§ 675-10 — Interceptors and traps

Code of the City of Camden, New Jersey · Camden City Code § 675-10

Corpus is an independent public-information project, not the official City of Camden website. Stable reference: corpuslaw.us/code/8c1ee481-acf4-4049-aad5-69f4ebdcab23

§ 675-10: Interceptors and traps.

A. Grease, oil and sand interceptors or traps shall be provided when, in the opinion of the Director of Public Works, or his duly authorized representative, they are necessary for the proper handling of liquid wastes containing grease in excessive amounts or any flammable wastes, sand and other harmful ingredients, except that such interceptors or traps shall not be required for private living quarters or dwelling units. Grease traps/interceptors shall not be required for residential users. B. No user may intentionally or unintentionally allow the direct or indirect discharge of any fats, oils, or greases into the City of Camden wastewater collection system in such amounts as to cause interference with the collection and treatment system, or as to cause pollutants to pass through the treatment works into the environment. Also see § 675-4 (Wastes Restricted from Public Sewer). C. All food service establishments shall be required to install a grease trap/interceptor, unless an exemption is granted pursuant to this article. D. All other commercial and/or industrial establishments shall be required to install a grease trap/interceptor when, in the reasonable opinion of the Director of Public Works, or his duly authorized representative, grease, flammable waste, oil and sand interceptors or oil reclaimers are necessary due to the type of activity/use of the property. E. The following regulations and requirements shall apply to all external grease traps where such grease traps are installed or required to be installed: (1) All interceptors or traps shall be of a type and capacity approved by the Director of Public Works, provided that they produce an effluent conforming to the provisions of this article, and shall be located as to be readily and easily accessible for cleaning and inspection. (2) Grease and oil interceptors or traps shall be constructed of impervious materials capable of withstanding abrupt and extreme changes in temperature. They shall be of substantial construction, watertight and equipped with easily removable covers which, when bolted in place, shall be gastight and watertight. The design and pertinent data shall be submitted to the Director of Public Works, or his duly authorized representative for review and approval prior to construction or installation. Separators must be constructed entirely on the property of the owner. (3) Where installed, all grease, oil and sand interceptors or traps shall be maintained by the owner, at his expense, in continuously efficient operation at all times. (4) Grease traps and interceptors shall be installed in accordance with the New Jersey Uniform Construction Code 5:23, Subchapter 3.15, Plumbing Subcode. (5) Grease traps shall have the grease retention capacity as indicated in the Plumbing Subcode, as adopted in N.J.A.C. 5:23-3.15. (6) In all cases, grease traps shall conform to the Plumbing and Drainage Institute Standards (PDI). (7) It is the responsibility of the establishment owner, lessee or assignee to carry out all proceedings necessary to have any and all grease interceptors opened and ready for inspection and to see that the equipment is put back in proper operation after the inspection. All inspections will be conducted by the Director of Public Works, or his duly authorized representative. (8) Forms for periodic inspections will be furnished by the owner, lessee or assignee and posted as close as possible to the interceptor to which it applies. The form shall be protected from soiling. In those instances where the interceptor is chemically treated, the method and chemical of such treatment shall be approved by the Director of Public Works. Any proposed chemical changes shall be furnished to the Director of Public Works for approval. Copies of maintenance and removal records shall be provided to the Director of Public Works within seven days of such occurrence. (9) The fee for inspection, as required in the schedule listed, will be the same as the plumbing fee in force at the time of the requested or required inspection. The minimum fee will include the first three interceptors at one location prepared and ready for inspection. Other interceptors that are prepared and ready for inspection at the same time, and are in excess of the first three units, will be inspected at an additional fee of 1/2 the minimum fee for each additional interceptor. The schedule for cleaning is as follows: Grease Capacity(pounds) | Maximum Inspection Intervals(months) Up to 60 | 6 months 60 and over | 4 months (10) The above schedule may be altered by the Director of Public Works if deemed necessary. The owner, lessee or assignee shall be notified, in writing, of any schedule change. (11) New facilities. Nonresidential facilities which are newly proposed or constructed, or existing facilities which will be expanded or renovated to include a facility generating fats, oils, or greases, where such facility did not previously exist, shall be required to design, install, operate and maintain a grease interceptor in accordance with locally adopted plumbing codes or other applicable ordinances. Grease interceptors shall be installed and inspected prior to issuance of a certificate of occupancy. (12) All existing nonresidential establishments without grease interceptors shall install grease interceptors and follow the inspection schedule as set forth. The existing food service establishments shall have 180 days from the effective date of this article to install a grease interceptor. (13) The Director of Public Works shall require all interceptors to be efficient in operation and may, at the expense of the owner, lessee or assignee, require independent laboratory tests to ascertain the concentration of grease being emitted from the effluent line of the unit. All grease traps shall be cleaned in accordance with the foregoing schedule and the City provided with a bill or receipt from a licensed grease and waste disposal company or qualified recycling company. Disagreeable odors shall require deodorants to combat said offensive odors. (14) Any person violating any of the provisions of this section shall be subject to a written warning for the first violation, a $1,000 civil penalty for the second violation, a $1,500 civil penalty for the third violation, and a $2,000 civil penalty for the fourth violation within a two-year period. Consistent violations will result in a $500 increase in civil penalty and may result in termination of service.

[Amended 8-13-1981 by Ord. No. MC-1766 ; 7-8-2014 by Ord. No. MC-4840 ]

Ask a question about Camden law

Corpus searches the Camden sections it holds and shows the ones that match, with their citations. Free, no sign-in.