§ 601 — Dimensional standards
Code of Ordinances of the City of Rocky Mount, North Carolina (Codified through Ordinance No. O-2025-71, enacted November 10, 2025. (Supp. No. 90)) · Rocky Mount City Code § 601
Corpus is an independent public-information project, not the official City of Rocky Mount website. Stable reference: corpuslaw.us/code/a1b0fb3a-25c5-4c70-b147-bfadd3b0f996
Sec. 601. - Dimensional standards.
The table below contains the dimensional standards for the various zoning districts applicable to new structures and/or uses. Table 6-1. Lot & Yard Dimensional Standards Minimum Lot Size | Minimum Yard Regulations District | Area (in sq. ft., unless otherwise specified) | Per Dwelling Unit (in square feet) | Front Yard Setback (in feet) (see note 7) | Side Yard Width (in feet) | Rear Yard Depth (in feet) | Max. Height of Structure (in feet) (see note 6) | Lot Width at MBL (in feet) | Lot Frontage (in feet) A-1 Agricultural District Single-family | 20,000 | 20,000 | 50 | 15 | 40 | 35 | 100 | 35 R-15 Very Low Density Residential District Single-family | 15,000 | 15,000 | 40 | 15 | 40 | 35 | 100 | 35 R-10 Low Density Residential District Single-family | 10,000 | 10,000 | 30 | 12 | 30 | 35 | 75 | 35 R-8 Manufactured Residential District Single-family | 8,000 | 8,000 | 25 | 9 | 20 | 35 | 90 | 35 R-6 Single-family Residential District Single-family | 6,000 | 6,000 | 25 | 10 | 20 | 35 | 60 | 35 R-6MFA Medium-High Density Multifamily Residential District Single-family | 6,000 | 6,000 | 25 | 10 | 20 | 35 | 60 | 35 Two-family | 7,000 | 3,500 | 25 | 10 | 20 | 35 | 60 | 35 Multifamily (Condos/Townhomes See Section 712.29 of the LDC) | 7,000 for the first 2 dwelling units and 1,800 for each add'l dwelling unit | 3,500/1,800 | 25 | 8 | 20 | 60 | 60 | 20 MHP Manufactured Home Park Residential District (See Section 712, 31 | N/A | N/A | N/A | N/A | N/A | N/A | N/A PDR Planned Density Residential District (See Section 713 of this LDC) | 200 acres O-I Office and Institutional Residential use (same as R-6) | Single-family Office Institutional Use | 0 | 0 | 25 | 8 | 20 | 60 | 0 | 25 Multifamily | 7,000 for the first 2 dwelling units and 2,500 for each add'l dwelling unit | 3,500/ 2,500 | 25 | 8 | 20 | 60 | 60 | 20 MA- Med. Arts | 10,000 | 30 | 15 | 20 | 75 | 35 B-1 Commercial Neighborhood | 50 | 20 | 20 | 0 | 0 B-2 Commercial Corridor | 50 | 20 | 20 | 0 | 0 B-3 Commercial Regional | 50 | 20 | 20 | 0 | 0 O-I(2) Office mixed use district (combination of business, office and residential) 2 acres | 30 | 15 | 20 | 60 | 0 | 0 B-4 CBD Nonresidential | 0 | 0 | 0 | 0 | 0 Residential (SF) | 6,000 | 6,000 | 25 | 10 | 20 | 35 | 60 | 35 B-5 Commercial Services | 25 | 10 | 10 | 0 | 0 I-1- Industrial Light | 75 | 50 | 50 | 0 | 0 I-2- Industrial Heavy | 25 | 10 | 10 | 0 | 0 I-P- Industrial Park | 50 acres | 50 | 50 | 56 1. In the I-1 district above, the space created by the front yard setback line shall remain unobstructed except for landscaping. The rear yard space may be used for off-street parking; provide, however, that in the event the rear and/or side line faces a residential district, the space created by the rear and/or side yard setback shall remain clear and unobstructed, unless a planting screen is maintained along the property line of such type and height as to obscure from view any automobile parked on the lot. 2. In the I-P district above, a setback of two hundred (200) feet shall be maintained from all exterior boundaries of the industrial park. This does not refer to interior lots within the park. 3. Special use requirements take precedence. Area, yard and height requirements as specified in the issuance of a special use permit shall take precedence over area, yard and height requirements as set forth in chapter 6 herein. 4. In all areas within one thousand (1,000) feet of any public aircraft landing field, a structure exceeding thirty-five (35) feet shall be permitted only upon a finding by the board of adjustment after a public hearing that is does not constitute a menace to safety. 5. Chimneys, belfries, conveyors, cupolas, derricks, domes, gasholders, fire towers, flagpoles, flues, monuments, smokestacks, transmission towers, ventilators, water towers, tanks, radio towers, poles, antennae, wires, wireless communications towers and similar structures may be erected to any height in accordance with existing or hereafter adopted LDC of the city, provided the foundation guy wires, support or Anchorage of the structure is constructed in an acceptable method and approved by the inspection services administrator, or authorized agents. In locations where Federal Aviation Agency (FAA) regulations are applicable, such structures shall comply with FAA requirements. The provisions of this table of area, yard and height requirements of this LDC do not apply to the enumerated items. 6. Within the central city area, the height limitation for buildings within the office and institutional zoning district may be constructed to a maximum height of eighty-five (85) feet. 7. Corner lots. Relative to a corner lot, a side yard setback consisting of one-half (½) of the distance of the required front yard setback up to a maximum of twenty (20) feet shall be maintained between the prospective building and the side street. This requirement shall not be applied so as to reduce the building width of a residentially zoned corner lot of record at the time of passage of this LDC to less than thirty (30) feet, nor to prohibit the erection of any accessory building where this requirement cannot reasonably be complied with as determined by the board of adjustment. 8. Relative only to any buildings being developed under the regulations for attached dwelling units for rental or individual ownership, the side yard or separation between buildings for end dwelling units shall be at least fifteen (15) feet. 9. Within nonresidential districts, the minimum lot area shall be seven thousand (7,000) square feet for the first two (2) dwelling units and two thousand five hundred (2,500) for each additional dwelling unit where residential land uses are developed.
(Ord. No. O-05-34b, § 1(Att. A), 5-9-05; Ord. No. O-06-19, §§ 2a—2c, 3a, 3b, 3-13-06; Ord. No. O-09-2, § 4, 1-12-09; Ord. No. O-21-68, § 5, 8-9-21)
Ask a question about Rocky Mount law
Corpus searches the Rocky Mount sections it holds and shows the ones that match, with their citations. Free, no sign-in.
