Sec. 9-2-6. - Electrical code.

(a) Boundaries, code defined. There are hereby established electrical regulations for the city and the Guilford County portion of the city's extraterritorial area (hereafter referred to as the "environs"), which shall be known as the City of High Point, North Carolina and Environs Electrical Code (hereinafter referred to as the "electrical code" or this "code"). (b) National code adopted. The National Electrical Code, 1984 edition, adopted by reference in North Carolina State Building Code, Volume IV, "Electrical" is hereby adopted and made applicable to the area within the corporate limits of the city and the area within the extraterritorial area of the city (hereinafter referred to as the "environs"). The code is hereby incorporated and made a part hereof as if it were set out in full herein, and three (3) copies of the code are on file with the city clerk. (c) Installation standards. All installations shall be in conformity with the provisions of the laws of the state governing electrical wiring installations and materials and this section. (d) Special rules. (1) The provisions of this chapter shall be applicable to all outdoor lighting except where such lighting is owned and operated by a public utility company. Before any outdoor lighting is installed, plans shall be submitted to the electrical inspector for approval and a permit secured. All lighting shall be installed in accordance with this provision of this chapter, and the lights shall be located and maintained so as not to constitute a nuisance or interfere with the safety or general welfare of the public or adjoining property owners. All outdoor lighting shall conform to the National Electrical Code and this Code. (2) Where the building construction is of brick veneer exterior, the electrical contractor shall install a suitable anchorage to the framework to support the service drop so that no strain will be applied to the brick veneer. The service drop bracket or fixture shall be secured by means of screws, bolts or lags. Nails shall not be used in any case. (e) Five local option rules supplementing the National Electrical Code revised by the North Carolina State Building Code Council, June 13, 1978. The following rules are intended to apply to permanent buildings or structures covered by the National Electrical Code: (1) All wiring on or in permanent buildings or structures located within a primary fire district shall utilize approved metal raceways or metal jacketed cables such as MI or type MC Metal—Clad (type A.C. not allowed) as permitted by the National Electrical Code. (2) All permanent buildings, wherever situated, which are required to have an emergency system power source by the state building code shall have the service entrance conductors enclosed in approved raceway; and, in addition to the above, all portions of the required emergency lighting system for the entire building shall be wired in metal raceway, nonmetallic raceways encased in not less than two (2) inches of concrete, mineral-insulated metal-sheathed cable, or type MC cable as permitted by the state electrical code. The total area of any specific place of assembly shall include the area of balconies and the area of connecting rooms with movable partitions. Exceptions to Rules 1 and 2. Sound equipment, communication circuits. Class 2 and Class 3 remote control and signal circuits, and fire protection signaling circuits as permitted in the National Electrical Code. (3) Each individual gasoline pump, dispenser, lighting standard or other electrical devices located where gasoline or other volatile flammable liquids or liquefied flammable gases are transferred to the fuel tank or any motor vehicle shall be supplied through an individual rigid metal conduit. The above is not intended to prohibit the consolidation of such individual conduits outside of the hazardous areas, or consolidation within an approved junction box flush with the dispensing inland surface. (4) Service equipment shall not be located in any attic, clothes closet, kitchen storage cabinet, bathroom, toilet room, coal or trash bin. (5) All panelboards which have spare pole spaces or space over-current devices and are set flush in masonry or finished walls shall be provided with at least one-inch approved raceway or other equivalent provision for future extension. Such raceways, when required, shall be installed to the basement, crawl space, accessible ceiling space or attic, or to a junction box in the ceiling or side wall at the ceiling line. (f) Two or more switches or meters grouped at one location. Where two (2) or more switches or meters are grouped at one (1) location, each switch or meter outlet shall be permanently marked to show the section of building or apartment served. These markings shall be painted or stenciled. (g) Liability for damage. This section shall not be construed to relieve from or lessen the responsibility or liability of any party owning, operating, controlling or installing any electrical wiring, devices, appliances or equipment for damages to person or property caused by any defect therein; nor shall the city be held as assuming any such liability by reason of the inspection authorized herein or the certificate of approval issued as herein provided.

(Ord. No. 7206/16-26, § 4, 5-16-16)

Ask a question about High Point law

Corpus searches the High Point sections it holds and shows the ones that match, with their citations. Free, no sign-in.