Sec. 17-4. - Water and sewer service in subdivisions or multiunit complexes.
(a) General conditions. Construction of all water and sewer systems that are to be connected to the city system shall be in accordance with city specifications. All costs of such systems shall be borne by the developer. (b) Plans and specifications. Three (3) sets of plans and specifications for water and sewer shall be submitted to the city and approved prior to beginning work on any project that will connect to the city's system. The city will apply for any approval required by the state, and all costs shall be borne by the developer. All plans shall be prepared by a professional engineer licensed to practice in North Carolina. All construction shall be performed by a contractor licensed to perform this type of work in the State of North Carolina. (c) Inspections. Inspection by city personnel will be performed in all work which will be connected to the city system, including point of connection to the city lines by others. Costs of inspection will be borne by the developer, based on the inspection fee schedule. Tests required by the city to determine compliance with city specifications and standards shall be borne by the developer. (d) Rights-of-way. The city requires a recorded right-of-way on all mains which will be owned or maintained by the city outside of dedicated street rights-of-way. No other utility will be in the city right-of-way, unless by permission, in writing, granted by the city. (e) Preconstruction conference. A preconstruction conference shall be held between the city and the developer's authorized representative prior to the commencement of any construction. (f) Completion, testing, acceptance. No water or sewer services, except for purposes of temporary construction, will be authorized in any new area until the project has been completed, tested and accepted by the city and rights-of-way have been provided. (g) Installation of water mains. All water mains shall be installed in accordance with specifications of the North Carolina Department of Human Resources, Division of Health Services, Water Supply Branch, as well as the city's specifications. (h) Water main sizes and locations. All water main sizes shall be a minimum of six (6) inches in diameter, unless approved otherwise by the approving authority. Larger size mains may be required for future expansion. A water main shall be installed on all frontage that abuts a dedicated street. (i) Location of fire hydrants. Fire hydrants shall be installed so as to provide protection to all dwellings within a four hundred-foot radius of the hydrant. (j) Point of delivery. The city will deliver water service at a point approved by the city. This point generally is at the street right-of-way. If deemed advantageous to the city, the city may accept water mains within dedicated rights-of-way inside a subdivision or multiunit complex. (k) Sewer main size. All sewer mains shall be a minimum of eight (8) inches in diameter. Larger size mains may be required for future expansion. (l) Installation of sewer mains. All sewer mains shall be installed in accordance with specifications of the North Carolina Department of Natural Resources and Community Development and with city specifications.
(Ord. of 4-24-89, §§ I, II)
Ask a question about Kannapolis law
Corpus searches the Kannapolis sections it holds and shows the ones that match, with their citations. Free, no sign-in.