Sec. 26-122. - Fats, oils and grease control.

(a) Grease interceptors. (1) All new food service establishments shall install a minimum one thousand-gallon in-ground grease interceptor. Grease interceptors may also be required at non-cooking establishments and other industrial, commercial, or institutional establishments at the person, firm or corporation's expense when deemed necessary by the public services director for the proper handling of grease-laden wastewaters, based on his/her review of data supporting such requirement in order to fulfill the requirements of the city sewer use ordinance (chapter 26). All grease interceptors shall be of a type, design, and capacity approved by the director and shall be readily and easily accessible for cleaning and city inspections and sampling. The following information shall be submitted to the city public services department prior to issuance of building permits: a. Plumbing drawings for the proposed facility signed and sealed by a licensed engineer. b. Identification and dimensions in inches for each compartment of each drainage unit. c. Dishwasher contribution in GPM. d. Pulper contribution in GPM. e. Drain specification (pipe diameter). f. Name of engineering firm or supplier who sized "grease interceptor." g. Grease interceptor information including: supplier, type, size, calculations used to determine detention time. h. Flow control device information. i. Statement/disclaimer on plans indicating proposed interceptor will meet or exceed current plumbing codes. (2) No new food service establishment shall be allowed to initiate operations until grease handling facilities are installed and approved by the public services department. (3) A minimum hydraulic retention time must be provided between the influent and effluent baffles of twenty-four (24) minutes of actual peak flow or twelve (12) minutes at the calculated theoretical peak flow rate, as predicted by the Uniform Plumbing Code fixture criteria. In addition to the minimum hydraulic retention requirement, twenty (20) per cent of the total volume of the grease interceptor shall be allowed for sludge to settle and accumulate. (4) Existing food service establishments prior to adoption of this section that do not have grease interceptors meeting the standards set forth herein shall be evaluated on a case-by-case bases with reference to subsection (a). (5) Food service establishments shall not use biological additives, enzymes, grease solvents, emulsifiers, etc. as a grease degradation agent. (6) Exterior in-ground grease interceptors, at the food service establishment's expense, shall be serviced and emptied of the waste content as required, but at least every thirty (30) days to prevent blockages by fats, oils or grease. Servicing on a greater than thirty-day schedule requires prior written approval from the public services director. In-floor and under-the-sink grease interceptors shall be cleaned at least weekly. (7) Grease interceptors shall be kept free of inorganic solid materials such as rocks, grit, gravel, sand, eating utensils, cigarettes, shells, towels, rags, etc., which could settle and reduce the effective volume of the grease interceptor. (8) Food service establishments shall supply an adequate sampling point downstream of the grease interceptor, prior to mixing with other sanitary flows. The minimum requirement for the sampling point shall be a four-inch sanitary tee installed on the interceptor's outlet side, subject to plan review and approval. (9) The public services director reserves the right to make determinations of grease interceptor adequacy and need, based on review of all relevant information regarding grease interceptor performance, facility site and building plan review, and to require repairs to, or modification or replacement of such grease interceptors, in keeping with applicable laws, regulations, and ordinances, including but not limited to the sewer use ordinance. (b) Existing food service establishment. (1) Food service establishments without any grease handling measures in place will be given a compliance deadline not to exceed six (6) months from the date of notification to have approved and installed grease-handling equipment in compliance with this section, this six-month time period will begin only after city staff can show just cause that the establishment is in violation of the sewer use ordinance. (2) For cases in which "outdoor" type grease interceptors are infeasible to install, existing food service establishments shall be required to install adequate and approved "under the counter" grease traps, approved by the public services director for use on individual fixtures including dishwashers, sinks and other potential grease containing drains. (c) New food service establishment in existing buildings. (1) Where practical, as determined by the public services director, new food service establishments locating in existing buildings shall be required to comply with the grease interceptor standards applicable to all new food service establishments. (2) Where it is physically impossible to install "outdoor" interceptors, "under the counter" interceptors may be allowed for existing food service establishments provided prior approval of unit type, size, location, etc. are obtained from the city's public services department. (d) Grease interceptor inspections. (1) All food service establishments shall maintain a written record of all interceptor maintenance activities for a period of three (3) years. A copy of the monthly service ticket shall be provided to the public services grease trap technician no later than the fifteenth day of the month following service. These records shall include: a. Food service establishment name and physical location; b. Date of grease interceptor service; c. Time of grease interceptor service; d. Name of grease interceptor company; e. Name and signature of grease interceptor service company agent performing said service; f. Established service frequency and type of service: full pump out, partial pump out, on-site treatment (type and nature of operations); g. Number and size of each grease interceptor serviced at food service establishment location; h. Approximated amount, per best professional judgment of contract service provider, of grease and solids removed from each grease interceptor; i. Destination of removed wastes, food solids, and wastewater disposal; j. Signature and data of food service establishment personnel confirming service completion; k. Such other information as required by public services director. (2) During inspection by applicable city staff, grease caps and solids measurements will be performed. Grease accumulation shall not be greater than four (4) inches at any point within the grease interceptor. Solids accumulation shall not be greater than twenty (20) per cent of the total water depth from the grease interceptor's interior floor to the static working water level, at any point within the grease interceptor.

(Ord. No. 94-12, 4-5-94; Ord. No. 99-35, 6-8-99; Ord. No. 10-31, 4-20-10)

Ask a question about Jacksonville law

Corpus searches the Jacksonville sections it holds and shows the ones that match, with their citations. Free, no sign-in.