22.08.050 Grounding.

Every mast must be solidly grounded for protection against lightning discharge, using a ground conductor not smaller than No. 10 AWG copper wire or its approved equivalent, connected with an approved clamp to a one-half inch by eight foot copper-weld or equivalent ground rod. The ground shall be located a minimum of two feet from any foundation or other underground structure and shall be driven vertically downward until the top is from three to six inches below the surface of the ground. The ground conductor leading from the house or other support structure shall be buried to a depth of six inches. Where the above-described artificial ground is impractical, the Building Official may authorize an alternate method of grounding.

(Ord. 9031 §5; June 6, 1966: prior Ord. 5238; May 26, 1952)