§ 620-79: Exterior of structures.

A. The exterior of a structure shall be maintained in good repair, structurally sound and sanitary, so as not to pose a threat to the public health, safety or welfare. B. Protective treatment. All exterior surfaces, including but not limited to doors, door and window frames, cornices, porches, trim, balconies, decks and fences shall be maintained in good condition. Exterior wood surfaces, other than decay-resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking and chipped paint shall be eliminated and surfaces repainted. The removal of lead-based paint shall be performed pursuant to the applicable provisions of state law. All siding and masonry joints as well as those between the building envelope and the perimeter of windows, doors, and skylights shall be maintained weather-resistant and watertight. All metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion, and all surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement. C. Premises identification. Buildings shall have approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of four inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). D. Structural members. All structural members shall be maintained free from deterioration and shall be capable of safely supporting the imposed dead and live loads. E. Foundation walls. All foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests. F. Exterior walls. All exterior walls shall be free from holes, breaks, and loose or rotting materials, and maintained weatherproof, and properly surface-coated where required to prevent deterioration. G. Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. H. Decorative features. All cornices, belt courses, corbels, terra-cotta trim, wall facings and similar decorative features shall be maintained in good repair with proper anchorage and in a safe condition. I. Overhang extensions. All overhang extensions, including but not limited to canopies, marquees, signs, metal awnings, fire escapes, standpipes, and exhaust ducts, shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. When required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials such as paint or similar surface treatment. J. Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads. K. Chimneys and towers. All chimneys, cooling towers, smokestacks, and similar appurtenances shall be maintained structurally safe and sound and in good repair, All exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment. L. Residential stairs and railings. (1) Interior stairs of every structure used for human habitation shall be structurally sound and free of defect. (2) Handrails or banisters shall be provided for all stairs, balconies or fire escapes. M. Every window, other than a fixed window, shall have standard-type glass and shall be easily openable and capable of being held in position by the window hardware. Additionally, all such windows used for this purpose shall be covered by blinds, drapes, shades or other permanent fixtures rendering the window opaque to the public view, except that cardboard, wood, paper or other such temporary coverings shall not be permitted. N. Glazing. All glazing materials shall be maintained free from cracks and holes. O. Openable windows. Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware. P. Screens. Properly fitting screens in good repair shall be supplied for each exterior rear door and window of each dwelling unit or rooming unit. Such screens shall have a mesh of not less than No. 16. Screens shall not be required in rooms deemed by the Public Officer, pursuant to regulation, to be located sufficiently high to be free of mosquitoes, flies and other undesirable insects or otherwise protected from serving as a means of access for infestation. In establishments subject to licensing and in all buildings where janitor service is required pursuant to § 620-83A, screens shall be installed and maintained by the owner or operator on all rear doors and windows from May 1 to October 15 of each year. Q. Doors. All exterior doors, door assemblies and hardware shall be maintained in good condition, Locks at all entrances to dwelling units, rooming units and guest rooms shall tightly secure the door. Locks on means of egress doors shall be in accordance with § 620-108C. R. Basement hatchways. Every basement hatchway shall be maintained to prevent the entrance of rodents, rain and surface drainage water. S. Guards for basement windows. Every basement window that is openable shall be supplied with rodent shields, storm windows or other approved protection against the entry of rodents.

[Amended 6-24-2008 by Ord. No. MC-4403 ]

Ask a question about Camden law

Corpus searches the Camden sections it holds and shows the ones that match, with their citations. Free, no sign-in.