Sec. 16-108. - National electrical code; supplemental rules.

The following rules are intended to apply to permanent buildings or structures covered by the National Electrical Code: (1) Reserved. (2) All permanent buildings, wherever situated, which are required to have an emergency system power source by the state building code shall have the service entrance conductors enclosed in approved raceway; and in addition to the above, all portions of the required emergency lighting system for the entire building shall be wired in metal raceway, nonmetallic raceways encased in not less than two (2) inches of concrete, mineral-insulated metal-sheathed cable, or type MC cable as permitted by the city's electrical code. The total area of any specific place of assembly shall include the area of balconies and the area of connecting rooms with movable partitions. *Exception: Sound equipment, communication circuits, class two (2) and class three (3) remote control and signal circuits, and fire protection signalling circuits as permitted in the National Electrical Code. (3) Each individual gasoline pump, dispenser, lighting standard or other electrical devices located where gasoline or other volatile flammable liquids or liquefied flammable gases are transferred to the fuel tank of any motor vehicle shall be supplied through an individual rigid metal conduit. The above is not intended to prohibit the consolidation of such individual conduits outside of the hazardous areas, or consolidation within an approved junction box flush with the dispensing island surface. (4) Service equipment shall not be located in any attic, clothes closet, kitchen storage cabinet, bathroom, toilet room or coal or trash bin. (5) All panelboards which have spare pole spaces or space over-current devices and are set flush in masonry or finished walls shall be provided with at least one (1) one-inch approved raceway or other equivalent provision for future extension. Such raceways, when required, shall be installed to the basement, crawl space, accessible ceiling space or attic, or to a junction box in the ceiling or side wall at the ceiling line.

(Code 1962, § 8-57; Ord. of 8-28-84, § 1)

Ask a question about Wilmington law

Corpus searches the Wilmington sections it holds and shows the ones that match, with their citations. Free, no sign-in.