For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3.8.7 — Gateway Corridor Overlay (GCO)

Code of Ordinances of the City of High Point, North Carolina (Codified through Ordinance No. 8067/25-45, enacted November 17, 2025 (Supp. No. 9)) · High Point Development Ordinance § 3.8.7

Corpus is an independent public-information project, not the official City of High Point website. Stable reference: corpuslaw.us/code/a1c76d22-7264-420b-95af-b7feef659b64

3.8.7. - Gateway Corridor Overlay (GCO)

A. Purpose The Gateway Corridor Overlay (GCO) district regulations are intended to enhance the visual appeal of certain thoroughfares in the City, and to: 1. Preserve and enhance the appearance and operational characteristics of certain designated roadways that serve as gateways to the City; and 2. Address development issues of special concern along these gateways, with specific requirements which relate to use, development form, traffic movement, access, environment, landscaping, visual quality, image, and aesthetics. B. Procedure for Establishment of Gateway Corridor Overlay (GCO) Districts Prior to establishment of a GCO district for a specific gateway corridor, a gateway corridor plan for the specific gateway shall be adopted by the City Council. The gateway corridor plan shall describe the conditions, boundaries, development goals, and standards for the proposed GCO district. The plan shall, at a minimum, address the following: 1. The arrangement of uses along the corridor which shall create a visually pleasing impression. 2. The unique qualities of the corridor, such as significant buildings, views and vistas, and natural features which lend themselves to special consideration. 3. The value of the corridor as an entryway to the City which can influence the perception of citizens and persons or businesses considering investment in the City. 4. Transportation conditions on the corridor, including vehicular access, dedication of right-of-way, driveway limitations, and traffic impact. 5. The vision and general goals for development along the corridor, and specific recommendations for regulatory changes to achieve the vision and development goals. C. Gateway Corridor Plan Approval The gateway corridor plan shall be forwarded to the P&Z for its review and recommendations. Upon completion of its review, the plan along with the recommendations of the P&Z shall be forwarded to the City Council for review. A gateway corridor plan shall be approved by the City Council for a specific gateway corridor before establishment of a GCO district for the specific corridor. D. Establishment The specific GCO district shall be established in accordance with Section 2.4.20, Zoning Map Amendment, and Section 2.4.15, Text Amendment (as appropriate), and included as a district in this section. E. General Standards GCO district standards for a specific gateway corridor shall follow the policy direction in the gateway corridor plan approved by the City Council. The GCO district shall, at a minimum, address the following elements: 1. The name and boundaries of the overlay district. 2. The development along the corridor to which the overlay district applies (typically all new development and certain expansions and remodels). 3. Any variations from the requirements of the underlying general zoning district(s). 4. The uses allowed in the district, if appropriate. 5. The development and form standards of the overlay district, including some or all of the following: (a) Dimensions (height, setbacks, build-to-lines, etc.); (b) Streetscape landscaping; (c) Sidewalks and pedestrian circulation features; (d) Off-street parking; (e) Landscaping and tree preservation/reforestation; (f) Open space set-asides; (g) Signage; (h) Exterior lighting; (i) Building design and form; and (j) Road access and traffic circulation. 6. The extent to which a general or district-specific standard may be modified. F. Eastchester GCO District Standards The Eastchester GCO district is hereby established, and shall be subject to the following standards: 1. Boundaries of the District The boundaries of the Eastchester GCO district are shown on the Official Zoning Map. 2. Applicability (a) Application The Eastchester GCO district regulations shall apply to all principal and accessory buildings, off-street parking and vehicular storage areas on lots, or open uses of land constructed, reconstructed, or established after November 5, 1986, or the effective date of the district upon the land, or otherwise provided in Section 3.8.7 F.2(b), Exemptions. (b) Exemptions The following development is exempt from the requirements of the Eastchester GCO district regulations: (1) A single-family detached dwelling or a duplex dwelling on its own lot. (2) Lots with an existing structure subject to a building permit application for improvement, repair, or renovation, provided the proposed changes do not result in a change in the type of occupancy under the State Building Code. (3) Existing development or development that has a vested right under North Carolina law as of November 5, 1986 or the effective date of the district upon the land. 3. Minimum Building Setbacks Lots within the Eastchester GCO shall be subject to minimum building setbacks from Eastchester Drive in accordance with the standards in Table 3.8.7.F.3, Minimum Building Setbacks. The minimum building setback may be reduced to the average streetyard width, in accordance with Table 3.8.7.F.5, Eastchester GCO Landscaping Standards, when off-street parking areas are not located between the front building line and Eastchester Drive and the building facades facing a public street include windows or fenestration, and the inclusion of an entryway with a roof form that differs from the rest of the facade. Ground-based mechanical equipment shall not be placed between the front building line and Eastchester Drive. TABLE 3.8.7.F.3, MINIMUM BUILDING SETBACKS STREET SEGMENT OF EASTCHESTER DRIVE | MINIMUM BUILDING SETBACK FROM ROW EDGE (FEET) North Main Street North to Johnson Street | 50 Johnson Street North to Penny Road | 50 Penny Road North to Gallimore Dairy Road | 75 4. Site Standards (a) Drive-Throughs (1) Outdoor speakers associated with a drive-through shall be located at least 50 feet from a residential district. (2) Drive-through windows, menu boards, drive aisles, and speakers shall not be located between the principal building line and the front street right-of-way. For corner lots, drive aisles shall not be located between the principal building line and the front street right-of-way, to the maximum extent practicable. (b) Fuel Pumps and Canopies Fuel pumps and canopies shall be located behind the rear building line of the principal building, to the maximum extent practicable. (c) Ground-based Mechanical Equipment Screening Ground-based mechanical equipment should be located to the rear of the principal building(s), and shall be screened in accordance with Section 5.6, Screening. (d) Off-Street Loading Off-street loading areas shall be located to the side or rear of the principal building and shall not face Eastchester Drive. 5. Landscaping Requirements Landscaping in the Eastchester GCO shall be in accordance with the provisions of Section 5.5, Landscaping, Table 3.8.7.F.5, Eastchester GCO Landscaping Standards, and the following requirements. In the case of conflict, the stricter standard shall apply. (a) Retention of existing trees to meet planting requirements within landscape yards is strongly encouraged. Existing trees may be credited towards landscaping requirements in accordance with Section 5.5.8, Credit for Existing Vegetation. (b) Stormwater detention ponds shall be screened with landscaping so as to obscure, to the maximum extent practicable, the view from public right-of-way. TABLE 3.8.7.F.5: EASTCHESTER GCO LANDSCAPING STANDARDS REQUIREMENT | NORTH MAIN ST. TO JOHNSON ST. | JOHNSON ST. NORTH TO PENNY RD. | PENNY RD NORTH TO GALLIMORE DAIRY RD. Minimum streetyard width (feet) | 10 | 20 Average streetyard width (feet) [1] | 20 | 40 Maximum streetyard width (feet) | 35 | 50 Minimum number of canopy trees required per 100 linear feet of streetyard | 4 Minimum number of shrubs required per 100 linear feet of streetyard | 17 | 25 NOTES: [1] At least 50 percent of required plantings shall be located within the average streetyard width. 6. Signs Signs shall be in accordance with Section 5.7 Signs. 7. Building Standards The following standards are applied to all multi-family residential and nonresidential buildings, except for locally or nationally designated individual historic structures and contributing structures within a locally or nationally designated historic district, provided such structures comply with the Secretary of Interior's Standards for Rehabilitation or are issued a Certificate of Appropriateness, as applicable. (a) Facade Materials (1) Exterior building materials should be continued to the finished grade on any elevation. (2) Building facades utilizing smooth-faced concrete block, or unfinished or untreated tilt-up concrete panels, shall be limited to building facades not visible from public streets as seen from the public right-of-way at a height of 6 feet. (3) The use of vinyl siding or corrugated metal siding and other vertical metal siding is prohibited. (4) The use of high intensity (bright), metallic, or fluorescent colors shall be limited to facade trim or accents and total less than 20% of the area of any building facade. (5) The use of lighting by direct illumination to outline or accentuate all or part of a structure, building or architectural features of a building, including but not limited to rooflines, windows, doors, cupolas, exterior walls, porches, canopies and awnings, with narrow band, strip, tube or other methods of lighting, is prohibited. (6) Primary facade materials should not change at outside corners, and should continue around the corner to a logical point of conclusion such as a window or change in facade plane. (b) Roof-Mounted Equipment (1) Flat roofs shall incorporate parapet walls designed to screen the roof and roof-mounted equipment from view from the primary street fronting the building and any abutting side streets as seen from the public right-of-way at a height of 6 feet. The parapet wall should be finished in the same or similar material and color as the building. (2) For sloped roofs, equipment and other roof penetrations should be located and screened to have a minimal visual impact as seen from the public right-of-way at a height of 6 feet. (3) In cases where complete screening is not practicable, all roof- mounted equipment and other roof penetrations shall be camouflaged through the use of paint or architectural techniques to minimize its appearance. (4) Green roofs, which use vegetation to improve stormwater quality and reduce runoff, are exempt from the screening requirements described in this subsection. (c) Service or Vehicular Bays Service or vehicular bays and their doors shall not face Eastchester Drive, to the maximum extent practicable. (d) Statement of Design Guidelines (1) General Design guidelines for multi-tenant commercial developments and/or nonresidential group developments shall be required for the purpose of facilitating unified developments with compatible architecture, scale, proportion and building elements that provide visual unity and are harmonious with other buildings in the surrounding area. Prior to the development of any phase of a commercial multi-tenant and/or non-residential group development, design guidelines governing the appearance of all buildings within the property shall be submitted by the developer for the review and approval of the Planning and Development Director prior to the approval of any site plan, group development, or final subdivision plat. The guidelines shall address and include the following criteria: (i) Common sign standards, such as, type, illumination, materials, and color schemes. (ii) Exterior building materials and colors, including examples of materials and colors to be consistent throughout the development. (iii) Roof shape and materials, including examples of materials and colors to be consistent throughout the development. (iv) Facade design, mass, and rhythm. (v) Common landscaping scheme, including street yard, and peripheral plantings, parking area plantings, and tree preservation. (2) Amendment (i) A statement of design guidelines may be amended by an applicant provided the proposed amendments are in keeping with the character, scale, materials, and configuration of the established development or approved statement. (ii) In no instance shall an amendment be requested after 75 percent or more of the total development has been constructed. 8. Character of Development Located at Entrances to Existing Residential Subdivisions (a) Exterior modifications, alterations, additions, or construction of a new multi-family or nonresidential structure on land located at an entrance to a residential subdivision shall retain a residential character, nature and appearance, and be consistent with the following: (1) A maximum of 2 stories in height. (2) A roofline compatible with adjacent residences. (3) Building materials compatible with adjacent residences. (4) Parking areas that are located in a manner which minimizes the impact on adjacent residential dwellings. (5) Window treatments that are compatible with adjacent residences. (6) Landscaping around the foundation of principal buildings. (7) Style, size, and location of exterior lighting. (8) Location, size, color, materials, height, and illumination of signage. (b) The developer shall submit written and/or illustrative information that addresses the above criteria for the review and approval of the Planning and Development Director, either as part of a Statement of Design Guidelines, if design guidelines are required for the proposed development per Section 3.8.7 F.7(d), or as a separate document if design guidelines are not otherwise required. Approval is required prior to the approval of a site plan, group development or final plat, or the issuance of any permit.

(Ord. No. 7266/17-08, § 9, 1-17-2017; Ord. No. 7415/18-44, § 2.B, 5-21-2018; Ord. No. 7488/19-05, § 1, 2-4-2019; Ord. No. 7521/19-38, § 5, 4-15-2019; Ord. No. 7622/20-38, § 14, 8-5-2020; Ord. No. 7750/21-67, § 18, 11-1-2021; Ord. No. 7912/23-27, § 4.C, 4-17-2023)

Ask a question about High Point law

Corpus searches the High Point sections it holds and shows the ones that match, with their citations. Free, no sign-in.