§ 620-106 — Fire escapes; smoke and carbon monoxide detectors and fire alarms

Code of the City of Camden, New Jersey · Camden City Code § 620-106

Corpus is an independent public-information project, not the official City of Camden website. Stable reference: corpuslaw.us/code/99a7f282-c3c4-48b0-b56b-2882495a11d7

§ 620-106: Fire escapes; smoke and carbon monoxide detectors and fire alarms.

A. Smoke and carbon monoxide detectors. (1) Every dwelling unit, including single-family dwelling units available for rent for residential purposes, shall have smoke detectors as follows: (a) Outside of each bedroom within 10 feet of each bedroom door. (b) Within 10 feet of each primary exit. (c) In all common areas, such as vestibules and hallways, that are shared by residential tenants in a structure containing two dwelling units or more. (2) It shall be the responsibility of the property owner to maintain all such required smoke detectors in good order at all times. (3) Carbon monoxide detectors. All occupied residential properties and multiple dwellings shall be equipped with carbon monoxide detectors installed outside each separate sleeping area. Carbon monoxide detectors are required in residential building even though they may already have a fire alarm system. This is consistent with life safety codes and standards recommendations. Carbon monoxide detectors must meet and conform to UL 2034 and be installed in accordance with NFPA 720 and manufacturer's instructions. Carbon monoxide detectors must be maintained in good operating condition and in accordance with manufacturer's instructions. Battery backup for carbon monoxide devices is also required. (4) It shall be the responsibility of the property owner to maintain all such required carbon monoxide detectors in good working order at all times. B. Fire escapes and fire alarms. (1) Every establishment, dwelling or structure containing two dwelling units or more, or two rooming units or more, or any combination of a dwelling unit(s) and a rooming unit(s), wherein any unit above the second floor is occupied or available for occupancy, shall require either a fire escape and a fire alarm system or any other second means of egress and said fire alarm system, either of which combination must meet the approval of the proper officials referred to by the Public Officer. (2) The fire alarm system or devices and the fire escape and/or second means of egress required shall be equipped and installed pursuant to the specifications required by the Building and/or Fire Official's offices. Periodic testing shall be required in accordance with the regulations of and approved by the proper officials referred to by the Public Officer. (3) The fire escape and fire alarm system and/or the second means of egress and fire alarm system required hereunder shall be maintained in good working order at all times.

[Added 5-25-2005 by Ord. No. MC-4183 ]

Ask a question about Camden law

Corpus searches the Camden sections it holds and shows the ones that match, with their citations. Free, no sign-in.