For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.14.4 — Large Retail

Code of Ordinances of the City of High Point, North Carolina (Codified through Ordinance No. 8067/25-45, enacted November 17, 2025 (Supp. No. 9)) · High Point Development Ordinance § 5.14.4

Corpus is an independent public-information project, not the official City of High Point website. Stable reference: corpuslaw.us/code/2a69df80-e65b-4e57-840f-6d91746dcb2b

5.14.4. - Large Retail

A. Applicability These standards shall apply outside the Core City to all new commercial uses in the Commercial Use classification in Table 4.1.9, Principal Use Table that have: 1. A gross ground floor area of more than 50,000 square feet for a single tenant; or 2. A gross ground floor area of more than 150,000 square feet serving multiple tenants, including outparcels. B. Development Standards Development subject to the requirements of this section shall comply with the following standards: 1. General (a) Facades that face a street, parking lots on the interior of the site, or other areas that are interior to the site shall have articulation along at least 60 percent of the ground floor facade, in accordance with Section 5.14.4 B.3(a), Facade Articulation. This requirement includes the facade of the building that functions as the rear, yet faces a street (see Figure 5.14.4.B, Facade Facing a Street). FIGURE 5.14.4.B, FACADE FACING A STREET [image omitted; see the official code] (b) The building facade containing the primary entrance shall be considered the primary facade. (c) Minimum street setbacks may be reduced to 10 feet if the development meets all required and recommended standards of this section. (d) Within developments with multiple buildings, building heights shall be varied to avoid the appearance of an elongated building mass. This can be achieved by stair-stepping building heights or by varying roof forms. 2. Site Standards (a) Compliance with Multiple Lot Development Standards Large retail development configured as a multiple building development shall comply with the standards in Section 5.14.5, Multiple Lot Development, in addition to the standards for a large retail development type. (b) Building Location and Orientation (1) Street Corner Location Buildings placed at a street corner should be designed to address both street frontages in an "L" configuration. (2) Multi-building Development (i) Buildings should be located and configured so as to enclose parking areas. (ii) Buildings should include a consistent level of architectural styling and facade articulation on facades facing streets, internal drives, parking lots, or pedestrian amenities. (c) Pedestrian Areas A portion of the spaces between or along the frontages of the buildings should include pedestrian areas such as small plazas, patios, or central gathering spaces with pedestrian amenities. The pedestrian amenities include but are not limited to: seating, outdoor play areas, bicycle racks, kiosks, water features, public art, freestanding structures such as a clock tower, or similar amenities. (d) Loading Docks and Bays Loading docks and bays shall: (1) Be located towards the rear of buildings, or located internally within multi-building developments; (2) Not face or be adjacent to streets, to the maximum extent practicable; and (3) Meet the minimum requirements of Section 5.6, Screening. (e) Accessory Buildings Accessory buildings shall comply with the standards in Section 4.4, Accessory Structures and Uses, and use the same materials and architectural styling as the principal building they serve. 3. Building Standards (a) Facade Articulation Walls requiring articulation must use 2 or more of the following features: (1) Recessed entryways; (2) Display windows; (3) Window indentations (such as but not limited to double-hung, stationary, or casement windows) that are regularly spaced and that incorporate a differing building material, texture, color, awnings, window hoods, or canopies. This shall not include a glass curtain wall or flush mounted glass; (4) Offset surfaces, niches, insets, projections, or bas-relief with a minimum depth of 4 inches; (5) Columns, pilasters, piers, architectural boxing, or other technique to break the facade into different volumes; (6) Textured materials (such as but not limited to brick or stone); (7) Roofline changes, coupled with correspondingly aligned wall offset or facade material changes, changes in the roof planes, or changes in the height of a parapet wall; or (8) Changes in wall plane (such as projections or recesses) with an offset or depth of at least 1 foot and a width of at least 10 feet, located a minimum of every 30 feet. (b) Facade Materials (1) Where 2 or more materials are proposed to be combined on a facade, the heavier and more massive elements should be located below the lighter elements (e.g., brick shall be located below stucco). Heavier materials may also be placed as a detail on the corner of a building or along cornices or windows. (2) Primary facade materials should not change at outside corners, and should continue around the corner to a logical point of conclusion such as a window or change in facade plane. (3) Exterior building materials shall be continued to the finished grade on any elevation. (4) Building facades utilizing smooth-faced concrete block, or unfinished or untreated tilt-up concrete panels, shall be limited to building facades not visible from public streets as seen from the public right-of-way at a height of 6 feet. (5) The use of vinyl siding or corrugated and other vertical metal siding as the sole or primary facade material is prohibited. (c) Facade Transparency When provided, ground floor windows shall maintain non-reflective, transparent glass between 3 feet and 8 feet of the floor. (d) Primary Entrances The primary entrance shall be clearly defined and incorporate the following features: (1) Multi-Tenant Buildings (i) Overhangs, awnings, canopies, or other projections of at least 8 feet, from the building wall; (ii) Windows within or beside entry doors that allow entrants to see into the building. (2) Single Tenant Buildings Distinctive roof forms, towers, gables, roof ridges, peaks, or other features that differ in height by 3 feet or more from the balance of the roof. Outparcels are exempt from this standard. (e) Roof-Mounted Equipment (1) Flat roofs shall incorporate parapet walls designed to screen the roof and roof-mounted equipment from view from the primary street fronting the building and any abutting side street as seen from the public right-of-way at a height of 6 feet. The parapet wall should be finished in the same or similar material and color as the building. (2) For sloped roofs, roof-mounted equipment and other roof penetrations should be located and screened to have a minimal visual impact as seen from the public right-of-way at a height of 6 feet. (3) In cases where complete screening is not practicable, all roof- mounted equipment and other roof penetrations shall be camouflaged through the use of paint or architectural techniques to minimize its appearance. (4) Green roofs, which use vegetation to improve stormwater quality and reduce runoff, are exempt from the screening requirements described in this subsection.

(Ord. No. 7365/17-108, § 1, 11-20-2017; Ord. No. 7415/18-44, § 2.D, 5-21-2018; Ord. No. 7476/18-105, § 10.E, 12-3-2018; Ord. No. 7542/19-59, § 1.I, 7-15-2019)

Ask a question about High Point law

Corpus searches the High Point sections it holds and shows the ones that match, with their citations. Free, no sign-in.