§ 8-2009 — NEW OR REPLACEMENT WATER AND SEWER SYSTEMS TO BE FLOOD-RESISTANT
Code of the City of Raleigh (Supp. No. 69: codified through Ordinance No. (2025) 802, adopted October 21, 2025) · Raleigh City Code § 8-2009
Corpus is an independent public-information project, not the official City of Raleigh website. Stable reference: corpuslaw.us/code/e6bd8e6c-6495-47c5-8012-a47a3d398fff
Sec. 8-2009. - NEW OR REPLACEMENT WATER AND SEWER SYSTEMS TO BE FLOOD-RESISTANT.
(a) Any and all new or replacement water supply systems and sanitary sewage systems within floodprone areas shall be designed and constructed to minimize and eliminate infiltration of floodwaters into such systems and to minimize and eliminate discharges from such systems into floodwaters. (b) Any and all on-site new waste disposal systems within floodprone areas shall be located, designed and constructed so as to avoid impairment of them or contamination from them during flooding. (c) Any venting of any sanitary sewer system and nonwatertight manholes shall be constructed to a height at least three (3) feet above the 100-year flood elevation provided nothing herein shall prevent the construction of watertight manholes below the 100-year flood elevation.
(Code 1959, §23-35; Ord. No. 1978-872-TC-88, §§16—19, 8-15-78; Ord. No. 2014-262, §10, 1-21-14, eff. 1-26-14)
Ask a question about Raleigh law
Corpus searches the Raleigh sections it holds and shows the ones that match, with their citations. Free, no sign-in.
