§ 8-2-54 — Regulations
Code of Ordinances of the City of High Point, North Carolina (Codified through Ordinance No. 8067/25-45, enacted November 17, 2025 (Supp. No. 9)) · High Point Code of Ordinances § 8-2-54
Corpus is an independent public-information project, not the official City of High Point website. Stable reference: corpuslaw.us/code/90ef53c4-1550-4b94-929c-a455041e01a2
Sec. 8-2-54. - Regulations.
(a) Prohibited discharge standards. (1) General prohibitions. No user shall contribute or cause to be contributed into the POTW, directly or indirectly, any pollutant or wastewater which causes interference or pass through. These general prohibitions apply to all users of a POTW whether or not the user is a significant industrial user or subject to any national, state, or local pretreatment standards or requirements. (2) Specific prohibitions. No user shall contribute or cause to be contributed into the POTW the following pollutants, substances, or wastewater: a. Any liquids, solids or gases which by reason of their nature or quantity are, or may be, sufficient either alone or by interaction with other substances to cause fire or explosion or be injurious in any other way to the POTW or to the operation of the POTW. Included in this prohibition are wastestreams with a closed cup flashpoint of less than 140 degrees Fahrenheit (60 degrees Celsius), using the test methods specified in 40 CFR 261.21. At no time, shall two (2) successive readings on an explosion hazard meter, at the point of discharge into the system (or at any point in the system) be more than five (5) percent nor any single reading over 10 percent of the lower explosive limit (LEL) of the meter. b. Solid or viscous substances in amounts which will cause interference with the flow in a sewer but in no case solids greater than one-half (½) inch in any dimension. c. Any wastes or water containing mineral or, hydrocarbon, vegetable or animal fats, wax, grease or oils, whether emulsified or not, in excess of 100 mg/l, or containing substances which may solidify or become viscous at temperatures between 32 degrees Fahrenheit and 150 degrees Fahrenheit. Animal and vegetable fats above these units may be allowed following written application and approval by the director. d. Any wastewater having a pH less than 5.0 or more than 11.0 or wastewater having any other corrosive property capable of causing damage or hazard to structures, equipment, and/or personnel of the POTW. e. Any wastewater containing pollutants, including oxygen demanding pollutants (BOD, etc.), in sufficient quantity (flow or concentration), either singly or by interaction with other pollutants, to pass through or interfere with the POTW wastewater treatment system, any wastewater treatment or sludge process, or constitute a hazard to humans or animals. f. Any noxious or malodorous liquids, gases, or solids or other wastewater which, either singly or by interaction with other wastes, are sufficient to create a public nuisance or hazard to life or are sufficient to prevent entry into the sewers for maintenance and repair. g. Any substance which may cause the POTW's effluent or any other product of the POTW such as residues, sludges, or scums, to be unsuitable for reclamation and reuse or to interfere with the reclamation process. In no case, shall a substance discharged to the POTW cause the POTW to be in noncompliance with sludge use or disposal regulations or permits issued under Section 405 of the Act, the Solid Waste Disposal Act, the Clean Air Act, the Toxic Substances Control Act, or state criteria applicable to the sludge management method being used. h. Any wastewater which imparts color which cannot be removed by the treatment process, such as, but not limited to, dye wastes and vegetables tanning solutions, which consequently imparts color to the treatment plants effluent thereby violating the POTW's NPDES permit. Color (in combination with turbidity) shall not cause the treatment plant effluent to reduce the depth of the compensation point for photosynthetic activity by more than 10 percent from the seasonably established norm for aquatic life. i. Any wastewater having a temperature greater than 150 degrees Fahrenheit (66 degrees Celsius), or which will inhibit biological activity in the POTW treatment plant resulting in interference, but in no case wastewater with the temperature at the introduction into the POTW to exceed 104 degrees Fahrenheit (40 degrees Celsius). j. Any wastewater containing any radioactive wastes or isotopes except as specifically approved by the POTW director in compliance with applicable state or federal regulations. k. Any pollutants which result in the presence of toxic gases, vapors or fumes within the system in a quantity that may cause worker health and safety problems. l. Any trucked or hauled pollutants, except at discharge points designated by the POTW director in accordance with section 8-2-65 of this article. m. Stormwater, surface water, groundwater, artesian well water, roof runoff, subsurface drainage, swimming pool drainage, condensate, deionized water, cooling water and unpolluted industrial wastewater, unless specifically authorized by the POTW director. n. Any industrial wastes containing floatable fats, waxes, grease or oils, or which become floatable at the wastewater temperature at the introduction to the treatment plant during the winter season, but in no case, industrial wastewater containing more than 100 mg/l of emulsified oil or grease unless authorized by the POTW director. o. Petroleum oil, non-biodegradable cutting oils, commonly called soluble oils, which form a persistent water emulsion, and non-biodegradable complex carbon compounds in amounts that will cause interference or pass through. p. Any sludges, screenings or other residues from the pretreatment of industrial wastes. q. Any medical wastes, except as specifically authorized by the POTW director in an industrial wastewater discharge permit. r. Any material containing ammonia, ammonium salts, or other chelating agents which will produce metallic complexes that interfere with the municipal wastewater system. s. Any material identified as hazardous waste according to 40 CFR Part 261 except as may be specifically authorized by the POTW director. t. Any wastewater causing the treatment plant effluent to violate state water quality standards for toxic substances as described in 15A NCAC 2B.0200. u. Recognizable portions of the human or animal anatomy. v. Any wastes containing detergents, surface active agents, or other substances which may cause excessive foaming in the municipal wastewater system. Pollutants, substances, wastewater, or other wastes prohibited by this section shall not be processed or stored in such a manner that these wastes could be discharged to the municipal wastewater system. All floor drains located in process or materials storage areas must discharge to the industrial user's pretreatment facility before connection with the system. When the POTW director determines that a user(s) is contributing to the POTW, any of the above enumerated substances in such amounts which may cause or contribute to interference of POTW operation or pass through, the director shall: (1) Advise the user(s) of the potential impact of the contribution on the POTW in accordance with subsections 8-2-54(a) and (b); (2) Take appropriate actions in accordance with section 8-2-60 for such user to protect the POTW from interference or pass through. (b) Polluted water control. All polluted water from homes, commercial establishments and manufacturing plants, whether such water is obtained from the city or not, when polluted by its use, shall be forced into the city's sanitary sewer system provided such wastes meet the requirements of this chapter. (c) Use of public sewers required. (1) It shall be unlawful for any person to place, deposit or permit to be deposited in any unsanitary manner on public or private property within the city or in any area under the jurisdiction of said city, any human or animal excrement, garbage or other objectionable waste. (2) It shall be unlawful to discharge to any natural outlet within the city or in any area under its jurisdiction, any sewage or other polluting materials, except where suitable treatment has been provided in accordance with applicable local, state and federal laws, ordinances and policies. In the event such polluting material is discharged, whether accidental or otherwise, it shall be the responsibility of the person causing the discharge. Where an objectionable or offending condition shall exist, as determined by the director, the person causing the discharge will immediately take corrective measures to remove or otherwise eliminate the offending condition in a manner approved by the director. In any unusual circumstances where an imminent threat to the health and safety of the public may deem to exist, or where corrective measures are not taken promptly by the person causing the offending condition, the director may then take such steps as he determines necessary to remove the polluting materials and eliminate the offending condition with such costs to be borne by the person causing such condition. (d) National Categorical Pretreatment Standards. (1) Users subject to categorical pretreatment standards are required to comply with applicable standards as set out in 40 CFR Chapter 1, Subchapter N, Parts 405 through 471 and incorporated herein. a. Where a categorical pretreatment standard is expressed only in terms of either the mass or the concentration of a pollutant in wastewater, the POTW director may impose equivalent concentration or mass limits in accordance with CFR 403.6(c). b. When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, the POTW director shall impose an alternate limit using the combined wastestream formula in 40 CFR 403.6(e). c. A user may obtain a variance from a categorical pretreatment standard if the user can prove, pursuant to the procedural and substantive provisions in 40 CFR 403.13, that factors relating to its discharge are fundamentally different from the factors considered by EPA when developing the categorical pretreatment standard. d. A user may obtain a net gross adjustment to a categorical standard in accordance with 40 CFR 403.15. e. A user may request a removal credit adjustment to a categorical standard in accordance with 40 CFR 403.7. (e) Local limits. To implement the general and specific discharge prohibitions listed in this article, industrial user-specific local limits will be developed ensuring that the POTW's maximum allowable headworks loading is not exceeded for particular pollutants of concern for each industrial user. Where specific local limits are not contained for a given parameter or pollutant in an industrial user permit, the following limits will apply to all users: Parameter | Limit (mg/l) BOD | 300 TSS | 200 Ammonia | 15 Cadmium (T) | 0.005 Chromium (T) | 0.050 Copper (T) | 0.050 Cyanide (T) | 0.010 Lead (T) | 0.050 Mercury (T) | 0.0005 Nickel (T) | 0.050 Silver (T) | 0.005 Zinc (T) | 0.10 Oil and grease | 100 Total Phosphorus | 5.0 pH range: Between 5.0 and 11.0 (standard units) (T) = Total Industrial user-specific local limits for appropriate pollutants of concern shall be included in wastewater permits and are considered pretreatment standards. (f) State requirements. State requirements and limitations on discharges shall apply in any case where they are more stringent than federal requirements and limitations or those in this article. (g) Right of revision. The city reserves the right to establish limitations and requirements which are more stringent than those required by either state or federal regulations if deemed necessary to comply with the objectives presented in section 8-2-52 of this article or the general and specific prohibitions in section 8-2-54 of this article, as is allowed by 40 CFR 403.4. (h) Dilution. No user shall ever increase the use of process water or, in any way, attempt to dilute a discharge as a partial or complete substitute for adequate treatment to achieve compliance with the limitations contained in the National Categorical Pretreatment Standards, unless expressly authorized by an applicable pretreatment standard, or in any other pollutant-specific limitation developed by the city or state. (i) Pretreatment of wastewater. (1) Pretreatment facilities. Users shall provide necessary wastewater treatment as required to comply with this article and wastewater permits issued under subsection 8-2-56(b) of this article and shall achieve compliance with all national categorical pretreatment standards, local limits, and the prohibitions set out in section 8-2-54(a) within the time limitations as specified by the EPA, the state, or the POTW director, whichever is more stringent. Any facilities required to pre-treat wastewater to a level acceptable to the city shall be provided, operated, and maintained at the user's expense. Detailed plans showing the pretreatment facilities and operating procedures shall be submitted to the city for review, and shall be acceptable to the POTW director before construction of the facility. The review of such plans and operating procedures will in no way relieve the user from the responsibility of modifying the facility as necessary to produce an effluent acceptable to the city under the provisions of this article. Any subsequent changes in the pretreatment facilities or method(s) of operation shall be reported to and be approved by the POTW director prior to the user's initiation of the changes. (2) Additional pretreatment measures. a. Whenever deemed necessary, the POTW director may require users to restrict their discharge during peak flow periods, designate that certain wastewater be discharged only into specific sewers, relocate and/or consolidate points of discharge, separate sewage wastestreams from industrial wastestreams, and such other conditions as may be necessary to protect the POTW and determine the user's compliance with the requirements of this article. b. The POTW director may require any person discharging into the POTW to install and maintain, on their property and at their expense, a suitable storage and flow-controlled facility to ensure equalization of flow. A wastewater discharge permit may be issued solely for flow equalization. (j) Grease control devices shall be installed on the premises where FOG is used or generated. (1) All commercial kitchens in new or existing buildings, undergoing significant improvement, undergoing remodeling or change in operations shall have grease control devices (GCD) as required by the Uniform Plumbing Code. If there is a size discrepancy in GCD installation (due to space limitations, etc.) a mutual agreement between the building department and industrial pretreatment department shall agree to compromise regarding size and fixtures to be discharged through the GCD. (2) All grease generating fixtures shall connect to a GCD, including but not limited to pre-rinse sinks, three-compartment sinks, two-compartment sinks, mop or janitor sinks, food preparation sinks, floor drains in dishwashing areas and kitchens, etc. All drainage fixtures in dishwashing room except for dishwashers shall connect to a GCD. (3) No high temperature kitchen equipment discharges shall be allowed to connect through any type of GCD. Discharge of wastewater from dishwashers, pasta cookers, other hot lines and non-grease generating fixtures to any GCD is prohibited unless authorized by the POTW director. (4) FSEs shall have a sink or other area for cleaning floor mats, containers, exhaust hood filters and equipment, which is connected to a GCD. The sink or cleaning area shall be large enough to clean the largest mat or piece of equipment to be cleaned. Outside washing of floor mats, equipment grills, or other containers is prohibited; this may allow contaminated wastewater to flow to the storm drain system. (5) All in-ground GCDs greater than 750 gallons in capacity shall have a minimum of three (3) manholes (refer to City of High Point Design Standards) to allow visibility over each inlet piping, baffle (divider) piping and outlet piping to ensure accessibility for inspection, cleaning and removal of all contents. Two (2) manholes may be allowed under certain conditions only granted by the city of High Point. Nothing shall be allowed to be stored on top of any GCD manholes. (6) In ground GCDs shall be installed in a suitable location that will allow access for inspection, cleaning, and maintenance. This includes drive-thru roads and parking stalls where inspection would be difficult or unsafe and impeded business operations. (7) Laterals installed between a FSE and GCD, also between the GCD and the city's main shall include installation of two-way clean outs as required to allow access points for sewer line maintenance and inspection. (k) Grease, oil and sand traps required for commercial and industrial establishments. (1) Grease, oil and sand traps shall be provided when, in the opinion of the city, they are necessary for the protection of sewerage system from liquid wastes containing petroleum based oils, fluids and greases in excessive amounts, or any flammable wastes, sand and other harmful pollutants not prohibited in section 8-2-54(a). Such traps shall not be required for buildings used solely for residential purposes. Such traps shall be required, for example, on discharges from all service stations, automotive repair garages, car washes, and other commercial or industrial establishments as the city may designate. (2) Users with the potential to discharge flammable substances may be required to install and maintain an approved combustible gas detection meter. (3) Grease control device maintenance requirements. a. All GCDs shall be kept in good repair, functioning properly and shall be maintained in continuous operation according to manufacturer's guidelines and the City of High Point's requirements. b. GCDs shall be maintained by the owner at the owner's expense. c. Sewer lines to and from GCDs shall be kept in good repair and clear of any buildup of FOG that could potentially contribute to backups and/or SSOs. d. All FOG discharged during GCD or sewer line cleaning and maintenance shall be captured. Any FSE that has their kitchen grease waste lines, exit lines from a GCD and/or laterals cleaned by jetting or hydro flushing shall have the contractor capture the contents removed from the line to prevent SSOs depending on the main size the lateral feeds into. All contents removed from sewer lines shall be contained and disposed properly by a licensed contractor. e. No additives may be introduced to GCDs or a FSE's wastewater system for the purpose of emulsifying FOG. Additives, such as solvents or enzymes that dissolve or mobilize FOG are prohibited. (4) GCD maintenance frequency. a. The maintenance frequency shall be set so as to ensure the minimum hydraulic retention time and required available hydraulic volume is maintained to effectively intercept and retain FOG and minimize the passage of FOG to the sanitary sewer collection system. The maintenance frequency for all FSEs with a GCD shall be determined by one (1) of the following methods: 1. GCDs shall be fully pumped out and cleaned at a frequency such that the combined FOG and solids accumulation does not exceed 25 percent of the total design hydraulic depth in any location of the GCD. The 25 percent rule shall apply to all GCDs. 2. The entire contents of all grease interceptors (gravity grease interceptors) and GCDs greater than 100 gallons shall be removed every three (3) months or more frequently as to prevent FOG from entering the sanitary sewer. 3. The entire contents of all grease traps (hydro mechanical grease interceptors and automatically or mechanically cleaning GCDs) shall be removed every month or more frequently as to prevent FOG from entering the sanitary sewer. b. The city may modify the maintenance frequency at any time to reflect changes in actual operating conditions. Based on the actual generation of FOG from the FSE, the maintenance frequency may increase or decrease. c. If the GCD, at any time, contains FOG and solids accumulation that does not meet the requirements in this section, the FSE shall have the GCD serviced immediately such that all FOG, solids, and other materials are completely removed from the GCD. d. Waste haulers servicing GCDs shall not reinsert or discharge into GCD, manhole, cleanout, or other sanitary sewer appurtenance any materials that the waste hauler has removed from the GCD or to cause those materials to be so handled. (5) Requirements for record keeping. a. GCD and plumbing record keeping. 1. The FSE shall retain all manifests, receipts and invoices of all cleaning, maintenance, grease removal of/from the GCD, disposal carrier and disposal site location for at least three (3) years. Such records, which include at a minimum of the following, shall be made immediately available for inspection and copying to the inspector or city representative upon request: 2. A logbook of grease interceptor, grease trap or grease control device cleaning and maintenance practices. 3. Copies of records of waste hauling GCD contents. The grease haulers shall leave, at the facility site, a manifest with the following information: • Name of site pumped. • Street address. • City name. • Date and time pumped. • Volume collected. • Hauler name. • Truck number. • Observed GCD structural problems. • Final destination of material collected. 4. Records of sampling data and sludge height monitoring for FOG and solids accumulation in the GCDs. 5. Records of any SSOs, backups, spills and/or cleaning of the lateral sewer system. 6. A record of best management practices being implemented including employee training. 7. Any other information deemed appropriate by the city to ensure and document compliance with this article. (6) Tallow bins. a. Segregation and collection of waste cooking oil. No person shall dispose of any grease, or cause any grease to be disposed, by discharge into any drainage piping, by discharge into any public or private sanitary sewer, by discharge into any storm drainage system, or by discharge to any land, street, public way, river, stream or other waterway. All waste cooling oils shall be collected and stored properly in tallow receptacles such as barrels or drums or bins for recycling or other acceptable methods of disposal. 1. Segregated waste grease and oil bins (tallow bins) shall be in place at the location of any FSE that creates grease or oil from the use of fryers, automatically or mechanically cleaning GCDs which need FSE staff maintenance, rotisserie drip lines not connected to a GCD or any other type of grease and oil waste created by cooking or cleaning of equipment. FSE staff, not limited to kitchen staff, shall properly dispose of grease or oils from cooking equipment into an oil/grease receptacle such as a tallow bin, barrel or drum. Appropriate measures shall be taken to eliminate spills. An absorption rag, towel, or material shall be immediately available each time the waste oil/grease is emptied to the tallow bin or segregated receptacle and used to clean up spills. The transporting of waste oil/grease shall be conducted with a covered and sealed container. 2. Tallow bins or used waste oil and grease container areas shall be kept clean. Containers shall be covered with lids and free from excessive fats, oil and grease and debris to prevent foul-smelling odors and vector attraction. Housekeeping procedures shall be put in place and signs posted. 3. Tallow bins shall be located in areas that reduce the risk of spills or discharges to the storm drain system. Where relocation is not possible, spill prevention should be implemented to prevent such discharges. (7) Tallow haulers. Tallow haulers servicing FSEs shall clean up all spills created during the collection and transporting of grease whether it is on the containers, bins, barrels or the ground. (8) Tallow bin record keeping. The FSE shall keep all manifests, receipts and invoices of all oil/grease removal from the FSE, disposal carrier and disposal site location for no less than three (3) years. The FSE shall, upon request, make the manifests, receipts and invoices available to any city representative or inspector. These records may include: a. A logbook of all segregated oil bins cleaning and maintenance practices. b. A record of best management practices being implemented including employee training. c. Copies of records and manifests of waste hauling activities. d. Records of any spills and/or cleaning. e. Any other information deemed appropriate by the city to ensure compliance with this article. (9) Best management practices—FSEs. All FSEs shall implement best management practices (BMPs). Emphasis shall be on minimizing the discharge of FOG to the sewer system and preventing non-stormwater discharges to the storm drain system. All FSEs shall be required, at a minimum, to provide staff training for the appropriate ordinance requirements and for the following kitchen BMPs: a. Install screens in all drains. The screens shall be installed to all sinks, drains, floor drains, floor sinks, dishwasher, etc. The screens shall be cleaned frequently by disposing waste to the trash or food scrap container if available. Regular inspections shall be conducted by lead managers and/or executive chefs to ensure screens are functioning properly and are present. It is recommended that the inspections be documented to confirm compliance and be available to the city representative or inspector upon request. b. Dispose of all food waste. Food waste shall not be disposed to sinks or drains. FSE staff shall dispose of all food waste directly into the trash, garbage, compost or food waste collection bins by scraping with scrapers, towels, paper towels and/or rubber spatulas prior to using water to rinse off plates, dishes, pots, pans, containers, etc. This practice helps remove FOG from entering the sanitary sewer system and GCDs. Properly dispose of food waste and solids in enclosed plastic bags prior to disposal in trash bins or containers to prevent leaking and odors. c. Maintain kitchen exhaust hood and equipment. Filters and other exhaust hood equipment shall be cleaned as frequently as necessary to maintain good operating condition. The wastewater generated from cleaning the exhaust filter shall be disposed properly and shall be cleaned in sinks connected to a GCD to ensure to capture of FOG prior to entering the sanitary sewer. d. Post signs and posters for best management and waste minimization practices conspicuously in the food preparation and dishwashing areas at all times. e. Clean all kitchen equipment and other equipment in the sinks or drains that flow directly into a GCD. Never clean equipment in a sink not connected to a GCD. f. Dry methods shall be used to clean up oil and grease spills. Pick up liquids or grease with rags or absorbents such as raw [saw] dust or cat litter. Sweep up absorbent, seal in a plastic bag and dispose in the trash. Regularly use dry methods to clean under fryer baskets and other locations where grease may be spilled or dripped. Clean up all oil and grease spills prior to mopping. If possible, always discharge waste mop water to a drain that will flow to a GCD. g. Dry sweep pavement, such as walkways, dining areas and dumpster areas as frequently as possible. h. Never pour, sweep or direct wash wastewater into a stormwater collection system, street or gutter. If any pavement cleaning requires water, sweep first; next use a mop without soap and bucket and dispose of wash wastewater in a sink that drains to a GCD. i. Never wash down dumpsters or tallow bins with a hose. If a dumpster or tallow bin must be cleaned, contact the dumpster or tallow bin vendor. Check dumpsters and tallow bins frequently for leaks. Notify the dumpster or tallow bin vendor to maintain and replace leaking dumpsters or tallow bins. (l) Accidental discharge /slug control plans. The POTW director shall evaluate whether each significant industrial user needs a plan or other action to control and prevent slug discharges and accidental discharges as defined in section 8-2-53(a). All SIUs must be evaluated within one (1) year of being designated an SIU. The POTW director may require any user to develop, submit for approval, and implement such a plan or other specific action. Alternatively, the POTW director may develop such a plan for any user. (1) All SIUs are required to notify the POTW immediately of any changes at its facility affecting the potential for spills and other accidental discharge, discharge of a non-routine, episodic nature, a non-customary batch discharge, or a slug load. Also see subsections 8-2-57(f) and (g). (2) An accidental discharge/slug control plan shall address, at a minimum, the following: a. Description of discharge practices, including non-routine batch discharges; b. Description of stored chemicals; c. Procedures for immediately notifying the POTW director of any accidental or slug discharge, as required by subsection 8-2-57(g) of this article; and d. Procedures to prevent adverse impact from any accidental or slug discharge. Such procedures include, but are not limited to, inspection and maintenance of storage areas, handling and transfer of materials, loading and unloading operations, control of plant site runoff, worker training, building of containment structures or equipment, measures for containing toxic organic pollutants, including solvents, and/or measures and equipment for emergency response. e. Flow and loading equalization. In order to promote the equalization of flows and any constituent loadings, including but not limited to BOD and TSS on the sewer system, each person whose operations produce wastewaters having widely fluctuating flows or constituents is required to install and maintain at his own expense, a suitable storage or holding tank. The holding tank shall have a minimum capacity of 75 percent of the user's average daily flow, except that no tank shall be less than 1,000 gallons. Suitable air mixing will be required to keep solids in suspension and maintain aerobic conditions. Such holding or storage tank, air mixing system and any outlet device controlling the discharge of wastes to the sanitary sewer shall be approved by the director. f. Monitoring facilities. 1. To facilitate observations, flow measurements and sampling of liquid wastes discharged to the city's sanitary sewer, any person who discharges or proposes to discharge liquid wastes into the city's sanitary sewer shall construct a suitable monitoring facility, located on the building sewer and downstream from any pretreatment works, provided: (a) The BOD concentration exceeds 300 mg/l; (b) The TSS concentration exceeds 250 mg/l; (c) The average flow per work day exceeds 25,000 gallons; or (d) The manufacturing processes produce toxic or poisonous wastes such as but not limited to cyanides, heavy metals, insecticides, herbicides, etc. 2. All industrial users that are subject to categorical pretreatment standards will also be required to provide and operate, at the user's own expense, monitoring facilities for flow measurement and any sampling required by the director or the categorical pretreatment standards. Plans for the location and construction of the monitoring facilities shall be approved by the director prior to commencing the installation. (m) Dental facilities. As promulgated by the Environmental Protection Agency, and as incorporated below, dental facilities that use or remove amalgam must install, operate and maintain, at user's expense, one (1) or more amalgam separators that meet established standards and record keeping requirements listed under 40 CFR Part 441. (1) Amalgam separators required. a. Dental facilities that use or remove amalgam must install, operate and maintain at user's expense, one (1) or more amalgam separators or amalgam removal device(s) that meet the following requirements: 1. Compliant with American National Standards Institute (ANSI) American National Standard/American Dental Association (ADA) Specification 108 for Amalgam Separators (2009) with Technical Addendum (2011); or 2. Compliant with the International Organization for Standardization (ISO) 11143 Standard (2008) or subsequent versions if the separators achieve at least a 95 percent removal efficiency. 3. Amalgam removal device, other than an amalgam separator shall have a removal efficiency of at least 95 percent from all amalgam process wastewater. Removal efficiency and performance testing information is outlined in 40 CFR Part 441.30(a)(2)(i) through (viii). (2) Implementation of the following best management practices (BMPs): a. Waste amalgam including, but not limited to, dental amalgam from chairside traps, screens, vacuum pump filters, dental tools, cuspidors, or collection devices, must not be discharged to a POTW. b. Dental unit water lines, chair-side traps, and vacuum lines that discharge amalgam process wastewater to a POTW must not be cleaned with an oxidizing or acidic cleaners, including but not limited to bleach, chlorine, iodine and peroxide that have a pH lower than six (6) or greater than eight (8). (3) Dental dischargers that meet any of the criteria below are exempt from this subsection: a. Dental dischargers that exclusively practice one (1) or more of the following specialties are exempt from these requirements: 1. Oral pathology. 2. Oral and maxillofacial radiology. 3. Oral and maxillofacial surgery. 4. Orthodontics. 5. Periodontics. 6. Prosthodontics. b. Mobile unit operated by a dental discharger. c. Dental dischargers that do not discharge any amalgam process wastewater to a POTW because amalgam process wastewater is collected and transferred to a centralized waste treatment facility as defined in 40 CFR Part 437. d. Dental dischargers that do not place dental amalgam, and do not remove amalgam except in limited emergency or unplanned, unanticipated circumstances, and that certify to such to the control authority as required in subsection (m)(4)a.2.ii. (4) Reporting and recordkeeping requirements. a. Dental dischargers subject to this part must comply with the following reporting requirements: 1. One-time compliance report. i. A one-time compliance report must be submitted to the control authority no later than 90 days following introduction of wastewater into a POTW. 2. Signature and certification. i. The one-time compliance report must be signed and certified by a responsible corporate officer, a general partner or proprietor if the dental discharger is a partnership or sole proprietorship, or a duly authorized representative in accordance with the requirements of sections 8-2-53(a) and 8-2-56(b)(3). ii. The one-time compliance report for dental dischargers subject to this part that do not place or remove dental amalgam as described in subsections (m)(3)a.—d. and must include the following: (a) Facility name. (b) Physical address. (c) Mailing address. (d) Contact information. (e) Name of the operator(s) and owner(s). (f) Certification statement that the dental discharger does not place dental amalgam and does not remove amalgam except in limited circumstances. iii. The one-time compliance report for dental dischargers subject to the standards of this subsection must include the following information: (a) The facility name. (b) Physical address. (c) Mailing address. (d) Contact information. (e) Name(s) of the operator(s) and owner(s). (f) A description of the operation at the dental facility including: (1) The total number of chairs. (2) The total number of chairs at which dental amalgam may be present in the resulting wastewater. (3) A description of any existing amalgam separator(s) or equivalent device(s) currently operated to include at a minimum, the make, model and year of installation. (g) Certification that the amalgam separator(s) or equivalent device is designed and will be operated and maintained to meet the requirements specified in subsections (m)(1)a.1. and 2. or (m)(4). (h) Certification that the dental discharger is implementing BMPs specified in subsections (m)(2) or (m)(4) and will continue to do so. (i) The name of the third-party service provider that maintains the amalgam separator(s) or equivalent device(s) operated at the dental office, if applicable. Otherwise, a brief description of the practices employed by the facility to ensure proper operation and maintenance in accordance with subsections (m)(1)a.1. and 2. or (m)(4). iv. Transfer of ownership notification. (a) If a dental discharger transfers ownership of the facility, the new owner must submit a new one-time compliance report to the control authority no later than 90 days after the transfer. v. Retention period. (a) If a dental discharger subject to this subsection is in operation, or until ownership is transferred, the dental discharger or an agent or representative of the dental discharger must maintain the one-time compliance report required by subsection (m)(4)a.1. and make it available for inspection in either physical or electronic form. (b) Dental dischargers or an agent or representative of the dental discharger must maintain and make available for inspection in either physical or electronic form, for a minimum of three (3) years: (1) Documentation of the date, person(s) conducting the inspection, and results of each inspection of the amalgam separator(s) or equivalent device(s), and a summary of follow-up actions if needed. (2) Documentation of amalgam retaining container or equivalent container replacement (including date as applicable). (3) Documentation of all dates that collected amalgam is picked up or shipped for proper disposal in accordance with 40 CFR 261.5(g)(3), and the name of the permitted or licensed treatment, storage or disposal facility receiving the amalgam retaining containers. (4) Documentation of any repair or replacement of an amalgam separator or equivalent device, including the date, person(s) making the repair or replacement and a description of the repair or replacement (including make and model). (5) Dischargers or an agent or representative of the dental discharger must maintain and make available for inspection in either physical or electronic form, the manufacturer's operating manual for the current device.
(Ord. No. 6486/07-81, § 1, 9-20-07; Ord. No. 6965/12-81, 12-17-12; Ord. No. 7609/20-25, 5-18-20)
Ask a question about High Point law
Corpus searches the High Point sections it holds and shows the ones that match, with their citations. Free, no sign-in.