§ 52.125 SIZE AND SLOPE.

The size and slope of the building connection shall be subject to the approval of the Public Works Director, but in no event shall the diameter be less than four inches; and the slope of the four inch pipe shall in no case be less than one-fourth inch per foot. Six inch pipe may be laid at a slope of one-eighth inch per foot. Pipe larger than the minimum size herein specified shall be used when and as the size of structure, numbers and kinds of fixtures to be drained or other conditions may make it necessary to provide for adequate and proper flow. Building connections with diameters greater than or equal to eight inches arc considered sewer mains and shall meet all applicable requirements of the standard specifications of the Department and this chapter and the requirements of the WSPCD, including, providing manholes at all bends and changes in direction and at the point of connection with the public sewer. (Ord. passed 1-17-95; Am. Ord. 1- 7-25) Penalty, see § 52.999