§ 21-29.2 — Interceptor installation and maintenance
Code of Ordinances of the City of Rocky Mount, North Carolina (Codified through Ordinance No. O-2025-71, enacted November 10, 2025. (Supp. No. 90)) · Rocky Mount City Code § 21-29.2
Corpus is an independent public-information project, not the official City of Rocky Mount website. Stable reference: corpuslaw.us/code/b8f29e7b-546f-4567-8666-dd1d09bac90b
Sec. 21-29.2. - Interceptor installation and maintenance.
(a) Grease interceptors or traps shall be installed and maintained at the user's expense when a user operates a food service establishment. Grease interceptors may be required in non-cooking or cold dairy and frozen foodstuffs establishments and other industrial or commercial establishments when the establishment generates wastewater containing fat or grease in excess of section 21-30.1 as provided in the City of Rocky Mount's Sewer Use Ordinance. The director of water resources is authorized to determine when an interceptor or trap is necessary to prevent contribution or accumulation of grease to the sanitary sewer collection and treatment system. Upon notification by the director of water resources or his or her designee that the user is subject to the terms of an enforcement action, as stipulated in the FOG enforcement response plan, said user shall not allow wastewater discharge concentration from subject grease interceptor to exceed the action level as prescribed in the sewer use ordinance, expressed as hexane extractable material. All grease interceptors shall be of a type, design, and capacity approved by the director of water resources and shall be readily and easily accessible for maintenance and repair, including cleaning and city inspection. All grease interceptors shall be serviced and emptied of accumulated waste content as required to maintain the minimum design capability or effective volume of the grease interceptor, but not less often than every sixty (60) calendar days or as permitted in a valid program modification. Users who are required to pass wastewater through a grease interceptor shall adhere to the following provisions: (1) Grease interceptor sizing formula to obtain minimum design capability for new installations, amendments, or modifications to existing installations shall be as follows: GI = SC x FF x RT x SF Whereby: GI = interceptor volume in gallons SC = Seating capacity RT = Retention time (0.4 hour) SF = 9.375 Storage factor (dimensionless) FF = Flow factor (gallons/seat/hour) Deep frying and dishwasher .....FF = 3.0 No deep frying and dishwasher .....FF = 2.5 Deep frying and disposable serving ware .....FF = 2.5 No deep frying, reusable serving ware, and no dishwasher .....FF = 2.0 No deep frying and disposable serving ware .....FF = 1.5 No cooking of any type and disposable serving ware .....FF = 0.5 (2) Provide for a minimum hydraulic retention time of twenty-four (24) minutes (0.40 hour) at actual peak flow between the influent and effluent baffles, with twenty-five (25) percent of the total volume of the grease interceptor being allowed for any food-derived solids to settle or accumulate and floatable grease derived materials to rise and accumulate, identified hereafter as a solids blanket and grease cap respectively. (3) Remove any accumulated grease cap and solids blanket as needed, but at intervals of not longer than sixty (60) calendar days at the user's expense, or in accordance with a valid program modification or other requirements established by the director of water resources. Grease interceptors shall be kept free of inorganic solid materials, such as grit, rocks, gravel, sand, eating utensils, cigarettes, shells, towels, rags, etc., which could settle into this solids blanket and thereby reduce the effective volume and detention time of the grease interceptor. (4) Operate and maintain the grease interceptor to achieve and consistently maintain any applicable grease action level. "Consistent" shall mean any wastewater sample taken from such grease interceptor must meet the terms of numerical limit attainment described in subsection 21-29.2(a). (5) If a user documents that conditions exist ("space constraints") on their establishment site that limit the ability to locate a grease interceptor on the exterior of the establishment, the user may request an interior location for the interceptor. Such request shall contain the following information: i. Location of city sewer main and easement in relation to available exterior space outside building. ii. Existing plumbing layout at or in a site. iii. A statement of understanding, signed by the user or authorized agent, acknowledging and accepting conditions the director of water resources may place on permitting an identified interior location. Conditions may include requirements to use alternative mechanisms, devices, procedures, or operations relative to an interior location. iv. Such other information as may be required by the director of water resources. (6) If the user performs on-site grease interceptor treatment pursuant to a modification granted under subsection 21-29.5(c)(2), the user shall: i. Prior to commencement of onsite treatment obtain written approval by and from the director of water resources of all processes utilized in said onsite treatment. ii. If any pumped wastes or other materials removed from the grease interceptor are treated in any fashion on-site and reintroduced back into the grease interceptor as an activity of and after such on-site treatment, the user shall meet the criteria contained in subsection 21-29.2(6)(iii) below. iii. Attain and adhere to the criteria listed below: a. After thirty (30) minutes of settling time, not more than 3.0 milliliter per liter of settleable solids, as measured in a one (1) liter Imhoff cone shall be allowed. b. Within and not more than twenty-four (24) hours after onsite grease interceptor servicing, not more than two (2) (inches) of settable solids and/or grease shall be allowed to have accumulated therein as a result of said operations. c. Service vehicles and equipment used in onsite grease interceptor servicing shall be registered with the North Carolina Division of Waste Management. d. When service is being provided, grease interceptor service vehicles and equipment shall have onboard, at all times, a certificate of approval for the operations and methods used, issued by the director of water resources. e. Any tanks, tankage, or vessel(s) associated with a modification shall be empty upon arrival at the initial FSE user site. (7) The use of biological or other additives as a grease degradation or conditioning agent is permissible only upon prior written approval of the director of water resources. Any user using biological or other additives shall maintain the trap or interceptor in such a manner that attainment of any grease wastewater, action level, solids blanket or grease cap criteria, goal or directive, as measured from the grease interceptor outlet or interior, is consistently achieved. (8) The director of water resources may make determinations of grease interceptor adequacy, need, design, appropriateness, application, location, modification(s), and conditional usage based on review of all relevant information regarding grease interceptor performance, facility site and building plan review by all regulatory reviewing agencies and may require repairs to, or modification or replacement of grease interceptors.
(Ord. No. O-2013-71, § 1(Exh. A), 6-24-13)
Ask a question about Rocky Mount law
Corpus searches the Rocky Mount sections it holds and shows the ones that match, with their citations. Free, no sign-in.