For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.7.9 — Attached Signs Requiring a Sign Permit

Code of Ordinances of the City of High Point, North Carolina (Codified through Ordinance No. 8067/25-45, enacted November 17, 2025 (Supp. No. 9)) · High Point Development Ordinance § 5.7.9

Corpus is an independent public-information project, not the official City of High Point website. Stable reference: corpuslaw.us/code/1564da6e-4184-4ff6-8fb8-2ceec3101c12

5.7.9. - Attached Signs Requiring a Sign Permit

A. Attached Signs Generally 1. Attached signs requiring a sign permit in accordance with Section 2.5.13, Sign Permit, shall comply with the standards of Section 5.7.9, Attached Signs Requiring a Sign Permit. Attached signs within the Institutional District shall comply with Section 5.7.11, Signs in Institutional Districts. (See Section 5.7.16, Sign Images by Sign Type, for visual illustration of attached signs) 2. A summary of the applicable tables and specific provisions regulating attached signs requiring a permit, in addition to illumination provisions, is provided below. a) Table 5.7.9.C: Attached Signs - Maximum Permitted Sign Area Per Principal Building Facade establishes within each zoning district the maximum square feet of sign area permitted on a principal building's facade based on the linear feet of the building's facade (width of the building). b) Table 5.7.9.D: Attached Signs - Maximum Permitted Sign Area by Sign Type establishes the number of permitted signs and size limits by each sign type listed in the table; however, the maximum sign area permitted on the building facade is regulated by Table 5.7.9.C: Attached Signs - Maximum Permitted Sign Area Per Principal Building Facade. c) Table 5.7.9.E: Attached Specialty Signs - Maximum Permitted Sign Area by Sign Type establishes sign standards for attached specialty signs. Attached specialty signs do not count towards the maximum sign allowances in Table 5.7.9.C: Attached Signs - Maximum Permitted Sign Area Per Principal Building Facade and Table 5.7.9.D: Attached Signs - Maximum Permitted Sign Area by Sign Type. Attached Specialty Signs are allowed in addition to other allowable attached signs. d) Subsection 5.7.9.F, Attached Signs on Multi-Tenant Buildings, establishes how standards for signs on multi-tenant buildings are applied on shared building facades. e) Subsection 5.7.9.G, Specific Standards for Attached Signs, establishes additional standards for specific sign types as noted within the tables in Section 5.7.9, Attached Signs Requiring a Sign Permit. B. Illumination Standards for Attached Signs 1. Illuminated attached signs are prohibited in residential districts. 2. In all other districts, signs may be internally or externally illuminated, except that in the AGR, TO, OI, EC, PNR and GCO districts, internal illumination is limited to cut-out letter/graphic or silhouette lighted signs. 3. Specific illumination standards are also provided by sign type in Subsection 5.7.9.G, Specific Standards for Attached Signs. 4. All signs must also comply with the illumination requirements in Section 5.7.6, Illumination Standards. C. Attached Signs - Maximum Permitted Sign Area Per Principal Building Facade. The maximum sign area permitted per principal building facade shall comply with the provisions in Table 5.7.9.C: Attached Signs - Maximum Permitted Sign Area Per Principal Building Facade. TABLE 5.7.9.C: ATTACHED SIGNS - MAXIMUM PERMITTED SIGN AREA PER PRINCIPAL BUILDING FACADE DISTRICT | AREA MULTIPLIER PER LINEAR FOOT OF PRINCIPAL BUILDING FACADE | MAXIMUM SIGN AREA FOR ATTACHED SIGNS ON PRINCIPAL BUILDING FACADE [1] (SF) All Residential Districts - Nonresidential uses only | 0.5 | 50 AGR, TO, PNR | 1 | 50 OI, LB, EC, LI, HI, MS, MX, SMO | 1 | 100 CB | 2 | 300 GB, RC | 2 | 400 GCO | n/a [2] | 200 [3] NOTES: [1] Applies to the maximum square footage for all signs on the principal building facade only; all other facades may have 50% of the allowable square footage of the principal building facade. [2] The GCO is an overlay district and therefore the base district determines the square foot multiplier. [3] The maximum sign area for signs within the GCO is limited to 200 sf or the lesser sign area of the underlying zoning district. D. Attached Signs - Maximum Permitted Sign Area by Sign Type. The permitted number and area by sign type shall comply with the provisions in Table 5.7.9.D: Attached Signs - Maximum Permitted Sign Area by Sign Type. TABLE 5.7.9.D: ATTACHED SIGNS - MAXIMUM PERMITTED SIGN AREA BY SIGN TYPE SIGN TYPE/DISTRICTS | NUMBER | MAXIMUM AREA PER SIGN TYPE [1] (SF) | ADDITIONAL STANDARDS WALL SIGN All Residential Districts - Nonresidential uses only | 1 | 50 AGR, TO, OI, LB, EC, LI, HI, MS, MX, PNR, SMO | n/a | 50 CB | n/a | 200 GB, RC | n/a | 300 GCO | n/a | 100 [2] AWNING SIGN All Nonresidential Districts | n/a | 25% of Awning | 5.7.9.G.1 BUILDING BANNER SIGN MS, MX, SMO | n/a | 16 | 5.7.9.G.3 CB, RC | 20 BUILDING CANOPY SIGN All Nonresidential Districts | 1/canopy face | See Additional Standards | 5.7.9.G.4 MARQUEE SIGN MS, MX GB, RC, CB, SMO | n/a | See Additional Standards | 5.7.9.G.7 & 5.7.10 PROJECTING SIGN RC | 1 | 32 | 5.7.9.G.8 MS, MX, SMO | 1 | 48 CB | 1 | 64 NOTES: [1] The cumulative sign area shall not exceed the maximum shown in Table 5.7.9.C: Attached Signs - Maximum Permitted Sign Area Per Principal Building Facade. [2] The maximum sign area for wall signs within the GCO is limited to 100 sf or the lesser sign area of the underlying zoning district. E. Attached Specialty Signs. The sign allowances for attached specialty signs, shall comply with the provisions in Table 5.7.9.E: Attached Specialty Signs - Maximum Permitted Sign Area by Sign Type. Attached specialty signs do not count towards the maximum sign allowances in Table 5.7.9.C: Attached Signs - Maximum Permitted Sign Area Per Principal Building Facade and Table 5.7.9.D: Attached Signs - Maximum Permitted Sign Area by Sign Type. Attached specialty signs are allowed in addition to other allowable attached signs. TABLE 5.7.9.E: ATTACHED SPECIALTY SIGNS - MAXIMUM PERMITTED SIGN AREA BY SIGN TYPE SPECIALTY SIGN TYPE | ZONING DISTRICTS | NUMBER | MAX SF | ADDITIONAL STANDARDS Blade Sign | All Nonresidential Districts | 1/entrance | 6 | 5.7.9.G.2 Crown Sign | OI, LB, GB, RC, CB, MS, MX, EC, LI, HI, SMO | 1/facade, max. 2/bldg. | 200 | 5.7.9.G.5 Freestanding Canopy Sign | All Nonresidential Districts | 1/canopy face | 10% of canopy face | 5.7.9.G.6 Roof Sign | CB, MX, SMO | 1/bldg. | n/a | 5.7.9.G.9 Supergraphic Sign | CB, MX District for market showroom use types only | n/a | n/a | 5.7.9.G.10 F. Attached Signs on Multi-Tenant Buildings. Signs on multi-tenant buildings, with 3 or more tenants and with separate tenant entrances, shall comply with the following standards: 1. The maximum sign area for each tenant shall be based on its proportionate share of building linear frontage in accordance with Table 5.7.9.C: Attached Signs - Maximum Permitted Sign Area Per Principal Building Facade; 2. Each attached tenant sign shall comply with all other applicable provisions in Table 5.7.9.D: Attached Signs - Maximum Permitted Sign Area by Sign Type; and 3. A common sign plan shall be submitted in accordance with Section 5.7.14, Common Sign Plan. G. Specific Standards for Attached Signs. The following standards apply to attached signs in additional to all other applicable standards. 1. Awning Sign. An awning sign shall comply with the following standards: a) The face of the awning structure shall determine the allowable sign size; (See Section 10.2.10, Signs, for rules of measurement) b) All awnings shall be of opaque material that does not transmit light through the awning; and c) External lighting may be placed above the awning. 2. Blade Sign. A Blade sign shall comply with the following standards: a) It shall be located on the building facade a minimum of 9 feet and a maximum of 15 feet above sidewalks and other pedestrian ways; and b) It may be internally or externally illuminated provided that cabinet signs are prohibited. 3. Building Banner Sign. A building banner sign shall comply with the following standards: a) It shall be oriented perpendicular to the building facade and shall be attached to a permanent structure on at least two ends; b) It shall not be illuminated; and c) No additional sign permit is required to change a building banner sign after the initial sign permit is issued and the pole mounts are approved, provided the approved pole mounts are not changed. 4. Building Canopy Sign. A building canopy sign shall comply with the following standards: a) It shall not exceed the vertical edge of the building canopy; b) It may extend beyond the top or bottom horizontal edges of the building canopy, or be within the face of the building canopy; c) If extended above the top horizontal edge, or on top of the building canopy, the maximum permitted height of the sign copy shall be 2 feet; and d) It may have internal illumination that is limited to cut-out letter/graphic or silhouette lighted signs. 5. Crown Sign. A crown sign shall comply with the following standards: a) It shall only be allowed on buildings 60 feet or greater in height; b) Only one crown sign shall be located on any one side of a building; c) No more than 2 crown signs shall be allowed per building; d) It shall not cover windows or architectural details; e) It shall not extend above the top of the roofline, or vertical edge of the building facade; f) It shall not be placed below the floor of the top floor of the building; g) It shall not exceed 75% of the width of the building facade; and h) It may have internal or external illumination, but internal illumination is limited to cut-out letter/graphic or silhouette lighted signs. 6. Freestanding Canopy Sign. A freestanding canopy sign shall comply with the following standards: a) It shall be located on the face of the canopy, or be suspended under the canopy; b) In no case shall it extend beyond the top horizontal or vertical edge of the canopy to which it is attached; c) It shall not be located on top of the canopy; and d) It may have internal illumination. 7. Marquee Sign. A marquee sign shall comply with the following standards: a) It may be internally or externally illuminated; b) It may have electronic changeable copy in accordance with the standards in Section 5.7.10, Electronic Sign Standards, up to a maximum height of 5 feet; and c) It may be located on top of the marquee with up to a maximum height of 3 feet and a maximum width of 75% of the marquee structure. When located on top of the marquee, it may have internal illumination that is limited to cut-out letter/graphic or silhouette lighted signs. 8. Projecting Sign. A projecting sign shall comply with the following standards: a) It shall be located on the building facade facing a street, drive, or pedestrian way; b) It shall be located a minimum of 15 feet above sidewalks and other pedestrian ways, and vehicular drives and parking spaces; c) It shall not include any loose, windblown or moving elements; d) It shall not extend horizontally more than 4 feet from the building facade; e) It shall not extend vertically above the roof line; f) It shall be separated from other projecting signs by a distance of at least 25 feet; g) Sign supports must be an integral part of the sign; and h) It may be internally or externally illuminated provided that cabinet signs are prohibited. 9. Roof Sign. A roof sign shall comply with the following standards: a) It shall be no more than 15 feet tall, including the support structure; b) It shall comprise only 65 percent of the roof width, or 40 feet, whichever is less; c) It shall only be placed on buildings at least 30 feet in height; d) It shall be limited to cut-out lettering only; e) It may have internal illumination that is limited to cut-out letter/graphic signs. f) No crown sign is permitted on the same building with a roof sign; g) It shall only be placed on flat roofs; h) It shall be set back from the edge of a roof at least 5 feet; and i) It shall be securely anchored in accordance with a licensed engineer's or sign manufacturer's specifications. 10. Supergraphic Sign. Supergraphic signs are intended to recognize the unique characteristics and needs of buildings or structures being used as market showrooms and the High Point Market. A supergraphic sign shall comply with the following standards: a) It shall not extend above the top of the roofline, or vertical edge of the building facade; b) It shall not cover windows or doors; c) It shall be securely anchored in accordance with a licensed engineer's or sign manufacturer's specifications; and d) It shall not be illuminated.

(Ord. No. 7266/17-08, § 21, 1-17-2017; Ord. No. 7286/17-28, § 3, 4-3-2017; Ord. No. 7365/17-108, § 8, 11-20-2017; Ord. No. 7622/20-38, § 17, 8-5-2020; Ord. No. 7912/23-27, § 1, 4-17-2023; Ord. No. 8064/25-42, § 1(Pt. I), 10-20-2025)

Ask a question about High Point law

Corpus searches the High Point sections it holds and shows the ones that match, with their citations. Free, no sign-in.