Sec. 54-46. - Same—Test equipment.
(a) All pools shall provide test equipment capable of accurately measuring free chlorine, combined chlorine, total chlorine, pH, calcium hardness, cyanuric acid (where applicable) and total alkalinity. (b) Chlorine/bromine test kit, DPD (Diethyl-P-Phenylene Diamine) test kit, or FAS-DPD (Ferrous Ammonium Sulfate—Diethyl-P-Phenylene Diamine) test kit shall be used. Where chlorine is used, a scale of 1—10 ppm shall be used to measure the free and combined chlorine residuals. (c) pH (hydrogen ion) test equipment shall be capable of measuring pH at a range of 7.0 to 8.0, accurate to the nearest 0.2 pH unit. (d) The alkalinity test range shall be at least 60 to 400 ppm as CaCO3. (e) Where cyanurates are used, a test kit to measure the cyanuric acid concentration shall be provided. It shall permit readings to at least 100 ppm with maximum increments of 25 ppm. (f) Additional test equipment shall be provided, as necessary, to accurately measure any and all chemicals, compounds or additives to the pool water to insure compliance with established parameters.
(Code 1980, § 54-46; Ord. No. 33770, § 11, 12-19-95; Ord. No. 37382, § 19, 5-23-06)