8.08.230 Body Art Establishment; Requirements for Sterilizing Instruments and Jewelry.

(a) All non-disposable instruments used for body art shall be cleansed and sterilized after each use. Autoclave sterilization shall be conducted for the cycle of time and corresponding operating pressure recommended by the manufacturer of the autoclave. Sanitizers used in the cleaning process must have demonstrated tuberculocidal activity, as indicated by the product label, and be registered with the U.S. Environmental Protection Agency. (b) Jewelry used for a new body piercing must be sterilized with a liquid chemical sterilant approved by the Health Director or as required by the product label. Jewelry used in healed body piercing does not have to be sterilized, but must be used according to the product label. (c) Instruments that are to be autoclaved must be packed in single use paper peel-packs or other containers designed for sterilizing instruments and marked with the expiration date. The expiration date shall not exceed ninety days from the date autoclaved. (d) A log shall be kept to document the hours of autoclave operation. (e) All sterilized instruments shall remain stored in sterilized containers until just prior to performing a body art procedure. Where several instruments are sterilized at the same time in the same container, such as in a single use setup, once the container is opened, any instruments not used immediately in a procedure must be resterilized. (f) Every batch of sterilized equipment shall be monitored for sterilization by use of a heat sensitive indicator that is capable of indicating approximate time and temperature achieved. In addition to the indicator requirements, spore destruction tests shall be performed to prove that autoclaves are capable of attaining the minimum operating standards. Spore tests shall be performed at a minimum of once for each autoclave every thirty days and shall be verified through an independent laboratory. (g) Autoclaves shall be cleaned at the frequency recommended by the manufacturer. Autoclaves shall be serviced at the frequency recommended by the manufacturer. A copy of the manufacturer's instructions for cleaning and servicing the autoclave must be maintained in operator’s file. (h) All clean or packaged sterilized instruments and supplies shall be stored in clean, dry closed cabinets, tightly covered containers, or in such a way that they remain sterile until used. (i) Prepackaged sterilized instruments shall not be used past the manufacturer's expiration date.

(Ord. 19732 §4; June 25, 2012: prior Ord. 17999 §19; May 20, 2002)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.