§ 21.05.430 — Section 602 Amended; Heating Facilities
Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 21.05.430
Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/b225437d-dbdc-4388-a70f-026f2971d3da
21.05.430 Section 602 Amended; Heating Facilities.
Section 602 of the International Property Maintenance Code is amended to read as follows: SECTION 602 - HEATING FACILITIES 602.1 Facilities required. Heating facilities shall be provided in structures as required by this section. 602.2 Residential occupancies. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70°F. at a point between three and five feet above the floor level, under local outdoor winter design conditions as specified in the ASHRAE Handbook, as referenced in the International Mechanical Code, as adopted by the City. Cooking appliances shall not be used to provide space heating to meet the requirements of this section. Exception: In months when the average monthly temperature is below 30°F, a minimum temperature of 68°F shall be maintained. 602.3 Heat supply. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70°F from October 1 through April 30 of each year at a point between three and five feet above the floor level, under local outdoor winter design conditions as specified in the ASHRAE Handbook, as referenced in the International Mechanical Code, as adopted by the City. Such facilities shall be installed and maintained in a safe condition and in accordance with all other applicable laws. Unvented fuel-burning heaters are not permitted. All heating devices or appliances shall be of an approved type. Exceptions: (1) When the outdoor temperature is below the winter outdoor design temperature for the locality, maintenance of the minimum room temperature shall not be required provided that the heating system is operating at its full design capacity. (2) In months when the average monthly temperature is below 30°F, a minimum temperature of 68°F shall be maintained. 602.4 Room temperature measurement. The required room temperatures shall be measured 3 feet above the floor near the center of the room and 2 feet inward from the center of each exterior wall.
(Ord. 20258 §4; October 19, 2015: prior Ord. 19349 §43; March 1, 2009)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.