§ 207-6 — Operation and maintenance requirements
Code of the City of Clifton, New Jersey (Code 2026-10-20) · Clifton City Code § 207-6
Corpus is an independent public-information project, not the official City of Clifton website. Stable reference: corpuslaw.us/code/2d86fb07-cef6-499f-9478-492ee90bfc59
§ 207-6: Operation and maintenance requirements.
A. The public shall only be permitted access to that portion of a coin-operated or self-service dry-cleaning machine which is necessary for use of those machines. The remaining portion of each machine shall be separated from the customer area by a partition in which there are grilles or similar ventilation devices. This partitioned off area shall be called the "maintenance area." The access door to the maintenance area shall be self-closing and locked to prevent access by the public. B. No person other than the license holder and an employee or representative of the license holder shall enter the maintenance area. C. The maintenance area shall not be interconnected with an area containing heating devices requiring air for combustion, such as gas dryers, water heaters and comfort heating devices. D. Heating devices requiring air for combustion shall be installed in such a fashion as to obtain air for combustion from the outside atmosphere. E. Ventilation of establishments shall be effected by the drawing of air from the customer area through grilles or other openings in the partition by means of an exhaust fan or fans operating in the maintenance area. Exhaust fans shall have a rated capacity of 400 cubic feet per minute (c.f.m) per machine for normal use and 1,000 cubic feet per minute for use in emergencies. The rated capacities of exhaust fans shall appear on this equipment or its nameplate. If air is being constantly exhausted as a built-in feature of the equipment, the rated capacity of the fan can be reduced by the amount so exhausted. F. Air shall be replenished at a temperature not less than 60º F. as quickly as it is exhausted from the customer area. G. Each automatic coin-operated or self-service dry-cleaning machine shall be equipped with an exhaust system that maintains a minimum of 100 feet per minute velocity through the loading door whenever the door is open. The duct work connections to this system shall be sealed (soldered or taped) and the discharge outlet extended to a minimum height of five feet above the roofline and shall be located so that the effluent may not reenter the premises. H. The terminal of any exhaust shall be at least five feet from any window or ventilating opening if said ventilating window or ventilating opening lies on the same plane as the exhaust terminal; when the ventilating windows or other ventilating openings lie on a plane which faces in the direction of the exhaust terminal, such terminal shall be at least 10 feet away from the same. I. A concrete dyke or metal pan or similar facility shall be installed at the location of each machine to collect and contain spillage. This facility shall be constructed of a material impervious to the solvent used. J. The floor covering in the customer area shall be made of a material resistant to the solvents used in such machines. K. All establishments shall meet the requirements of all established state and local laws, codes and regulations, including but not limited to air pollution, electrical wiring, plumbing, fire prevention, waste disposal, sanitation, solvent storage, food or beverage vending, hours of operation and presence of an attendant.
Ask a question about Clifton law
Corpus searches the Clifton sections it holds and shows the ones that match, with their citations. Free, no sign-in.