§ 450-10 — Ventilation

Code of the City of Camden, New Jersey · Camden City Code § 450-10

Corpus is an independent public-information project, not the official City of Camden website. Stable reference: corpuslaw.us/code/5bfa0433-6bfb-416c-948d-e155274db4bc

§ 450-10: Ventilation.

A. Means of ventilation shall be provided for every habitable room. Such ventilation may be provided either by an easily operable window or skylight having an openable area of at least 50% of the minimum window area or minimum skylight area as required in § 450-9A or by other means acceptable to the Administrative Authority which will provide at least two air changes per hour. B. Means of ventilation shall be provided for every bathroom or water closet compartment. Such ventilation may be provided either by an easily operable window or skylight having an openable area of at least 50% of the minimum window area or minimum skylight area as required in § 450-9A or by other means acceptable to the Administrative Authority which will provide at least six air changes per hour.