25.06.070 Section 107 Amended; Construction Documents.

Section 107 of the International Mechanical Code is amended to read as follows: 107 Construction documents. When required by the Code Official for the enforcement of any provisions of this code, plans and specifications for the installation of mechanical systems or fuel gas systems shall be designed and prepared by an engineer or architect licensed by the state to practice as such and shall be filed with the Code Official and approved before the issuance of any permit. A sealed plan is required when the building has an occupancy load of twenty persons, is 5,000 feet in floor space, or has a wall thirty-five feet in height. One set of plans and specifications may be filed for review, provided that no fewer than three sets of corrected plans and specifications are to the applicant, and the other set shall be retained by the Code Official. When the plans and specifications do not comply with the provisions of this code or the Lincoln Fuel Gas Code, the necessary changes or revisions shall be made thereto. Every plan shall be a print or other type of plan approved by the Code Official. The information contained on the plans shall be clearly legible and specifically indicated. No plan shall be a scale smaller than one-eighth inch per foot. Specifications, legibly and definitely stated, shall be included either on the plan or on separate sheets. The approval of any plans or specifications shall not be construed to sanction any violation of this code, the Lincoln Fuel Gas Code, or any other Lincoln ordinance. No person shall deviate materially from any approved plans or specifications or fail, neglect, or refuse to comply therewith, unless permission to do so has been obtained from the Code Official and subject to architect or engineer approval, where applicable. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 68°F at a point between three and five feet above the floor level, under local outdoor winter design conditions as specified in ASHRAE Handbook. The above temperature shall be measured in the approximate center of all habitable rooms, on the story where the thermostat is located. With central forced air systems, the furnace blower shall be in constant operation for a minimum of two hours preceding temperature readings. Where air conditioning is provided, the cooling system shall be capable of maintaining a temperature of 78°F as measured in a manner the same as for heating. The plans or specifications shall show the following: (1) a. Layout for each floor with dimensions of all working spaces and a legend of all symbols used. (2) b. Location, size, and material of all piping. (3) c. Location, size, and materials of all air ducts, air inlets, and air outlets. (4) d. Location of all fans, furnaces, boilers, absorption units, refrigerant compressors and condensers, and the weight of all pieces of such equipment weighing 200 pounds or more. (5) e. Rated capacity or horsepower of all furnaces, heat exchanges, blower fans, refrigerant compressors, and absorption units. (6) f. Location, size, and material of all combustion product vents and chimneys. (7) g. Location and area of all ventilation and combustion air openings and ducts. (8) h. Location of all air dampers and fire and smoke devices. (9) i. First sheet of each set of plans and specifications shall show the address of the proposed work and the name and address of the owner or lessee of the premises. (10) j. Plans and specifications shall be of sufficient clarity to show that the proposed installation will conform to the provisions of this code and of all applicable laws, ordinances, rules, regulations, and orders. ().

(Ord. 21815 §4; December 15, 2025)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.