§ 5.10.6 — General Standards for On-Site Exterior Lighting

Code of Ordinances of the City of High Point, North Carolina (Codified through Ordinance No. 8067/25-45, enacted November 17, 2025 (Supp. No. 9)) · High Point Development Ordinance § 5.10.6

Corpus is an independent public-information project, not the official City of High Point website. Stable reference: corpuslaw.us/code/3a4ec220-81ef-4acd-82d8-54c1853a7a85

5.10.6. - General Standards for On-Site Exterior Lighting

A. Maximum Illumination Value at Lot Line Exterior lighting shall be designed and located such that the maximum illumination measured in footcandles at ground level at any lot line shall not exceed the standards in Table 5.10.6.A, Maximum Illumination Levels. TABLE 5.10.6.A: MAXIMUM ILLUMINATION LEVELS ABUTTING USE [1] | MAXIMUM ILLUMINATION VALUE AT LOT LINE (FOOTCANDLES) Residential use or undeveloped land zoned for residential development | 1.0 Institutional use | 1.5 Commercial use or undeveloped land zoned for uses other than residential[2] | 2.5 Vehicular use area | 2.5 NOTES: [1] See Table 4.1.9, Principal Use Table [2] Includes mixed-use development B. Maximum Height The height of exterior lighting, whether mounted on poles, walls, or by other means, shall be no greater than 35 feet above grade at the base of the fixture, except for the following: 1. Lighting for outdoor public recreation, outdoor assembly and similar uses; and 2. Where a larger pole is required to accommodate multiple light fixtures, cameras or similar equipment, or to meet wind load requirements for attached banners, the maximum height may be increased up to 45 feet. C. Light Trespass 1. All outdoor light fixtures that produce more than 4,050 lumens shall be cut-off fixtures that are located, angled, or shielded to focus light on the intended subject or area and prevent light trespass onto adjacent properties or skyward as depicted in Figure 5.10.6.C, Cut-Off Light Fixtures. The lumen output of a lighting fixture is specified by the manufacturer. 2. Exterior lighting devices that produce 4,050 lumens (and need not be cut-off, angled, or shielded) include, but are not limited, to: (a) 200 watt standard incandescent; (b) 150 watt tungsten-halogen (quartz); (c) 50 watt high pressure sodium; (d) 50 watt cool white fluorescent; and (e) 30 watt low pressure sodium. FIGURE 5.10.6.C, CUT-OFF LIGHT FIXTURES [image omitted; see the official code] 3. Wall packs shall be cut-off and floodlights shall be shielded (e.g., true cut-off type bulb or light source not visible from off-site) to direct light downward and eliminate light pollution above the facade of a structure.

(Ord. No. 7365/17-108, § 1, 11-20-2017; Ord. No. 7542/19-59, §§ 4.C, 5, 7-15-2019)

Ask a question about High Point law

Corpus searches the High Point sections it holds and shows the ones that match, with their citations. Free, no sign-in.