20.08.282 Section 303.2 Amended; Addition to a Group E Occupancy.

Section 303.2 to the International Existing Building Code is amended to read as follows: 303.2 Addition of a Group E Occupancy. Where an addition is added to an existing Group E occupancy located in an area where the shelter design wind speed for tornados is 250 mph in accordance with Figure 304.2(1) of ICC 500 and the occupant load in the addition is 50 or more, the addition shall have a storm shelter constructed in accordance with ICC 500, except Sections 702.2.3 and 702.2.4. Exceptions: (1) 1. Group E day care facilities. (2) 2. Group E occupancies accessory to places of religious worship. (3) 3. Buildings meeting the requirements for shelter design in ICC 500. ().

(Ord. 21819 §7; December 15, 2025)