. 7415/18-44, § 2.A, 5-21-2018; Ord. No. 7476/18-105, § 10.C, 12-3-2018)

Ask a question about High Point law

Corpus searches the High Point sections it holds and shows the ones that match, with their citations. Free, no sign-in.