Sec. 6-31. - Standards of fitness.
(a) Space and use standard. (1) Room size. Dwellings shall contain not less than one sleeping room, one bath and a kitchen or kitchen facility. The bathroom shall be of such size and arrangement of fixtures so that it shall provide for comfortable use of each fixture. (2) Contents of dwelling unit. Every dwelling unit shall contain the following: a. A bathroom that affords privacy and contains a toilet, lavatory and either a tub or shower; b. At least 70 square feet of floor area in each habitable room. (3) Habitable rooms. Every habitable room in every dwelling unit shall be at least seven feet wide with at least one-half of the floor area having a ceiling height of at least seven feet. That portion of any room where the ceiling height is less than five feet shall not be considered as a part of the floor area. Refer to subsection (a)(2)c of this section. (b) Kitchen and kitchen facilities. Every dwelling unit shall contain a room or space for the preparation and cooking of food which shall include space and connections for a stove or other cooking facilities, space for dry food storage and space for refrigerated food storage and a kitchen sink. Each kitchen shall have a cabinet, or a base cabinet combined with wall cabinets or other enclosed area, which provides the following: (1) A minimum of 30 square feet of enclosed shelf space; (2) Drawer space containing a minimum of five square feet; (3) Countertop area with a minimum of six square feet in area and covered with a waterproof nonabsorbent material safe for contact with food. Areas occupied by sinks and countertop cooking units shall not be included in the minimum required countertop area. (4) The use of gasoline stoves or other similar fuel-burning appliances using highly flammable liquids, and the use of portable kerosene stoves or other similar fuel-burning portable appliances for cooking, is prohibited. Hoods and ducts over kitchen ranges shall be cleaned with sufficient frequency so as to remove grease or other flammable materials that might collect therein. (c) Basement occupancies. No room in any basement shall be occupied as a habitable room, bathroom or toilet room unless: (1) Habitable space, hallways and portions of basements containing these spaces shall have a ceiling height of not less than seven feet. Bathrooms, toilet rooms and laundry rooms shall have a ceiling height of not less than six feet eight inches. Beams, girders, ducts and other obstructions in habitable space shall be permitted to project within six feet four inches of the finished floor; (2) The floor and walls, if in contact with the earth, are waterproofed and dampproofed in accordance with a method approved by the administrator. Such waterproofing and dampproofing shall be between the floor or wall finish and the ground. The administrator may use discretionary powers insofar as subsections (c)(1) and (2) of this section. (d) Passing through bathrooms. Each dwelling unit shall be provided with a means of circulation giving access to all rooms without passing through a bathroom; but any passage through a bathroom existing at the time of the effective date of the ordinance from which this article is derived may be continued. (e) Doors. (1) Doors shall be provided at all doorways leading to bedrooms, bathrooms and all rooms adjoining a public area. (2) Type of lock or latch. All interior egress doors shall be readily operable from the side from which egress is to be made without the use of a key or special knowledge or effort. (f) Prohibited uses. Kitchens and uninhabitable or public spaces shall not be used for sleeping purposes. No cellar space shall be used as a habitable space. (g) Entrances and exits. (1) All entrances and exits must meet the standards set forth in the state building code which is in effect at the time of construction. (2) Type of lock or latch. All exterior egress doors shall be readily operable from the side from which egress is to be made without the use of a key or special knowledge or effort. (3) Doors providing entrance and exit for any dwelling unit shall have locking devices capable of being operated from the inside and outside of the dwelling. Barrel bolts and hasps with padlocks are not adequate for primary doors. This requirement shall not apply to screen doors, storm doors or louver doors. (4) Safe, continuous and unobstructed exits shall be provided from the interior of the building to the exterior at street or grade level. (5) Platforms and steps shall be provided, where appropriate, to serve exits and shall be maintained in a safe condition. (h) Light and ventilation standards. (1) Every habitable room in a dwelling or dwelling unit shall contain a window opening directly to the outside air, and the total glass area of such window shall not be less than eight percent of the floor area of such room, provided that the administrator may approve such other arrangement as will adequately light and ventilate the room where provision for operable windows is not feasible. All window sashes shall be glazed and provided with suitable hardware, and shall be made to open freely to the extent of not less than four percent of the floor area of such room. (2) When a window cannot be provided to open directly to the outside air, a ventilating system may be substituted for the required window area. A blind kitchen, bathroom or toilet room shall be provided with artificial light and mechanical ventilation. However, existing ventilating systems in bathrooms and toilet rooms which are functioning adequately may be permitted to remain. (3) All operable windows shall be adequately screened or equipped with storm windows from the period of May 1 to November 1. Screens shall not be permanently fixed to the window frame or sash. All operable exterior doors shall have either a screen door or a storm door, equipped with a self-closing device, from the period of May 1 to November 1. This requirement shall not apply to dwelling units containing a heating and air conditioning system providing the dwelling unit with year-round mechanical ventilation, including permanently installed systems which provide such mechanical ventilation for one or more rooms. This requirement shall apply to dwelling units equipped with window air conditioning units which are not permanently installed. (4) Window frames and glass shall be reasonably weathertight, with no cracked or broken glass. If, in the opinion of the administrator, certain cracked glass does not present a danger or hazard, a waiver of this provision may be granted. (5) Operable window area in each toilet room and bathroom shall be at least 1 ½ square feet, unless served by other approved ventilation. (6) Every sleeping room built prior to 1993, unless it has two exits or one exit direct to the outside, shall have at least one operable window or door that can be opened without the use of tools, including burglar bars, to provide a clear opening not less than 22 inches in height and 20 inches in width and four square feet in area, with the bottom of the opening not more than 44 inches above the floor. (i) Lighting of halls and stairs. Every common hallway and stairway in every multifamily dwelling shall be adequately lighted at all times with fixtures sufficient to provide at least one footcandle of light at the floor or stair tread level at all times. Single-family dwellings may be supplied with conveniently located light switches controlling the lighting system which provides the illumination required herein and which may be turned on when needed. (j) Heating. Every dwelling and dwelling unit shall be provided with a heating unit which is properly designed, installed and balanced or adjusted, maintained in good and safe condition, and which is capable of safely and adequately heating all habitable rooms and bathrooms located therein to a temperature of at least 68 degrees Fahrenheit at a distance of three feet above the floor level when the outside temperature is between 20 degrees Fahrenheit and 68 degrees Fahrenheit. All rooms may vary in temperature by as much as ten degrees Fahrenheit. Either central or space heating units designed for continuous use may be used. Portable or temporary space heaters are strictly prohibited as a primary source of heat, but may be used to supplement heating. (1) Central heating units. Every central heating unit shall: a. Have every duct, pipe or tube free of leaks and functioning properly to provide an adequate amount of heat or hot water to the intended place of delivery; b. Be provided with proper seals between sections of hot air furnaces to prevent the escape of noxious fumes and gases into heat ducts; c. Be properly connected to an electric circuit of adequate ampacity in an approved manner, if electrical power is required; d. Be provided with all required automatic or safety devices, and be installed and operated in the manner required by the town's laws, ordinances and regulations; e. All liquid fuel used to operate any central heating unit shall be stored in accordance with the state building codes; and f. All gas and oil heating equipment installed on the premises shall be listed by a testing laboratory, and shall be installed in accordance with the provisions of the state building codes. (2) Space heating units. Every space heating unit shall: a. Not use gasoline or other similar highly flammable liquid fuel; b. Not be of a portable type using solid, liquid or gaseous fuel; c. Be properly connected according to the manufacturer's instructions on installation; d. Be so located or protected as to prevent any overheating of adjacent combustible material; e. If employing electricity, it shall be connected to a circuit of adequate ampacity in an approved manner; f. Be provided with all required automatic or safety devices; and g. Be installed under permit and be properly operated. (3) A kerosene space heater which has its fuel piped to the heater from a remotely installed bulk tank shall be permissible under this section. Other portable kerosene space heaters are strictly prohibited as a primary source of heat. (4) All unvented gas-fired heating units are strictly prohibited as a primary source of heat. (5) Ornamental gas logs may be installed in a fireplace provided that such installation is in compliance with the state mechanical code. (k) Fireplaces and chimneys. (1) Chimneys shall be tight and safe, and capable of maintaining proper draft for carriage of combustion byproducts to outside air. (2) Chimneys shall be kept clean of soot and other debris. (3) No holes shall be permitted in a flue, except for necessary vent connections and cleanout doors. (4) All existing hanging masonry chimneys shall be removed. (5) Thimbles shall be grouted in tight. (6) Thimbles shall be located high enough to provide proper draft for the heating appliances served thereby. (7) Fireplaces may be used only for supplemental heat and not as the primary heating source for a dwelling. This section does not exclude the use of wood-burning stoves or inserts as the primary heating source for a dwelling. (8) The hearth and the hearth extension shall extend a minimum of 36 inches from the back of the firebox to the end of the hearth extension. The hearth extension shall extend at least 16 inches in front of, and at least eight inches beyond, each side of the fireplace opening. Where the fireplace opening is six square feet or larger, the hearth extension shall extend at least 20 inches in front of, and at least 12 inches beyond, each side of the fireplace opening. (9) No combustible materials shall be permitted within seven inches of the top and seven inches of either side of the fireplace opening. (10) Where the fireplace is closed and converted to other use, there shall be a masonry closure of the face and a proper lining or vent installed in the chimney where the same does not exist. (l) General requirements relating to safety and maintenance. (1) Good repair and safe condition. Every building and all parts thereof used or occupied as a dwelling shall be kept in good repair, in safe condition and fit for human habitation. The roof and walls of all such buildings shall be maintained so as not to leak; and all means of draining water therefrom shall be maintained as to prevent dampness in the walls, ceiling or crawl space or basement. (2) Quality of materials and workmanship. All materials, such as shingles, framing materials, windows and doors, shall be of consistent design and similar quality, fitness and finish and shall meet the standards set forth in the state building code. Plumbing, mechanical, and electrical components shall meet the standards set forth in the state building codes. The quality of workmanship shall be based on standards generally accepted in the construction industry. (m) Structural standards. (1) Foundation. a. Every dwelling unit shall be on firm ground. Foundation drainage shall be provided and maintained so as to prevent standing water. b. Footings shall be structurally sound with adequate bearing. c. All elements of the foundation, including structural members and masonry, shall be structurally sound. d. No piers shall be used for support in which the plumb line from top center falls outside the middle one-third of the base of the pier. (A plumb bob held firmly against the top of the pier and hanging down the sidewall indicates the vertical alignment.) e. No isolated masonry piers exceeding in height ten times the least dimension of the pier shall be permitted. f. A crawl space access hole with a door shall be provided to any under-floorspace in all dwellings. (2) Walls, exterior. a. All exterior surfaces shall be structurally sound, waterproof, weatherproof and vermin-proof. b. All exterior finishes shall be weathertight with no holes, cracks or rotted boards which permit outside air or water to penetrate rooms. c. Windows shall be easily operable, shall have panes without cracks or holes and the sash shall fit properly. d. All structure- or load-bearing walls, exterior or interior, shall not be bowed or out of plumb and shall be structurally sound. e. Studs shall provide sufficient support for sheathing or exterior finish. (3) Roofs. a. Roofing shall be provided to prevent the entrance of moisture and shall be maintained by renewal, repair, waterproofing or other suitable means. b. Gutters and downspouts, if installed, shall be provided to properly collect, conduct and discharge the water from the roof and away from the structure. c. Roofs shall be supported and no rafters shall be rotted, broken, sagging or have improperly supported ends. d. Attics shall have ventilation that allows the movement of air to dissipate excessive heat buildup. Heat buildup, if excessive, can cause deterioration of any structural member or roofing material. e. Sheathing shall not be rotted, loose or sagging excessively. f. Roof covering shall not be loose, nor have holes or leaks. g. Flashing shall be provided at walls and chimneys and shall be installed in accordance with the state building code. (4) Porches. The foundation, floor, ceiling and roof shall be equal to standards as set forth in this section, except: sills and joist need not be level if providing drainage of floors; floors need not be weathertight; floors need not be level if providing for drainage; minimum ceiling height shall be seven feet and attic need not have insulation. Porches, balconies or raised floor surfaces located more than 30 inches above the floor or grade below shall have guardrails not less than 36 inches in height. Such guardrails shall not be rotted, broken or termite damaged. (5) Stairs and steps. a. Stairs and steps shall be free of holes, grooves and cracks large enough to constitute accident hazards. b. Handrails installed prior to 2012 shall have minimum and maximum heights of 30 inches and 38 inches, and handrails installed 2012 and after shall have minimum and maximum heights of 34 inches and 38 inches, respectively, measured vertically from the nose of the treads, shall be provided on at least one side of stairways of four or more risers, and on open sides of stairs with a rise of 30 inches or greater. c. No flight of stairs shall be settled out of its intended position or pulled away from supporting or adjacent members. d. Stairs shall be strongly supported and supports shall not be rotting, sagging or deteriorated. e. Stairs shall be plumb level and treads shall be uniform in width and risers uniform in height, sound and securely fastened to the structure. A slight uniform tilt of the treads to aid in the runoff of water is permissible for exterior steps. f. Every stairway, including inside stairs and rails, porches, decks and appurtenances thereto, shall be kept in sound condition and good repair. g. Platforms and steps shall be provided to serve exits and shall be maintained in a safe condition. (6) Ceilings. a. Joists and supporting members shall provide sufficient support for the ceiling. b. No holes or cracks which permit outside air to penetrate rooms shall be permitted. c. There shall be no loose plaster, boards, sheetrock, or ceiling finish. Any materials used in the repair of the ceiling shall be of a material that is similar in texture and appearance to the original material. This provision does not prohibit the replacement of the entire ceiling, provided that the material used is contiguous over the entire ceiling area within the affected room. d. Ceilings shall be maintained free of holes, cracks or loose or deteriorated materials. e. All ceilings shall be kept clean and free of any flaking, loose or peeling paint and paper. f. A minimum clear opening (attic access hole) into each attic space of 20 inches by 30 inches shall be provided to allow for access, inspection and repair. In cases where meeting this requirement would necessitate major alterations to the structure, or would produce harmful accumulations of heat or moisture that cannot be removed by ventilation, the administrator may grant a waiver. g. Every dwelling unit constructed prior to 2009 shall have a minimum of R-30 insulation in the attic area and every dwelling unit constructed in 2009 and after shall have a minimum of R-38 insulation in the attic area. (7) Walls, interior. a. Interior finish shall be free of holes and excessive cracks which: 1. Permit outside air or moisture to penetrate rooms; or 2. Contain loose or flaking materials. b. All walls, woodwork, doors and windows shall be kept clean and free of any flaking, loose or peeling paint. c. There shall be no loose plaster, boards, or other loose wall materials. d. Cardboard, newspaper or other highly combustible or improper wall finish is prohibited. e. Studs shall provide sufficient support for interior walls. f. Doors must fit the opening in which they are hung and be equipped with hardware that allows for their opening and closing. (8) Floors. a. Broken, overloaded, excessively decayed or sagging structural floor members are prohibited. b. Structural floor members shall be supported on foundation walls and piers that are not deteriorated and perform the function for which they were intended. c. Floor joists shall be supported on structural-bearing members and shall not be made structurally unsound by deterioration. d. Flooring shall be reasonably smooth, not rotten or worn through, and without holes or excessive cracks which permit outside air to penetrate rooms. e. Flooring shall not be loose. f. Split, splintered or badly worn floorboards shall be repaired or replaced. g. Floors in contact with soil shall be paved either with concrete, not less than three inches thick, or with other masonry not less than four inches thick, which shall be sealed tightly to the foundation walls. h. All bathroom, laundry and kitchen floors shall be constructed and maintained so as to be impervious to water by covering with a waterproof nonabsorbent material. Examples of this type of material include asphalt tile, ceramic tile, linoleum tile or sheet, rubber tile, terrazzo, vinyl tile, vinyl plastic tile or sheet, finished wood, parquet, masonry, and polyurethane. Certain absorbent materials covered with a waterproof finish shall also be permitted. Porch and deck-type enamel paints shall be prohibited due to their nondurable nature. The administrator can approve other types of waterproof nonabsorbent materials that meet the criteria of this section. (n) Property maintenance. (1) Structures. Floors, walls, ceilings and fixtures shall be maintained in a clean and sanitary condition. a. Structures shall be maintained free of insects, vermin, and rodent harborage and infestation by generally accepted materials of extermination. b. Every basement window used or intended to be used for ventilation, and every other opening to a basement which might provide an entry for rodents, shall be supplied with a screen or such other device as will effectively prevent their entrance. c. In every dwelling unit, for protection against mosquitoes, flies, and other insects, every door opening directly from a dwelling unit to outdoor space shall have supplied and installed screens and a self-closing device; and every window or other device with openings to outdoor space, used or intended to be used for ventilation, shall likewise be supplied with screens installed as provided for in subsection (h)(3) of this section, unless the dwelling is provided with an air conditioning system. (2) Open areas. a. Surface water and subsurface water shall be appropriately drained from open areas to protect structures and to prevent development of stagnant ponds. b. Fences and all accessory structures, either attached to or detached from the primary structure, shall be maintained in a safe and substantial condition. Accessory structures shall include, but are not limited to, sheds, storage buildings, carports, and garages. c. Yards and courts within the boundaries of the property shall be kept clean and free of physical hazards, yard waste, trash, food waste, debris, litter, or unstacked wood. d. Unmaintained accumulations of dense weeds, grass, vines or briars over 12 inches in height, and within either 100 feet of an abutting public street or 50 feet of a primary residential structure, not including detached accessory structures, shall be prohibited if deemed to constitute a public nuisance by the administrator. In this provision, the term "public nuisance" is defined as conditions that serve as a harborage for rodents, vermin, mosquitoes and other pests and represents a detriment, danger or hazard to the health, safety and welfare of the residents of the town's jurisdiction. Such accumulations of growth shall be cleared and cut to no more than six inches in height. e. Every owner shall provide a site for storage of trash and recycling receptacles in a location away from the curb so that trash and waste will not scatter on the property beyond that site. Occupants shall be responsible for ensuring that all trash and recycling is placed at the site provided. f. Retaining walls or any other wall supporting systems shall not present a physical hazard and shall be structurally safe and supported properly. (o) Electrical standards. (1) Electrical service. a. Every dwelling unit and all public and common areas shall be supplied with adequate electric service, of at least 100 amps, which shall be properly installed and connected to the source of electric power in a manner prescribed by the National Electrical Code. b. No receptacles, ceiling fixtures or other devices shall be permitted to hang loose. c. All switches, fixtures and devices shall be safely operable or else properly sealed off and disconnected. d. Flexible cords shall not be used as a substitute for the fixed wiring; run through holes in walls, ceilings, or floors; run through doorways, windows or similar openings; attached to building surfaces; concealed behind building walls, ceilings or floors. e. Circuits shall not be overloaded. f. Fuses shall be sized correctly and not bridged out. g. Every public hall and stairway in every multifamily dwelling shall be adequately lighted at all times. h. All electric wiring, devices, appliances and fixtures shall be installed and maintained in accordance with the National Electrical Code. (2) Electrical outlets. Every habitable room shall contain at least two separate duplex convenience outlets. Outlets shall be located to reasonably provide service to appliances in different parts of the same room. Duplex convenience outlets, as herein provided, which may be lacking in single-family dwellings otherwise meeting the provisions of this article, shall be installed no later than one year from the passage of the ordinance from which this article is derived. (3) Electrical fixtures. At least one fixed in place ceiling or wall type electric light fixture shall be provided in every bedroom, toilet room, bathroom, laundry room, furnace room, public hall, basement or any other area in which artificial light is required for the safety and welfare of the occupants. A switched wall receptacle shall be acceptable in a bedroom, living room or den. (p) Plumbing standards. (1) General. a. Every dwelling unit shall be connected to the town water supply and/or sanitary sewer system where they are available, unless a private water supply and sanitary sewer system for each house is approved by the county health department. b. All plumbing, water closets and other plumbing fixtures in every dwelling or dwelling unit shall be installed and maintained in good working condition and repair and in accordance with the requirements of this article and the state plumbing code. c. All plumbing shall be so maintained and used as to prevent contamination of the water supply through cross connections or back siphoning. d. All plumbing fixtures shall be tied to a sanitary sewer system. e. All fixtures shall be in proper working condition with no leaks existing. f. No fixtures shall be cracked, broken or badly chipped. g. All water piping shall be protected from freezing by proper installation in enclosed or concealed areas or by such other means as approved by the state building codes. h. At least one two-inch minimum size main plumbing vent shall be properly installed for each building. i. Soil and water lines shall be properly supported with no broken or leaking lines. j. Access to all bathrooms shall be through a weathertight and heated area. k. Every dwelling unit shall contain, within a room which affords privacy, a toilet, lavatory basin and either a bathtub or shower in good working condition which shall be properly connected to both hot and cold water lines and to the public sanitary sewer or to an approved sewage disposal system. The floor of such room shall be made impervious to water to prevent structural deterioration and any development of unsanitary conditions. l. Sewer lift pumps and tanks shall be maintained in good working condition. (2) Water-heating unit. Every dwelling or dwelling unit shall have supplied a water-heating unit which has been listed by a testing agency and is properly installed, operated and maintained in safe and good working condition, and is properly connected to the bathtub or shower, sink and lavatory basin, as required in this article. Such water-heating unit shall be capable of automatically heating water to a temperature of 120 degrees Fahrenheit and capable of meeting normal demands at every required outlet. All gas-fired water heaters shall be vented to the outside. (q) Painting. Effective January 1, 1995, all exterior surfaces of buildings and structures not inherently resistant to deterioration shall be treated with a protective coating, such as paint or other suitable preservative, with sufficient frequency to prevent deterioration. All such portions shall be cleaned and free of flaking, loose or defective surfacing materials prior to painting or coating. All interior loose or peeling wall covering or paint shall be removed and the exposed surface shall be placed in a smooth and sanitary condition. No paint shall be used for interior painting of any dwelling or dwelling unit unless the paint is free from any lead pigment. Paint chips or paint dust shall not be left on interior or exterior surfaces of the dwelling. (r) Fire and safety standards. (1) Fire extinguishing equipment. All fire extinguishing equipment required by the town's laws, ordinances and regulations shall be provided and maintained in an operable condition. (2) Smoke detector. All dwellings and dwelling units shall be equipped with a smoke detector (battery operated or 110 volt) which has been listed by a testing agency (such as Underwriters Laboratories). All smoke detectors shall be located on or near the ceiling of the room wherein it is located and shall be installed in accordance with the manufacturer's instructions and maintained in proper working condition. Single- or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4, and in dwellings not regulated in Group R occupancies, regardless of occupant load, at all of the following locations: a. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. b. In each room used for sleeping purposes. c. In each story within a dwelling, including basements and cellars, but not including crawl spaces and uninhabitable attics in dwellings or dwelling units with split level and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level provided that the lower level is less than one full story below the upper level. (3) Carbon monoxide detector. All dwelling and dwelling units having a fossil-fuel burning heater, appliance, or fireplace and in any dwelling unit having an attached garage shall be equipped with a carbon monoxide detector which has been listed by a testing agency, and such detector shall be installed outside of each sleeping area inside the dwelling. (4) Fire alarm systems. All fire alarm systems required by the laws, ordinances and state building code shall be provided and maintained in an operable condition. (5) Flammable liquids. The use of gasoline stoves or other similar fuel-burning appliances using highly flammable liquids, and the use of portable kerosene stoves or other similar fuel-burning portable appliances, for cooking is prohibited. The occupant of any dwelling or dwelling unit shall not have or store flammable liquids or gas or any combustible material in a quantity greater than that permitted by the state building codes. (6) Abandoned iceboxes. The doors shall be removed from all iceboxes, refrigerators and other large airtight containers which are abandoned and which are accessible to children, unless the door or lock can be released or opened from the inside. (7) Lead abatement. The county health department is responsible for investigating all cases.
(Code 2000, § 8-40; Ord. No. 2013-26, 9-17-2013)
Ask a question about Wake Forest law
Corpus searches the Wake Forest sections it holds and shows the ones that match, with their citations. Free, no sign-in.