§ 11-10 — Minimum standards
Code of Ordinances of the City of Rocky Mount, North Carolina (Codified through Ordinance No. O-2025-71, enacted November 10, 2025. (Supp. No. 90)) · Rocky Mount City Code § 11-10
Corpus is an independent public-information project, not the official City of Rocky Mount website. Stable reference: corpuslaw.us/code/e30b01bc-ac6f-4abd-94b0-6e204977240e
Sec. 11-10. - Minimum standards.
Without excluding other ways and means of determining that a dwelling is unfit for human habitation, the code enforcement official shall apply the minimum standards set forth in section 11-10 of this Code in determining whether a dwelling is unfit. (a) Facilities. (1) Sanitary. Every dwelling shall be furnished with a potable water supply system. "Potable water supply" shall mean direct connection to a well, to a public water utility or equivalent water service delivery system, and does not include water delivered through a hose or via containers. Every dwelling shall contain not less than a kitchen sink, lavatory, tub or shower, and a water closet all in good working condition and properly connected to an approved water and sewer system. Every plumbing fixture and water and waste pipe shall be properly installed and maintained in good sanitary working condition free from defects, leaks, and obstruction. "Properly connected" means connected with approved plumbing materials (no radiator hose, duct tape, etc.). "Properly installed" means continuous piping that met the North Carolina State Building Code in effect at the time of installation. Any new, additional or repair plumbing must meet the current requirements of the North Carolina State Building Code. Provided, however, that the kitchen sink standards enumerated herein shall not apply to hotels, motels and other transient places unless kitchen sinks are otherwise required. (2) Location of sanitary facilities. All required plumbing fixtures shall be located within the dwelling and be accessible to the occupants of same. The water closet, tub or shower and lavatory shall be located in a room (or adjoining rooms) affording privacy to the user. Required bathrooms shall be accessible from habitable rooms, hallways, corridors or other protected or enclosed areas. (3) Hot and cold water supply. Every dwelling shall have connected to the kitchen sink, lavatory, and tub or shower an adequate supply of both cold and hot water. All water shall be supplied through an approved distribution system connected to a potable water supply. (4) Water heating. a. Every dwelling shall have water heating facilities which are properly installed and maintained in a safe and good working condition and are capable of heating water to such a temperature so as to permit hot water to be drawn consecutively (that is, at one (1) tap after the other, and not simultaneously) at every required kitchen sink, lavatory basin, bathtub or shower at a temperature of not less than one hundred sixteen (116) degrees Fahrenheit. Such water heating facilities shall be capable of meeting the requirements of this subsection when the dwelling's heating facilities required under the provisions of the code are not in operation. Apartment houses may use a centralized water heating facility capable of delivering an amount of hot water in the quantity and at the temperature described above. b. Water heaters shall be equipped with approved relief valves, which are piped to a point not more than six (6) inches above the floor. The pipe material for the relief valve shall be threaded pipe approved for interior water service lines. c. Provided, however, that the provision in subsection (a)(4) of this section for hot water supplies for a kitchen sink shall not apply to hotels, motels, and other transient dwellings where kitchen sinks are not required. (5) Heating. a. Every dwelling shall have heating facilities which are properly installed, are maintained in safe and good working conditions, and are capable of safely and adequately heating one (1) habitable room, excluding the kitchen in every dwelling regulated herein to a temperature of at least sixty-eight (68) degrees Fahrenheit at a distance three (3) feet above floor level, during ordinary winter conditions. Each heating system shall have at least one (1) readily adjustable control for regulation of living space temperature in each dwelling unit. Radiator control knobs in good working order shall be regarded as a readily adjustable control. If heat is not provided in every habitable room, the dwelling shall be provided with sufficient fireplaces, chimneys, flues or gas vents whereby heating appliances may be connected so as to heat all habitable rooms and bathrooms to a temperature of sixty-eight (68) degrees Fahrenheit at a distance three (3) feet above the floor level during ordinary winter conditions. b. Where a central heating system is not provided for a dwelling, the dwelling shall be provided with properly installed baseboard electric heat, properly installed and properly vented wood or fossil fuel heater(s), or unvented natural gas heater(s) having oxygen depletion sensors listed for residential use by UL, ETL, or other recognized testing laboratory and installed in strict accordance with the manufacturer's instructions. c. The following heating devices do not meet the requirements of subsections (5)a. and (5)b. of this section: 1. Portable electric heating units; and 2. Unvented fuel-burning heaters. d. The use of unvented fuel-burning heaters is prohibited in any bedroom. (6) Chimneys. a. Chimneys must be safe for use as specified and intended. "Specified" means use in connection with specific heating appliance or systems, or limitations of such use. "Intended" means use in connection with combustion of fuel, for which the following minimum chimney standards apply: 1. Flue liner intact; 2. Chimney mortar and bricks secure; 3. Flue unobstructed; 4. Fireplace bricks intact; 5. Stove piping placed and secured with clearances as follows: (i) Minimum twelve-inch brick clearance separation from combustibles; or (ii) Minimum nine-inch air separation for insulated listed stove piping; or (iii) Minimum one-inch air clearance surrounded by six-inch glass fiber insulation and ventilated thimble assembly; or (iv) Minimum two-inch air separation for insulated listed stove piping with one-inch air space between inner and outer chimney components; and as otherwise described in National Fire Protection Association Standard 211 (NFiPA), "Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances". 6. Heating appliance clearances maintained at thirty-six (36) inches from combustible materials and/or surfaces, except that clearances may be reduced as provided in NFiPA Standard 211, "Chimneys Fireplaces, Vents and Solid Fuel-Burning Appliances". b. Chimneys that do not meet these standards shall either be repaired or sealed. (7) Cooking equipment. All cooking equipment and facilities shall be installed in an approved manner. Portable cooking equipment employing flame is prohibited as a substitute for approved cooking equipment. Portable cooking equipment is prohibited outside the kitchen area of a boarding or rooming house. (8) Smoke detector systems. Every dwelling or dwelling unit shall be provided with an approved U.L. listed smoke detector on each level of the dwelling and in interior enclosed stairwells, hallways, and other common areas of multiple-unit dwellings, installed in accordance with N.F.P.A. 72 and the manufacturer's recommendations and listings. Dwellings constructed after July 1, 1975, and prior to January 1, 1999, shall be equipped with a 110-volt hard-wired smoke detector installed in accordance with the North Carolina State Building Code. Dwellings or dwelling units constructed after January 1, 1999, shall be equipped with listed 110-volt hard-wired interconnecting smoke detector(s) with battery back-up installed inside every sleeping room and in the area outside of each sleeping room in accordance with the North Carolina State Building Code. When battery-operated smoke detectors are allowed by this code or the North Carolina State Building Code, batteries shall be replaced at least once annually. (9) Street address. Each dwelling shall bear a street address number of a color contrasting with the surface on which the number is mounted, such number shall be of sufficient size to be visible from the nearest public street, but not less than three (3) inches in height. If the dwelling is not visible from the nearest public street, a sign or standard bearing the address number shall be placed on the principle public street access point to the dwelling, such number to meet the standards set forth herein. (b) Light and ventilation. (1) Windows. Every habitable room shall have at least one (1) window or skylight facing directly to the outdoors. The minimum total window area measured between stops, for every habitable room shall be eight (8) percent of the floor area of such room. Whenever walls or other portions of structures face windows of any such room and such light-obstruction structures are located less than three (3) feet from the window and extend to a level above that of the ceiling of the room, such a window shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area. Whenever the only window in a room is a skylight-type window in the top of such room, the total window area of such skylight shall equal at least fifteen (15) percent of the total floor area of such room. (2) Ventilation. a. Every habitable room (except kitchens with exhaust fans in good working order) shall have at least one (1) window or skylight which can easily be opened. The total of openable window area in every habitable room shall be equal to at least forty-five (45) percent of the minimum window area size or minimum skylight-type window size, as required, or shall have other approved, equivalent ventilation. b. Year-round mechanically ventilating conditioned air systems may be substituted for windows, as required herein, in rooms other than rooms used for sleeping purposes. Window type air conditioning units are not included in this exception. (3) Bathroom. a. Every bathroom shall comply with the light and ventilation requirements for habitable rooms except that no window or skylight shall be required in adequately ventilated bathrooms equipped with an operable ceiling electrical exhaust fan. (4) Lighting in halls and stairways. a. Every hall and stairway of every dwelling, shall be lighted, including exterior stairways and stairways in halls and public space. Every interior stairway shall have a three-way wall switch at the top and bottom of the stairs. (c) Electrical systems. (1) Electrical service. Adequate electric service must be provided to the dwelling. "Adequate" means a [minimum] of one hundred (100) ampere service. If the connected electrical load exceeds the capacity of a one hundred (100) ampere service, a service of sufficient capacity to safely bear the connected load shall be furnished. "Edison base" fuses shall not be permitted as components of any modified or updated electrical service, and no more than one (1) two-wire branch circuit shall be connected to any fuse, circuit breaker or other approved over current protection device. Drop cords from a neighboring source, generator or similar source are not "adequate" for the purpose of this code. Every new or additional electrical outlet and fixture required by the code shall be installed, maintained and connected to a source of electric power in accordance with the provisions of the North Carolina State Building Code. If the connected electrical load exceeds the capacity of a one hundred (100) ampere service, a service of sufficient ampere capacity to safely bear the connected electrical load shall be furnished. If it can be demonstrated to the satisfaction of the city inspection services administrator or his designee that an electrical service of a lesser size than a one hundred (100) ampere service is adequate to serve a structure, that electrical service will be approved. In this case, "adequate" means that the service conforms to the standards of National Electrical Code, does not have more than one (1) two-wire branch circuit connected to any fuse or circuit breaker, shows no signs of damage, overfusing or tampering and calculations provided show the existing service is adequate for the loads imposed. (2) Lights and outlets. a. Every habitable room or space shall contain at least two (2) separate and remote duplex receptacle outlets. b. Bedrooms shall have, in addition, at least one (1) wall switch controlled lighting outlet or ceiling light fixture or permanent fixture controlled by a pull chain. c. In kitchens, three (3) separate, remote and accessible receptacle outlets shall be provided, and a wall or ceiling lighting outlet controlled by a wall switch or fixture pull-chain shall be provided. An outlet dedicated to powering an appliance and/or not easily accessible because it is blocked by an appliance shall not be counted as a separate outlet. In kitchens with less than six (6) linear feet of counter top, two (2) of the three (3) required outlets may be within the counter top space. All new receptacles added over counters must be ground fault protected. d. Every hall, water closet compartment, bathroom, laundry room or furnace room shall contain at least one (1) ceiling-mounted or wall-mounted fixture outlet. For purposes of this section a laundry closet shall not be considered a laundry room. e. In bathrooms, the lighting outlet shall be controlled by a wall switch or fixture pull chain. In addition to the lighting outlet in every bathroom and laundry room, there shall be provided at least one (1) receptacle outlet. Any new or replacement bathroom receptacle outlet shall have ground fault circuit interrupter protection. f. All outlets, switches, wiring and light fixtures shall be safe and operable. No extension cords shall be spliced or used as fixed wiring of a dwelling. Electrical odor, flickering lights, visibly frayed wiring, broken switch plates or failure of circuit-tester check shall be evidence of an unsafe electrical system. g. Every exterior entrance shall be lighted at grade level and controlled with a wall mounted interior switch. (d) Exterior and interior. (1) Foundation. The building foundation system shall be maintained in a safe manner and capable of supporting the load which normal use may cause to be placed thereon. Beneath the dwelling, there must be firm, reasonably dry ground free of rubbish and debris, ("reasonably dry" means no mud, standing water, running water or evidence of same). The area beneath the dwelling must also be reasonably free of debris and rubbish. Manufactured homes shall be set up and secured as required by the North Carolina State Building Code's Regulations for Manufactured/Mobile Homes. (2) Exterior walls. a. Every exterior wall shall be reasonably weathertight, (free of holes, breaks, loose or rotting boards or timbers, and any other conditions which might admit rain, dampness, vermin or air to the wall cavity or to the occupied spaces of the building). All siding material shall be kept in repair. "Kept in repair" includes maintenance of painted surfaces areas where the protective paint surface no longer protects wood or other organic building materials from weather damage, repair or cracks or holes exceeding one-quarter (¼) inch in width and replacement of wood or other organic components that show visual signs of rot, are soft to the touch or otherwise show evidence of rotting. b. Existing skirting for manufactured shall be maintained free from broken or missing sections, pieces or cross-members which compromise the insulation characteristics of the skirting. Skirting shall be securely attached and sized from the ground to the lower outside perimeter of the structure. c. Replacement or new skirting for manufactured shall be constructed of materials intended for exterior use and properly sized and mounted to prevent free access to the crawl space of the dwelling. Adequate means to gain access to the dwelling crawl space, to heating or other mechanical equipment, via inside or outside, shall be furnished. d. The space between the ground and the first floor of every dwelling other than manufactured dwellings shall be enclosed with a masonry curtain wall which shall be reasonably weathertight and rodent proof. (3) Roofs. a. Roofs shall be structurally sound, and maintained in a safe manner and have no defects which might admit rain or cause dampness in the walls or interior portion of the dwelling. The following may constitute evidence of defects: 1. Missing shingles; 2. Flashing(s) missing; 3. Roof deflection deeper than one-sixth (⅙) of the depth of the rafter and/or rafters cracked; 4. Damage to ceilings (ceiling plaster loose or falling, brown spots, etc.), sheet rock hanging, etc. in rooms below roof; or 5. Fire damage. b. No more than three (3) layers of roofing materials (shingles, shakes, roofing) shall be permitted. (4) Attics. All attics shall be ventilated and shall be provided with a minimum fourteen (14) inch by twenty-four (24) inch access opening from the interior of the structure. (5) Insulation. Insulation rated at least R-19 (or a minimum thickness of four (4) inches) and consisting of rock wool (glass), fiberglass or other material exhibiting fire-resistance and insulation capabilities equal to (or greater than) rock wool or fiberglass shall be required in the accessible ceilings or attics of the highest story containing habitable rooms in dwellings. (6) Means of egress (exits). In multi-family houses having two (2) or more dwelling units above the first floor, every dwelling unit above the first floor shall have access to at least two (2) exit ways. One (1) common exit is permitted provided that all of the following are met: Exception: a. Maximum distance of travel to reach the exit or stairs from the entrance door to any dwelling unit shall not exceed thirty (30) feet. b. Maximum number of dwelling units served by the exit shall not exceed four (4) per floor. c. Maximum gross area of the dwelling units shall not exceed three thousand five hundred (3,500) square feet per floor. d. Maximum building height shall be one (1) floor above the level of exit discharge. (7) Stairs, porches and appurtenances. a. Every inside and outside stair, porch and any appurtenances thereto shall be safe to use and capable of supporting the load that normal use may cause to be placed thereon and shall be kept in sound condition and good repair. Stairs and steps shall be free of holes, grooves and/or cracks large enough to constitute accidental hazards. Risers shall be reasonably uniform in height. Stair coverings shall be securely mounted and shall not interfere with safe use of the stairs. b. Every exit more than thirty-six (36) inches above the finished grade shall be equipped with a porch with dimensions at least as wide and deep as the width of the exit doorway at the exit. (8) Protective railings. Every porch, terrace or entrance platform thirty-six (36) inches above adjacent finish grade shall be equipped with railings or guards not less that thirty (30) inches high. Handrails, continuous on all open sides of stairs exceeding four (4) risers, leading to a platform, porch or terrace, shall be installed at least thirty (30) inches high. Interior stairs exceeding four (4) risers, open on both sides, including basement stairs, shall have a continuous handrail on one (1) side and railing on open portions of the other side. Stairs open on one (1) side exceeding four (4) risers shall have a continuous handrail and railing on the open side. Stairs exceeding four (4) risers, enclosed on both sides, shall have a minimum on one (1) continuous handrail. When exterior stairwell step flight has a total rise of thirty (30) inches or more, a continuous, durable handrail must be maintained. Handrails or protective railings shall be capable of bearing normally imposed loads and be maintained in good and safe condition. Adjacent horizontal or vertical rails or rail members shall be spaced no more than four (4) inches apart for protection of children when such protective railing is along a platform or stair thirty-six (36) inches or more in height. (9) Windows and window assemblies. a. Each window shall be weathertight, watertight and rodent proof, and shall be kept in good repair. If daylight can be seen around the inside or outside perimeter of the window casing, that window does not meet this standard. Every openable window shall be equipped with an effective locking mechanism or other mechanism that functions as a lock. b. Each window sash shall be fully supplied with glass windowpanes or an approved substitute which are without open cracks or holes. Wood, cardboard or polyethylene or other plastic film are not approved substitutes. A windowpane with a crack or hole must be replaced, provided, however, holes less than one-quarter (¼) inch in surface diameter may be sealed with a clear silicone seal. A broken window (pieces missing or exposed glass edge) must be replaced. c. Each window sash shall be properly fitted and weathertight within the window frame. If daylight can be seen around the inside or outside perimeter of the window sash, that window does not meet this standard. d. Each window required for ventilation for habitable rooms shall be capable of being easily opened or closed and secured in position by window hardware. (10) Exterior doors. a. Every exterior door, basement or cellar door and hatchway shall be substantially weathertight, watertight, and rodent proof, and shall be kept in sound working condition and good repair. "Good repair" includes no delamination or splitting of wood doors. b. Every exterior door to a dwelling shall be provided with properly installed hardware that is maintained to insure reasonable ease of operation to open, close or secure in an open or closed position, as intended by the manufacturer of the door and the attached hardware. Properly installed hardware shall consist of knob, bib and operating lock with sufficient strength to prevent unauthorized entry short of disassembly, force or use of a key or pick. All exterior doors shall be capable of being locked from the inside and outside in a manner that will provide for the safety and security of the occupant(s). (10) Exterior door frames. a. Exterior doorframes shall be properly maintained and shall be equipped with weather-stripping and thresholds as required to be substantially weathertight, watertight, and rodent and insect restrictive when the door is in a closed position. If daylight can be seen from inside around the inner perimeter of an exterior doorframe, that door frame does not meet this standard. b. Exterior door jambs, stops, headers and moldings shall be securely attached to the dwelling, maintained in good condition without splitting or deterioration that would minimize the strength and security of the door in a closed position. If daylight can be seen from inside around the outer perimeter of an exterior doorframe, that door frame does not meet this standard. (12) Screens. In order to provide for safe ventilation and to provide for the safety of children, dwelling units which do not have central air-conditioning systems shall have fitted screens in good repair for all operable windows in rooms where the floor level is eight (8) or more feet above finished grade below the window. On floors below eight (8) feet above finished grade, screens are required on operable windows required by section 11-10(b) of this Code. "Good repair" means screens providing a continuous barrier to insects constructed of undamaged metal or plastic screen with at least sixteen (16) by sixteen (16) meshes to the inch or fourteen (14) by eighteen (18) meshes to the inch. Screens shall not be permanently affixed to the window frame or sash by nails, staples or screws. (13) Protective treatment. All exterior wood surfaces (other than decay-resistant woods, such as cedar, redwood, cypress or pressure-treated lumber) shall be protected from the elements and decay by painting or other protective covering or treatment. Minimal chipping or peeling of surfaces not directly exposed to the elements and not reasonably expected to contribute to decay of wood is not required to be treated. All siding shall be weather-resistant and water tight. All masonry joints shall be sufficiently tuckpointed to insure water and airtightness. "Sufficiently tuckpointed" means that mortar shall not be removable by finger pressure. (14) Outbuildings. Garages, storage buildings and all other accessory structures shall be structurally sound. When the condition of plumbing, heating, structural or electrical facilities present an imminent danger to occupants, or to the public, if such outbuilding is accessible to the public, those facilities shall be made safe in a manner consistent with this Code. (15) Interior floors, walls and ceilings. Every floor, interior wall and ceiling shall be substantially vermin-proof, shall be kept in sound condition and good repair and shall be safe to use and capable of supporting the load which normal use may cause to be placed thereon. Interior finish shall be free of excessive holes and cracks. No cardboard or other highly combustible or improper wall finish or ceiling finish shall be allowed. All floors shall be level enough so as not to present a tripping hazard. Every bathroom floor surface and kitchen floor surface shall be constructed and maintained so as to be reasonably impervious to water and so as to permit such floor to be readily kept in a clean and sanitary condition. Every tub or shower area shall have a wall surface constructed and maintained so as to be substantially impervious to water. (16) Structural supports. Every structural element of the dwelling shall be maintained in a structurally sound condition and show no evidence of deterioration which would render it incapable of carrying normal loads. Termites, termite damage, fire damage, absence of footings or cracked or split wood structural supports are examples of evidence of deterioration. When additional direct support is required, piers shall be used under girders, at walls or other primary support points. Stiff knees shall not be used for girders, at walls or at other primary support points, but may be used for indirect support only. (17) Firestopping and draftstopping. Firestopping shall be maintained to cut off all concealed draft openings both horizontal and vertical and to form a fire barrier between floors and between the upper floor and the roof space. Draftstopping shall be maintained to cut off all concealed draft openings in floor/ceiling assemblies and in attics. (18) Interior door hardware. Every interior door shall be provided with proper hardware, securely attached and maintained in good condition. Hasp lock assemblies are not permitted on any side of the door of habitable rooms. (19) Bathroom access. Bathroom access shall be provided in a manner that does not require an occupant to leave the dwelling to gain access. Privacy of bathrooms shall be afforded by doors complete with privacy hardware intended by the manufacturer for that purpose. (20) Bedroom access. Privacy of bedrooms shall be afforded by doors complete with privacy hardware intended by the manufacturer for that purpose. (21) Water closet, lavatory and bath facilities for boardinghouses. At least one (1) flush water closet, lavatory basin, and bathtub or shower, properly connected to a water and sewer system and in good working condition, shall be supplied for each four (4) rooms within a rooming house wherever such facilities are shared. All such facilities shall be located on the floor they serve within the dwelling so as to be private and reasonably accessible from a common hall or passageway to all persons sharing such facilities. (e) Space requirements. (1) Required space. Every dwelling shall contain at least one hundred fifty (150) square feet of floor space for the first occupant thereof and at least one hundred (100) additional square feet of floor area per additional occupant. The floor area shall be calculated on the basis of the total area of all habitable rooms. Provided, however, the requirement of this section shall not be applicable to hotels, motels, and other transient dwellings. (2) Required space in sleeping rooms. In every dwelling, every room occupied for sleeping purposes by one (1) occupant shall contain at least seventy (70) square feet of floor space, and every room occupied for sleeping purposes by more than one (1) occupant shall contain at least fifty (50) square feet of floor space for each occupant thereof. (3) Ceiling height. Habitable rooms other than kitchens, storage rooms and laundry rooms shall have a ceiling height of not less than seven (7) feet six (6) inches. Hallways, corridors, bathrooms, water closet rooms and kitchens shall have a ceiling height of not less than seven (7) feet six (6) inches measured to the lowest projection from the ceiling. If any room in a dwelling has a sloping ceiling, the prescribed ceiling height of the room is required in only one-half (½) the room area. No portion of the room measuring less than five (5) feet from the finished floor to the finished ceiling shall be included in any computation of the minimum floor area. (4) Occupancy below grade. No basement or cellar space shall be used as a habitable room or dwelling unless: a. The floor and walls are resistant to leakage of underground and surface runoff water, and show no evidence of recent water leakage or accumulation; and b. The total window area (or window well area) is equal to at least the minimum window and ventilation areas described in section 11-10(b) of this Code, except that in non-sleeping rooms, mechanical ventilation and electric light may be used in place of window ventilation and light; and c. An easily accessible means of fire escape in addition to the basement or cellar stair is provided. Windows which are easily accessible and of sufficient size to accommodate occupants escaping a fire are acceptable. (f) Sanitation requirements. Every owner of a dwelling shall provide a clean, safe and sanitary dwelling at the time of tenant occupancy or reoccupancy and shall be responsible for maintaining in a clean, safe and sanitary condition outbuildings and appurtenances to the extent that such outbuildings and appurtenances are regulated by this code. Tenants shall be responsible for maintaining a clean and sanitary structure in regard to cleanliness, accumulation of garbage and/or rubbish inside the dwelling and any outside areas associated with the dwelling. (g) Extermination. Every owner of a multifamily dwelling or a boardinghouse dwelling shall be responsible for the extermination of any insects, rodents, or other pests within the dwelling or premises. If the owner fails to provide such extermination services and evidence of insect, rodent or other pest infestation is present, extermination shall be ordered by a code enforcement official. Such extermination shall be conducted by a licensed exterminator. Monthly extermination treatment is the maximum that an owner shall be required to provide. Every occupant of a dwelling containing a single unit shall be responsible for the extermination of any insects, rodents, or other pests therein or on the premises. (h) Violation(s) of state building code regulations for existing dwellings. A dwelling that is not in compliance with Volume I, Chapter 34 of the N.C. State Building Code or Volume IX of the N.C. State Building Code shall be considered unfit and ineligible for a housing certificate under this Code unless the owner has been granted a building permit for work that would bring the structure into compliance with either Volume I, Chapter 34 or Volume IX of the North Carolina State Building Code. Expiration of the permit without completion of such work shall result in revocation of the housing certificate issued for such dwelling. (i) [Compliance with building codes required for ordered repairs.] All repairs made as a result of orders issued under this code shall be completed in compliance with the North Carolina State Building Code and in accordance with construction and repair methods generally accepted in the industry. All materials used in a specific application shall be approved for use in that application and shall be compatible in appearance with surrounding materials.
(Ord. No. 0-98-20, § 1, 3-9-98; Ord. No. 0-01-57, § 1, 7-23-01; Ord. No. 0-06-70, § 1, 7-10-06; Ord. No. O-2009-34, § 1, 4-27-09)
Ask a question about Rocky Mount law
Corpus searches the Rocky Mount sections it holds and shows the ones that match, with their citations. Free, no sign-in.
