For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 620-89 — Occupancy limitations

Code of the City of Camden, New Jersey · Camden City Code § 620-89

Corpus is an independent public-information project, not the official City of Camden website. Stable reference: corpuslaw.us/code/bacc7ea0-7404-4c86-8cf2-93711793fcd3

§ 620-89: Occupancy limitations.

A. Privacy. Dwelling units, hotel units, rooming units and dormitory units shall be arranged to provide privacy and be separate from other adjoining spaces. B. Occupancy by disabled persons. Occupancy by a disabled person or persons requiring special care or persons requiring nursing home care in lodging houses, boardinghouses (Class A) and mixed-occupancy dwellings is hereby prohibited. C. Determination of occupant's disability. Where the Public Officer has reason to believe that an occupant of an establishment subject to licensing either requires special care or is disabled, the Public Officer may require that the occupant procure, within 48 hours, a physician's certificate attesting to the mental or physical condition of said occupant as it relates to the category in which the occupant is classified, and if the Public Officer shall determine that said person requires special care and is thereby prohibited from residing in a lodging house or boardinghouse (Class A) or is disabled and thereby prohibited from residing in any lodging house or boardinghouse, then the licensee of said premises shall be ordered to remove said occupant from the premises no later than five days after the issuance of the order. D. Minimum room widths A habitable room, other than a kitchen, shall not be less than seven feet (2,134 mm) in any plan dimension. Kitchens shall have a clear passageway of not less than three feet (914 mm) between counterfronts and appliances or counterfronts and walls. E. Minimum ceiling heights. (1) Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a clear ceiling height of not less than seven feet (2,134 mm). (2) Exceptions: (a) In one- and two-family dwellings, beams or girders spaced not less than four feet (1,219 mm) on center and projecting not more than six inches (152 mm) below the required ceiling height. (b) Basement rooms in one- and two-family dwellings occupied exclusively for laundry, study or recreation purposes, having a ceiling height of not less than six feet eight inches (2,033 mm) with not less than six feet four inches (1,932 mm) of clear height under beams, girders, ducts and similar obstructions. (c) Rooms occupied exclusively for sleeping, study or similar purposes and having a sloped ceiling over all or part of the room, with a clear ceiling height of at least seven feet (2,134 mm) over not less than 1/3 of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a clear ceiling height of five feet (1,524 mm) or more shall be included. F. Bedroom requirements. Every bedroom shall comply with the requirements of Subsection F(1) through (5). (1) Area for sleeping purposes. Every bedroom occupied by one person shall contain at least 70 square feet (6.5 mz) of floor area, and every bedroom occupied by more than one person shall contain at least 50 square feet (4.6 mz) of floor area for each occupant thereof. (2) Access from bedrooms. Bedrooms shall not constitute the only means of access to other bedrooms or habitable spaces and shall not serve as the only means of egress from other habitable spaces. Exception: units that contain fewer than two bedrooms. (3) Bathrooms and water closets. (a) Bathroom and water closet facilities which are completely enclosed shall be provided for occupants, in a room which affords privacy to the occupant thereof. All bathrooms shall be provided with inside locks. (b) Accessibility. Every bedroom shall have access to at least one water closet and one lavatory without passing through another bedroom. Every bedroom in a dwelling unit shall have access to at least one water closet and lavatory located in the same story as the bedroom or an adjacent story. (4) Prohibited occupancy. Cellars, kitchens and uninhabitable spaces shall not be used for sleeping purposes. (5) Other requirements. Bedrooms shall comply with the applicable provisions of this chapter, including but not limited to the light, ventilation, room area, ceiling height and room width requirements of this article; the plumbing facilities and water-heating facilities requirements of Article V; the heating facilities and electrical receptacle requirements of Article VI; and the smoke detector and emergency escape requirements of Article VII. G. Overcrowding. Dwelling units shall not be occupied by more occupants than permitted by the minimum area requirements of the table below: Minimum Area(square feet) Space | 1 to 2 Occupants | 3 to 5 Occupants | 6 or More Occupants Living rooma,b | No requirements | 120 | 150 Dining rooma,b | No requirements | 80 | 100 Kitchenb | 50 | 50 | 60 Bedrooms | Shall comply with § 620-89F For SI: 1 square foot = 0.093 m2 a | See § 620-89G(2) for combined living room/dining room spaces. b | See § 620-89G(1) for limitations on determining the minimum occupancy area for sleeping purposes. (1) Sleeping area. The minimum occupancy area required by the table above shall not be included as a sleeping area in determining the minimum occupancy area for sleeping purposes. All sleeping areas shall comply with Subsection F. (2) Combined spaces. Combined living room and dining room spaces shall comply with the requirements of the table above if the total area is equal to that required for separate rooms and if the space is located so as to function as a combination living room/dining room. H. Efficiency unit. Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements: (1) A unit occupied by not more than two occupants shall have a clear floor area of not less than 220 square feet (20.4 mz). A unit occupied by three occupants shall have a clear floor area of not less than 320 square feet (29.7 mz). These required areas shall be exclusive of the areas required by Subsection H(2) and (3). (2) The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a clear working space of not less than 30 inches (762 mm) in front. Light and ventilation conforming to this chapter shall be provided. (3) The unit shall be provided with a separate bathroom, containing water closet, lavatory and bathtub or shower. (4) The maximum number of occupants shall be three. I. Food preparation. All spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store, prepare and serve foods in a sanitary manner. There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse, including facilities for temporary storage. J. Standards to be cumulative. Nothing contained in § 620-89 shall be construed as permitting occupancy in violation of any other occupancy standards, all occupancy standards being cumulative and not in the alternative. K. Residential superficial floor area requirements (dwelling unit): (1) Every dwelling unit shall contain a minimum superficial floor area of 150 square feet for the initial occupant, 250 square feet for two occupants, 350 square feet for three occupants and 100 square feet for each occupancy thereafter, except that, for the purposes of the section, children under one year of age shall not be counted as occupants. In accordance with the definition of "floor area, superficial," the minimum height overall of the area to be included in this calculation shall be seven feet from floor to ceiling. L. In addition to the above-set-forth minimum superficial floor area requirements, in the case of all dwelling units where there are more than two occupants, there shall be, in addition to the above, a minimum of 120 square feet of space that shall be for living purposes, where said occupants may congregate for recreation or other family functions. This space shall not be part of the bedroom area, bathroom area or kitchen area of said dwelling area unless it is physically separated therefrom by a partition or a wall in accordance with the Building Code of the City of Camden.

[Amended 10-12-2006 by Ord. No. MC-4226 ]

Ask a question about Camden law

Corpus searches the Camden sections it holds and shows the ones that match, with their citations. Free, no sign-in.